Saygun Guler

Saygun Guler

Auto-generated profile, based on publicly available information

Saygun Guler

Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Turkiye

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2022 in IEEE Sensors Letters
Verified
Journal Article
Closed access
SGSaygun Guler
Saygun Guler
Ata GolparvarAta Golparvar
Ata Golparvar
ÖÖÖZBERK ÖZTÜRK
ÖZBERK ÖZTÜRK
Murat Kaya YapiciMurat Kaya Yapici
Murat Kaya Yapici
Ear-centered physiological recordings offer rich amount of information originated by neural and cardiac activities. This paper investigates possible applications of graphene-based textiles for behind-the-ear discreet and unobtrusive electrocardiography (ECG) monitoring. We systematically analyzed the most suitable electrode positioning for wearable ear ECG and identified the mastoid area behind the ear helix to be suitable for cardiac monitoring, where the collected signals had a mean signal-to-noise ratio (SNR) of 29.87 dB. Later, graphene textiles were positioned on the selected locations, and we assessed the feasibility of a wearable headphone design for ear ECG through synchronous recording alongside conventional lead-I placement. We anticipate that contributions here are directly applicable to the extraction of heartrate, heart rate variability (HRV), and other cardiac P-QRS-T parameters for remote health monitoring as well as applications requiring vital signs for real-time stress or anxiety classification such as virtual reality headsets.

29 August 2022 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
SGSaygun Guler
Saygun Guler
ÖÖÖZBERK ÖZTÜRK
ÖZBERK ÖZTÜRK
Ata GolparvarAta Golparvar
Ata Golparvar
HDHuseyin Dogan
Huseyin Dogan
Murat Kaya YapiciMurat Kaya Yapici
Murat Kaya Yapici

11 January 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
SGSaygun Guler
Saygun Guler
AGAta Golparvar
Ata Golparvar
OOOzberk Ozturk
Ozberk Ozturk
HDHuseyin Dogan
Huseyin Dogan
MYMurat Kaya Yapici
Murat Kaya Yapici
Remote photoplethysmography (rPPG) using camera-based imaging has shown excellent potential recently in vital signs monitoring due to its contactless nature. However, the optimum filter selection for pre-processing rPPG data in signal conditioning is still not straightforward. The best algorithm selection improves the signal-to-noise ratio (SNR) and therefore improves the accuracy of the recognition and classification of vital signs. We recorded more than 300 temporal rPPG signals where the noise was not motion-induced. Then, we investigated the best digital filter in pre-processing temporal rPPG data and compared the performances of 10 filters with 10 orders each (i.e., a total of 100 filters). The performances are assessed using a signal quality metric on three levels. The quality of the raw signals was classified under three categories; Q1 being the best and Q3 being the worst. The results are presented in SNR scores, which show that the Chebyshev II orders of 2nd, 4th, and 6th perform the best for denoising rPPG signals.

25 January 2019 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
Luigi ManfrediLuigi Manfredi
Luigi Manfredi
FPFabrizio Putzu
Fabrizio Putzu
SGSaygun Guler
Saygun Guler
YHYu Huan
Yu Huan
ACAlfred Cuschieri
Alfred Cuschieri

22 April 2026 in ACS Nanoscience Au
Verified
Journal Article
Open access
SMSeyed Sajjad Mirbakht
Seyed Sajjad Mirbakht
FBFaruk Ballipinar
Faruk Ballipinar
BKBurcu Arman Kuzubasoglu
Burcu Arman Kuzubasoglu
MTMelih Can Can Tasdelen
Melih Can Can Tasdelen
SGSaygun Guler
Saygun Guler
Murat Kaya YapiciMurat Kaya Yapici
Murat Kaya Yapici

16 January 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SASeba Nur Alhasan
Seba Nur Alhasan
BKBurcu Arman Kuzubasoglu
Burcu Arman Kuzubasoglu
SGSaygun Guler
Saygun Guler
Murat Kaya YapiciMurat Kaya Yapici
Murat Kaya Yapici
Wearable e-textiles have gained significant attention in recent years, particularly for long-term biopotential signal monitoring. In this study, we present two wearable electrode designs—a headband and a neckband—tailored specifically for ECG signal acquisition from behind the ear and around the neck regions. These designs were benchmarked against standard Ag/AgCl electrodes over 30 voluntary participants and demonstrated maximum correlation values as high as 98% and above for both designs, with an average correlation of 90.1% and 91.9% for the headband and neckband, respectively. A detailed investigation of six different electrode placements on the neck was also conducted to determine the optimal positions for recording ECG signals. The robustness of the designs was evaluated through 40-minute ECG recordings and under various intense movement conditions. Furthermore, to advance the development of sustainable and reliable wearable e-textile systems, we evaluated the real-life performance of textile electrodes reduced using two different agents: L-ascorbic acid, an eco-friendly, bio-based compound, and sodium borohydride, a commonly used but toxic chemical. While both agents are already known to effectively reduce graphene oxide, the primary objective was to comparatively assess the functional performance of the resulting electrodes under real-world conditions, specifically in scenarios relevant to wearable ECG monitoring applications. The reported results enhance the understanding of the efficiency and performance of the developed wearable e-textile designs for biopotential signal monitoring.