Xueyan Bai

Xueyan Bai

Auto-generated profile, based on publicly available information

Xueyan Bai

School of Electrical Engineering, Xinjiang University, Urumqi 830046, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2023 in Energy
Verified
Journal Article
Closed access
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
JLJunyi Liu
Junyi Liu

20 June 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
RHRuixin Hao
Ruixin Hao
JYJiaquan Yu
Jiaquan Yu

5 May 2025 in Energy
Verified
Journal Article
Closed access
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou

25 September 2023 in Processes
Verified
Journal Article
Open access
PDF file
JLJunyi Liu
Junyi Liu
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
XBXueyan Bai
Xueyan Bai
The DC collection system of wind farms can effectively solve the problems of harmonic resonance and reactive power transmission in large-scale wind power AC collection systems, and has broad development prospects. The DC/DC converter is critical equipment in the wind farm DC collection system, and its reliability is related to the entire collection system’s safe and stable operation. The reliability of DC/DC converters is affected by factors such as system operating conditions and control strategies. Based on this, a reliability evaluation model for boost full-bridge isolated (BFBIC) DC/DC converters is proposed from the device level to the submodule level and then to the equipment level, incorporating operating conditions and control strategies into reliability analysis. Firstly, in device-level reliability modeling, the impact of DC/DC converter operating conditions and control strategies on insulated gate bipolar transistor (IGBT) module losses and junction temperature fluctuations are considered. Secondly, fault tree analysis (FTA) is used to establish the reliability model of the BFBIC submodule and DC/DC converter. In the end, we verify the effectiveness of the proposed model through a numerical example, and provide solid data support for analyzing the reliability of the wind farm DC collection system.

21 September 2023 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
YLYujia Liu
Yujia Liu

25 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
Wind power DC collection system, as a crucial component of wind farms, plays a vital role in ensuring the safe and stable operation of the entire wind farm. This paper proposes a reliability assessment method for wind power DC collection systems based on MLFTA-SMC. Firstly, it analyzes the topology and key equipment of wind power DC collection systems. Secondly, based on the topology of different wind power DC collection systems, it constructs multi-level fault tree models to calculate the comprehensive importance of different events, thus providing data support for subsequent reliability assessment. Then, it utilizes the MLFTA-SMC method to assess and analyze the reliability of different wind power DC collection system topologies. Finally, taking a 100 MW wind farm in Northwest China as an example, the proposed reliability assessment method is verified through simulation. The results indicate that this method exhibits good effectiveness and superiority.