Luiz Carlos Soares Figueiredo-Filho

Luiz Carlos Soares Figueiredo-Filho

Auto-generated profile, based on publicly available information

Luiz Carlos Soares Figueiredo-Filho

Departamento de Química, Universidade Federal de São Carlos, P.O. Box 676, 13560-970, São Carlos, SP, Brazil

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Electrochimica Acta
Verified
Journal Article
Closed access
FVFernando C. Vicentini
Fernando C. Vicentini
ARAmanda E. Ravanini
Amanda E. Ravanini
LFLuiz C.S. Figueiredo-Filho
Luiz C.S. Figueiredo-Filho
JIJesús Iniesta
Jesús Iniesta
Craig BanksCraig Banks
Craig Banks
OFOrlando Fatibello-Filho
Orlando Fatibello-Filho

1 September 2011 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
Bruno Campos JanegitzBruno Campos Janegitz
Bruno Campos Janegitz
LFLuiz Carlos S. Figueiredo-Filho
Luiz Carlos S. Figueiredo-Filho
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior
SSSilvéria P.N. Souza
Silvéria P.N. Souza
EPEdenir Pereira-Filho
Edenir Pereira-Filho
OFOrlando Fatibello-Filho
Orlando Fatibello-Filho

5 April 2013 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
Dale BrownsonDale Brownson
Dale Brownson
LFLuiz C. S. Figueiredo-Filho
Luiz C. S. Figueiredo-Filho
XJXiaobo Ji
Xiaobo Ji
MGMaria Gómez-Mingot
Maria Gómez-Mingot
JIJesús Iniesta
Jesús Iniesta
Craig BanksCraig Banks
Craig Banks
Freestanding three-dimensional (3D) graphene foam has been fabricated via a Chemical Vapour Deposition (CVD) methodology which has a macroscopic structure with microscopic (graphene) features. The 3D graphene macrostructure is characterised with SEM, EDX, XPS and Raman spectroscopy and is found to comprise pristine graphene (O/C of 0.05) which is in the range of mono- to few-layered graphene sheets and is thus termed quasi-graphene. This unique 3D graphene foam is electrochemically explored in both aqueous and non-aqueous solutions and compared to a freestanding 3D reticulated vitreous carbon (RVC) foam alternative. In aqueous solutions, the 3D graphene foam exhibits poor voltammetric responses. Contact angle measurements reveal the 3D graphene to exhibit a value of 120° representing quasi-super-hydrophobicity. Consequently the freestanding 3D graphene foam is found to give rise to significantly improved voltammetric signatures in non-aqueous media (ionic liquids) over that of a freestanding 3D RVC alternative. The 3D graphene foam provides a promising and beneficial architecture over 2D pristine graphene due to its ease of use and macroscopic/microscopic structure, which will have wide implementation in the field of electrochemistry.

1 May 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LGLívia Luiza Costa Garcia
Lívia Luiza Costa Garcia
LFLuiz Carlos Soares Figueiredo-Filho
Luiz Carlos Soares Figueiredo-Filho
GOGeiser Gabriel de Oliveira
Geiser Gabriel de Oliveira
OFOrlando Fatibello-Filho
Orlando Fatibello-Filho
Craig BanksCraig Banks
Craig Banks

3 March 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
LFLuiz C. S. Figueiredo-Filho
Luiz C. S. Figueiredo-Filho
Tiago Almeida SilvaTiago Almeida Silva
Tiago Almeida Silva
FVFernando C. Vicentini
Fernando C. Vicentini
OFOrlando Fatibello-Filho
Orlando Fatibello-Filho
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of dopamine (DA) and epinephrine (EP) in human body fluids using a glassy carbon electrode modified with nickel oxide nanoparticles and carbon nanotubes within a dihexadecylphosphate film using square-wave voltammetry (SWV) or differential-pulse voltammetry (DPV). Using DPV with the proposed electrode, a separation of ca. 360 mV between the peak reduction potentials of DA and EP present in binary mixtures was obtained. The analytical curves for the simultaneous determination of dopamine and epinephrine showed an excellent linear response, ranging from 7.0 × 10−8 to 4.8 × 10−6 and 3.0 × 10−7 to 9.5 × 10−6 mol L−1 for DA and EP, respectively. The detection limits for the simultaneous determination of DA and EP were 5.0 × 10−8 mol L−1 and 8.2 × 10−8 mol L−1, respectively. The proposed method was successfully applied in the simultaneous determination of these analytes in human body fluid samples of cerebrospinal fluid, human serum and lung fluid.

21 May 2010 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
LFLuiz Carlos S. de Figueiredo‐Filho
Luiz Carlos S. de Figueiredo‐Filho
VSVagner Bezerra Dos Santos
Vagner Bezerra Dos Santos
Bruno Campos JanegitzBruno Campos Janegitz
Bruno Campos Janegitz
TGThiago Brito Guerreiro
Thiago Brito Guerreiro
OFOrlando Fatibello-Filho
Orlando Fatibello-Filho
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior