Taiki Magome

Taiki Magome

Auto-generated profile, based on publicly available information

Taiki Magome

Graduate Division of Health Sciences, Komazawa University, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YMYu Murakami
Yu Murakami
TMTaiki Magome
Taiki Magome
KMKazuki Matsumoto
Kazuki Matsumoto
TSTomoharu Sato
Tomoharu Sato
YYYasuo Yoshioka
Yasuo Yoshioka
MOMasahiko Oguchi
Masahiko Oguchi
Although dose prediction for intensity modulated radiation therapy (IMRT) has been accomplished by a deep learning approach, delineation of some structures is needed for the prediction. We sought to develop a fully automated dose-generation framework for IMRT of prostate cancer by entering the patient CT datasets without the contour information into a generative adversarial network (GAN) and to compare its prediction performance to a conventional prediction model trained from patient contours. We propose a synthetic approach to translate patient CT datasets into a dose distribution for IMRT. The framework requires only paired-images, i.e., patient CT images and corresponding RT-doses. The model was trained from 81 IMRT plans of prostate cancer patients, and then produced the dose distribution for 9 test cases. To compare its prediction performance to that of another trained model, we created a model trained from structure images. Dosimetric parameters for the planning target volume (PTV) and organs at risk (OARs) were calculated from the generated and original dose distributions, and mean differences of dosimetric parameters were compared between the CT-based model and the structure-based model. The mean differences of all dosimetric parameters except for D98% and D95% for PTV were within approximately 2% and 3% of the prescription dose for OARs in the CT-based model, while the differences in the structure-based model were within approximately 1% for PTV and approximately 2% for OARs, with a mean prediction time of 5 seconds per patient. Accurate and rapid dose prediction was achieved by the learning of patient CT datasets by a GAN-based framework. The CT-based dose prediction could reduce the time required for both the iterative optimization process and the structure contouring, allowing physicians and dosimetrists to focus their expertise on more challenging cases.

1 April 2020 in Physica Medica
Verified
Journal Article
Open access
ISIori Sumida
Iori Sumida
TMTaiki Magome
Taiki Magome
Indra J DasIndra J Das
Indra J Das
HYHajime Yamaguchi
Hajime Yamaguchi
HKHisao Kizaki
Hisao Kizaki
KOKazuhiko Ogawa
Kazuhiko Ogawa
This study aims to investigate the feasibility of using convolutional neural networks to predict an accurate and high resolution dose distribution from an approximated and low resolution input dose. Sixty-six patients were treated for prostate cancer with VMAT. We created the treatment plans using the Acuros XB algorithm with 2 mm grid size, followed by the dose calculated using the anisotropic analytical algorithm with 5 mm grid with the same plan parameters. U-net model was used to predict 2 mm grid dose from 5 mm grid dose. We investigated the two models differing for the training data used as input, one used just the low resolution dose (D model) and the other combined the low resolution dose with CT data (DC model). Dice similarity coefficient (DSC) was calculated to ascertain how well the shape of the dose-volume is matched. We conducted gamma analysis for the following: DVH from the two models and the reference DVH for all prostate structures. The DSC values in the DC model were significantly higher than those in the D model (p < 0.01). For the CTV, PTV, and bladder, the gamma passing rates in the DC model were significantly higher than those in the D model (p < 0.002-0.02). The mean doses in the CTV and PTV for the DC model were significantly better matched to those in the reference dose (p < 0.0001). The proposed U-net model with dose and CT image used as input predicted more accurate dose.

28 October 2019 in Journal of Radiation Research
Verified
Journal Article
Open access
TMTakuya Mizutani
Takuya Mizutani
TMTaiki Magome
Taiki Magome
HIHiroshi Igaki
Hiroshi Igaki
AHAkihiro Haga
Akihiro Haga
KNKanabu Nawa
Kanabu Nawa
KNKeiichi Nakagawa
Keiichi Nakagawa
The purpose of this study was to predict the survival time of patients with malignant glioma after radiotherapy with high accuracy by considering additional clinical factors and optimize the prescription dose and treatment duration for individual patient by using a machine learning model. A total of 35 patients with malignant glioma were included in this study. The candidate features included 12 clinical features and 192 dose–volume histogram (DVH) features. The appropriate input features and parameters of the support vector machine (SVM) were selected using the genetic algorithm based on Akaike’s information criterion, i.e. clinical, DVH, and both clinical and DVH features. The prediction accuracy of the SVM models was evaluated through a leave-one-out cross-validation test with residual error, which was defined as the absolute difference between the actual and predicted survival times after radiotherapy. Moreover, the influences of various values of prescription dose and treatment duration on the predicted survival time were evaluated. The prediction accuracy was significantly improved with the combined use of clinical and DVH features compared with the separate use of both features (P < 0.01, Wilcoxon signed rank test). Mean ± standard deviation of the leave-one-out cross-validation using the combined clinical and DVH features, only clinical features and only DVH features were 104.7 ± 96.5, 144.2 ± 126.1 and 204.5 ± 186.0 days, respectively. The prediction accuracy could be improved with the combination of clinical and DVH features, and our results show the potential to optimize the treatment strategy for individual patients based on a machine learning model.


4 September 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
MNMasahiro Nakano
Masahiro Nakano
AHAkihiro Haga
Akihiro Haga
JKJun’iChi Kotoku
Jun’iChi Kotoku
TMTaiki Magome
Taiki Magome
YMYoshitaka Masutani
Yoshitaka Masutani
Keiichi NakagawaKeiichi Nakagawa
Keiichi Nakagawa
The purpose of this study is to introduce the new concept of a four-dimensional (4D) cone-beam computed tomography (CBCT) reconstruction approach for non-periodic organ motion in cooperation with the time-ordered chain graph model (TCGM) and to compare it with previously developed methods such as total variation-based compressed sensing (TVCS) and prior-image constrained compressed sensing (PICCS). Our proposed reconstruction is based on a model including the constraint originating from the images of neighboring time phases. Namely, the reconstructed time-series images depend on each other in this TCGM scheme, and the time-ordered images are concurrently reconstructed in the iterative reconstruction approach. In this study, iterative reconstruction with the TCGM was carried out with 90° projection ranges. The images reconstructed by the TCGM were compared with the images reconstructed by TVCS (200° projection ranges) and PICCS (90° projection ranges). Two kinds of projection data sets–an elliptic-cylindrical digital phantom and two clinical patients’ data–were used. For the digital phantom, an air sphere was contained and virtually moved along the longitudinal axis by 3 cm/30 s and 3 cm/60 s; the temporal resolution was evaluated by measuring the penumbral width of the air sphere. The clinical feasibility of the non-periodic time-ordered 4D CBCT image reconstruction was examined with the patient data in the pelvic region. In the evaluation of the digital-phantom reconstruction, the penumbral widths of the TCGM yielded the narrowest result; the results obtained by PICCS and TCGM using 90° projection ranges were 2.8% and 18.2% for 3 cm/30 s, and 5.0% and 23.1% for 3 cm/60 s narrower than that of TVCS using 200° projection ranges. This suggests that the TCGM has a better temporal resolution, whereas PICCS seems similar to TVCS. These reconstruction methods were also compared using patients’ projection data sets. Although all three reconstruction results showed motion related to rectal gas or stool, the result obtained by the TCGM was visibly clearer with less blurring. The TCGM is a feasible approach to visualize non-periodic organ motion. The digital-phantom results demonstrated that the proposed method provides 4D image series with a better temporal resolution compared to TVCS and PICCS. The clinical patients’ results also showed that the present method enables us to visualize motion related to rectal gas and flatus in the rectum.

1 January 2013 in BioMed Research International
Verified
Journal Article
Open access
PDF file
TMTaiki Magome
Taiki Magome
HAHidetaka Arimura
Hidetaka Arimura
YSYoshiyuki Shioyama
Yoshiyuki Shioyama
KNKatsumasa Nakamura
Katsumasa Nakamura
HHHiroshi Honda
Hiroshi Honda
HHHideki Hirata
Hideki Hirata
Objective. To develop a similar-case-based optimization method for beam arrangements in lung stereotactic body radiotherapy (SBRT) to assist treatment planners.Methods. First, cases that are similar to an objective case were automatically selected based on geometrical features related to a planning target volume (PTV) location, PTV shape, lung size, and spinal cord position. Second, initial beam arrangements were determined by registration of similar cases with the objective case using a linear registration technique. Finally, beam directions of the objective case were locally optimized based on the cost function, which takes into account the radiation absorption in normal tissues and organs at risk. The proposed method was evaluated with 10 test cases and a treatment planning database including 81 cases, by using 11 planning evaluation indices such as tumor control probability and normal tissue complication probability (NTCP).Results. The procedure for the local optimization of beam arrangements improved the quality of treatment plans with significant differences (P<0.05) in the homogeneity index and conformity index for the PTV, V10, V20, mean dose, and NTCP for the lung.Conclusion. The proposed method could be usable as a computer-aided treatment planning tool for the determination of beam arrangements in SBRT.