Wei Pang

Wei Pang

Auto-generated profile, based on publicly available information

Wei Pang

School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2019 in IEEE Access
Verified
Journal Article
Open access
XWXiaoyuan Wang
Xiaoyuan Wang
WPWei Pang
Wei Pang
PGPeng Gao
Peng Gao
XZXiaoxiao Zhao
Xiaoxiao Zhao
For the design of printed circuit board (PCB) winding, it is necessary to take into account the requirements of electromagnetic and manufacture technology of PCB winding, which directly affect the output power of the machine. In this paper, for axial flux permanent magnet generator (AFPMG) of a small wind power system, the unequal-width (UEW) winding is proposed for the aim of improving the output power of the generator. The design ideas and methods of unequal-width (UEW) winding are proposed in combination with manufacture technology of the PCB. The finite element analysis (FEA) model of machine is built. The analytical formulas of electromotive force (EMF) and winding loss are derived. Though the comparisons between reactance and impedance of PCB winding, the analytical formula of output power is simplified. These characteristics of the generator with traditional equal-width(EW) winding and proposed UEW winding are analyzed and compared in detail by FEA and analytical calculation. The result shows that the output power of the generator with UEW winding is improved largely. Finally, the validity of the FEA model and analysis method is verified by experiment of prototype machine, which provides the reference for the design of AFPMG with PCB winding.

26 June 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Xin LiXin Li
Xin Li
Ji LiangJi Liang
Ji Liang
HZHongxiang Zhang
Hongxiang Zhang
XYXing Yang
Xing Yang
HZHao Zhang
Hao Zhang
MZMenglun Zhang
Menglun Zhang
This paper reports an uncooled infrared (IR) detector based on a micromachined piezoelectric resonator operating in resonant and resistive dual-modes. The two sensing modes achieved IR responsivities of 2.5 Hz/nW and 900 μdB/nW, respectively. Compared with the single mode operation, the dual-mode measurement improves the limit of detection by two orders of magnitude and meanwhile maintains high linearity and responsivity in a higher IR intensity range. A combination of the two sensing modes compensates for its own shortcomings and provides a much larger dynamic range, and thus, a wider application field of the proposed detector is realized.

7 July 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
WCWeiwei Cui
Weiwei Cui
MZMenglun Zhang
Menglun Zhang
DZDaihua Zhang
Daihua Zhang
WPWei Pang
Wei Pang
HZHao Zhang
Hao Zhang
In this paper, we present a single-plate electro-wetting on dielectric (SEWOD) device by integrating an island-ground electrode (IG), which is surrounded by the driving electrodes and looks like an island. Both experiments and theoretical analysis have been conducted to investigate the performance of the IG-SEWOD device. The driving voltage of a fabricated IG-SEWOD has been measured to be 15 V, which is half of that of a floating SEWOD. The digital dynamic properties of the EWOD device are greatly enhanced due to the “double locking” effect and rapid residual charges elimination provided by the IG. The proposed EWOD device shows great potential in constructing advanced microfluidics platforms for bio-chemical detection and disease diagnosis.

1 June 2017
Verified
Conference Paper
Closed access
YWY. W. Wang
Y. W. Wang
CAC. Y. Ao
C. Y. Ao
ZHZ. P. Hui
Z. P. Hui
XYX. Yan
X. Yan
ZHZhen Hu
Zhen Hu
WPW. Pang
W. Pang
This paper reported a miniaturized sensitive gravimetric gas sensor based on film bulk acoustic resonator (FBAR). The sensitivity of the FBAR gas sensor was enhanced 10~20 times after coating with nanomaterials (metal organic frameworks (MOFs)). A facile coating process of MOFs on FBARs was disclosed for the first time. Furthermore, utilizing FBAR sensors as detectors was firstly demonstrated in a prototype of chromatographic instrument by facile hyphenation of FBAR with commercial separation column.

17 January 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HZHao Zhang
Hao Zhang
WPWei Pang
Wei Pang
EKEun Sok Kim
Eun Sok Kim
In this paper, micromachined longitudinal wave resonant mass sensors operating near 1 GHz in a liquid environment are investigated and characterized. Mass sensitivities of the film bulk acoustic resonator (FBAR) and high-tone bulk acoustic resonator (HBAR) microbalances with small size are measured to be 782.7 cm2/g (50 times larger than that of conventional bulky quartz crystal microbalance) and 9.3 cm2/g, respectively. Based on the mass sensitivities and frequency noise floor, the minimum detectable mass of the FBAR and HBAR are estimated to be 2.8 ng/cm2 and 11.9 ng/cm2 in liquid, respectively.

1 April 2009
Verified
Conference Paper
Closed access
SRShailesh Rai
Shailesh Rai
YSYing Su
Ying Su
ADAron Dobos
Aron Dobos
RKRichard Kim
Richard Kim
RRRichard Ruby
Richard Ruby
BOBrian Otis
Brian Otis
A temperature compensated 1.5 GHz FBAR-based frequency reference implemented in a 0.35 mum CMOS process is presented. The ultra-small form factor and low power dissipation of a temperature compensated FBAR oscillator presents a promising alternative for replacement of quartz crystal frequency references. The measured frequency post-compensation drift over a 0-100degC temperature range is <20 ppm. The measured phase noise is -125 dBc/Hz at 100 kHz offset from carrier. The overall system power consumption is 960 muW.