Shaoni Jiao

Shaoni Jiao

Auto-generated profile, based on publicly available information

Shaoni Jiao

Taiyuan University of Technology, Taiyuan, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
SJShaoni Jiao
Shaoni Jiao
XLXiaohua Liu
Xiaohua Liu
ZZZhiwei Zeng
Zhiwei Zeng
Skin depth is an important parameter that quantifies depth of inspection of eddy current (EC) nondestructive testing. The formula which states that the skin depth is inversely proportional to the square root of the product of frequency, permeability, and conductivity has been widely used for calculating skin depth for many decades. It has been noticed that the true skin depth is less than that obtained by the formula when the EC is excited by the ac current in a pancake coil. In-depth and convincible explanation of this discrepancy has not been published. This paper studies this problem by finite-element analysis and concludes that the difference is due to two reasons. One is that the EC associated with pancake coil diffuses with increasing depth, whereas there is no diffusion effect of EC associated with uniform plane field which is the assumption of the conventional formula. The other reason is that the ECs induced by wire segments symmetric about the coil axis cancel each other and the cancellation becomes more severe with increasing depth due to the diffusion of EC. This paper also investigates the influence of each of coil parameters on skin depth. Then, a new formula for estimating skin depth is proposed.

14 January 2024 in Nondestructive Testing and Evaluation
Verified
Journal Article
Closed access
YRYoutian Ren
Youtian Ren
ZZZhiwei Zeng
Zhiwei Zeng
SJShaoni Jiao
Shaoni Jiao

18 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JLJunxia Li
Junxia Li
JGJianke Gao
Jianke Gao
SJShaoni Jiao
Shaoni Jiao
ZKZiming Kou
Ziming Kou
WZWei Zhang
Wei Zhang
YKYanfei Kou
Yanfei Kou
Broken steel wires in the core of the conveyor belt significantly reduce its carrying capacity and overall strength, potentially leading to safety hazards. The eddy current testing (ECT) has significant advantages in terms of cost and portability over other non-destructive testing technologies such as ultrasonic testing (UT) and X-Ray. ECT detects changes in the magnetic field, enabling the detection of the broken steel wires. However, the detection of broken wire ropes in conveyor belt has difficulty in obtaining data under actual working conditions, insufficient data diversity, low recognition accuracy, and poor model generalization ability. This paper designs a differential probe and introduces a novel approach, the CutMix-ReliefF-RF method, which addresses these challenges based on the differential signal. By applying CutMix, we enhance the diversity of small sample data and construct varied datasets representing different numbers of broken wires, which significantly improves the model’s recognition ability and generalization performance. The fault features of the broken steel wires in the core of the conveyor belt are extracted, then the ReliefF method is used for dimensionality reduction to obtain an optimal feature subset. Random forest (RF) algorithm is adopted to identify the broken core characteristics from the eddy current detection signal. The accuracy of the finite element model is validated through experimental and simulation signals used to generate training samples. The proposed method can accurately identify broken steel wires in the core of the conveyor belt, achieving a fault diagnosis accuracy of 98.23% under simulation signals and 96.67% under experimental signals, respectively. This provides strong support for the health monitoring of broken steel wires in the core of the conveyor belt.

26 August 2025 in Measurement
Verified
Journal Article
Closed access
SHShuai Huang
Shuai Huang
JLJunxia Li
Junxia Li
LWLei Wu
Lei Wu
YKYanfei Kou
Yanfei Kou
SJShaoni Jiao
Shaoni Jiao
ZKZiming Kou
Ziming Kou

1 January 2026 in IEEE Open Journal of Instrumentation and Measurement
Verified
Journal Article
Open access
YKYamini Devidas Kotriwar
Yamini Devidas Kotriwar
SSSapana S. Shirsat
Sapana S. Shirsat
KKKhan Bahadar Khan
Khan Bahadar Khan
SCSunil Kishore Chakrapani
Sunil Kishore Chakrapani
SJShaoni Jiao
Shaoni Jiao
YDYiming Deng
Yiming Deng

22 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SJShaoni Jiao
Shaoni Jiao
DLDong Li
Dong Li
HZHaowen Zheng
Haowen Zheng
SHShuai Hao
Shuai Hao
JLJunxia Li
Junxia Li
PSPengpeng Shi
Pengpeng Shi
Eddy Current Testing (ECT) is a core non-destructive testing technique for conductive materials. The traditional single-coil eddy current testing method largely relies on a stable lift-off value, but in practical testing, lift-off perturbations caused by vibrations of the testing equipment directly affects the quality of the eddy current signal, thereby reducing the accuracy of defect evaluation. In this paper, a quantitative evaluation method for aluminum plate defect size based on a normal coaxial dual-receiving coil ECT probe is proposed. First, an ECT experimental system integrating signal excitation, data acquisition and motion control modules is established, and a self-designed normal coaxial dual-receiving coil ECT probe is adopted to realize the joint acquisition of eddy current signals under different lift-off values. A signal symmetrization preprocessing procedure based on flip interpolation and fourth-order low-pass filtering is also established to eliminate the asymmetric perturbation caused by mechanical vibration and platform fluctuation. Second, a three-dimensional finite element simulation model of eddy current based on the normal coaxial dual-receiving coil probe is established, and the distribution laws of the magnetic field and eddy current field are analyzed to verify the reliability of the probe structure design. Finally, ECT experiments and defect size evaluation studies are conducted on aluminum plates with surface circular hole defects, and a fast calculation model for eddy current signals is established based on the testing data of these defects. A quantitative evaluation method for aluminum plate surface defect size that takes lift-off perturbation into account is further constructed based on the particle swarm optimization (PSO) algorithm. This research finds that the peak-to-peak voltage feature of surface circular hole defect signals shows a monotonic correlation with both defect parameters and lift-off values under a lift-off perturbation range of -0.2 mm to 0.2 mm. In the presence of lift-off perturbation, the traditional single-coil ECT method results in an evaluation error of more than 38%, while the proposed ECT system can quantitatively evaluate the radius and depth of circular hole defects with errors controlled within ±0.5% and 4%, respectively. This work provides reliable technical support for the quantitative testing of surface defects in conductive materials under complex industrial conditions.