Bilal Tasdelen

Bilal Tasdelen

Auto-generated profile, based on publicly available information

Bilal Tasdelen

Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering University of Southern California Los Angeles California USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
KKKathryn E. Keenan
Kathryn E. Keenan
BTBilal Tasdelen
Bilal Tasdelen
AJAhsan Javed
Ahsan Javed
RRRajiv Ramasawmy
Rajiv Ramasawmy
RRRudy Rizzo
Rudy Rizzo
Krishna NayakKrishna Nayak
Krishna Nayak

9 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SSShu‐Fu Shih
Shu‐Fu Shih
BTBilal Tasdelen
Bilal Tasdelen
EYEcrin Yagiz
Ecrin Yagiz
ZZZhaohuan Zhang
Zhaohuan Zhang
XZXiaodong Zhong
Xiaodong Zhong
HWHolden Wu
Holden Wu
Purpose: To improve liver proton density fat fraction (PDFF) and quantification at 0.55 T by systematically validating the acquisition parameter choices and investigating the performance of locally low‐rank denoising methods.Methods: A Monte Carlo simulation was conducted to design a protocol for PDFF and mapping at 0.55 T. Using this proposed protocol, we investigated the performance of robust locally low‐rank (RLLR) and random matrix theory (RMT) denoising. In a reference phantom, we assessed quantification accuracy (concordance correlation coefficient [] vs. reference values) and precision (using SD) across scan repetitions. We performed in vivo liver scans (11 subjects) and used regions of interest to compare means and SDs of PDFF and measurements. Kruskal–Wallis and Wilcoxon signed‐rank tests were performed (p < 0.05 considered significant).Results: In the phantom, RLLR and RMT denoising improved accuracy in PDFF and with >0.992 and improved precision with >67% decrease in SD across 50 scan repetitions versus conventional reconstruction (i.e., no denoising). For in vivo liver scans, the mean PDFF and mean were not significantly different between the three methods (conventional reconstruction; RLLR and RMT denoising). Without denoising, the SDs of PDFF and were 8.80% and 14.17 s−1. RLLR denoising significantly reduced the values to 1.79% and 5.31 s−1 (p < 0.001); RMT denoising significantly reduced the values to 2.00% and 4.81 s−1 (p < 0.001).Conclusion: We validated an acquisition protocol for improved PDFF and quantification at 0.55 T. Both RLLR and RMT denoising improved the accuracy and precision of PDFF and measurements.

21 September 2020 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
CACemre Ariyurek
Cemre Ariyurek
BTBilal Tasdelen
Bilal Tasdelen
YIYusuf Ziya Ider
Yusuf Ziya Ider
EAErgin Atalar
Ergin Atalar

12 July 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BTBilal Tasdelen
Bilal Tasdelen
NLNam G. Lee
Nam G. Lee
SCSophia X. Cui
Sophia X. Cui
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: Breath‐held fat‐suppressed volumetric T1‐weighted MRI is an important and widely‐used technique for evaluating the abdomen. Both fat‐saturation and Dixon‐based fat‐suppression methods are used at conventional field strengths; however, both have challenges at lower field strengths (<1.5T) due to insufficient fat suppression and/or inadequate resolution. Specifically, at lower field strengths, fat saturation often fails due to the short T1 of lipid; and Cartesian Dixon imaging provides poor spatial resolution due to the need for a long ∆TE, due to the smaller ∆f between water and lipid. The purpose of this work is to demonstrate a new approach capable of simultaneously achieving excellent fat suppression and high spatial resolution on a 0.55T whole‐body system.Methods: We applied 3D stack‐of‐spirals Dixon imaging at 0.55T, with compensation of concomitant field phase during reconstruction. The spiral readouts make efficient use of the requisite ∆TE. We compared this with 3D Cartesian Dixon imaging. Experiments were performed in 2 healthy and 10 elevated liver fat volunteers.Results: Stack‐of‐spirals Dixon imaging at 0.55T makes excellent use of the required ∆TE, provided high SNR efficiency and finer spatial resolution (1.7 × 1.7 × 5 mm3) compared Cartesian Dixon (3.5 × 3.5 × 5 mm3), within a 17‐s breath‐hold. We observed successful fat suppression, and improved definition of structures such as the liver, kidneys, and bowel.Conclusion: We demonstrate that high‐resolution single breath‐hold volumetric abdominal T1‐weighted imaging is feasible at 0.55T using spiral sampling and concomitant field correction. This is an attractive alternative to existing Cartesian‐based methods, as it simultaneously provides high‐resolution and excellent fat‐suppression.

14 April 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BTBilal Tasdelen
Bilal Tasdelen
EYEcrin Yagiz
Ecrin Yagiz
BCBaran R. Cinbis
Baran R. Cinbis
YTYe Tian
Ye Tian
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To enable contactless cardiac gating at 0.55T using pilot tone (PT). Current PT methods are unable to extract weak motions, including cardiac motion, at lower B0 field strengths (<1.5T).Methods: We utilize high‐amplitude pilot tone with interference cancellation, termed HAPTIC. The use of high amplitude PT improves sensitivity to cardiac motion, but introduces noise leakage into the imaging bandwidth. This leakage is removed using External Dynamic InTerference Estimation and Removal (EDITER) interference cancellation. HAPTIC performance at 0.55T is evaluated in healthy volunteers and patients with cardiac arrhythmia, over a 100‐fold range in PT amplitude. Contactless HAPTIC gating performance is compared against conventional electrocardiogram (ECG). Noise enhancement due to HAPTIC is evaluated using noise‐only scans acquired with varying PT amplitude levels.Results: We demonstrate robust extraction of cardiac PT signals at 0.55T, with cardiac gating (ECG vs. HAPTIC) jitter <9 ms, and noise enhancement ˜12%–35%. We demonstrate the ability to track cardiac and respiratory phase during real‐time MRI and demonstrate reliable separation of cardiac and respiratory phases for retrospective binning using HAPTIC. Furthermore, we demonstrate that HAPTIC provides accurate cardiac gating in the challenging case of arrhythmia to showcase initial feasibility.Conclusion: HAPTIC enables contactless cardiac gating at 0.55T, which has not previously been demonstrated with any PT variant. This could simplify clinical workflow and could serve as a solution for mid‐ and low‐field MRI scanners that do not include built‐in physiological monitoring.

26 March 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
BTBilal Tasdelen
Bilal Tasdelen
ASAlireza Sadeghi‐Tarakameh
Alireza Sadeghi‐Tarakameh
UYUgur Yilmaz
Ugur Yilmaz
EAErgin Atalar
Ergin Atalar