17 July 2017 in Journal of Applied Physics
This paper presents the characteristics of underwater electrical wire explosion (UEWE) with three discharge types, namely, Type-A, Type-B, and Type-C. Experiments were carried out with copper and tungsten wires (4 cm long and 50–300 μm in diameter) driven by a microsecond time-scale pulsed current source with 500 J stored energy. A time-integrated spectrometer and a photodiode were used to measure the optical emission of UEWE. A Polyvinylidene Fluoride probe was adopted to record the pressure waveforms. Experimental results indicate that from Type-A to Type-C, more energy deposits prior to the voltage peak and the first peak power increases drastically. This variation of energy deposition influences the optical emission and shock wave generation process. Specifically, the light intensity decreases by more than 90% and the peak of continuous spectra moves from ∼400 nm to ∼700 nm. In addition, the peak pressure of the first shock wave increases from ∼2 MPa to more than 7.5 MPa.
8 May 2020 in IEEE Transactions on Instrumentation and Measurement
Avalanche transistor-based Marx bank circuit (MBC) is widely used to generate nanosecond pulses with high amplitude, high repetition rate, fast rise time and low jitter. Recently, the problem that avalanche transistors in the first several stages of M×N-stage MBC fail frequently has been alleviated by adopting auxiliary triggering topology (ATT). However, the reasons for improvement and the optimal design method have not been fully understood. In this paper, a flexible 4×10-stage MBC is developed to further investigate the output characteristics under different modified stages, capacitors and loads through both experiments and simulations. The results show that on the one hand, adopting ATT will cause energy loss of main capacitors to auxiliary triggering capacitors, which can decrease the output voltage; on the other hand, transistors operating in auxiliary triggering switching-on mode have lower residual voltage than in overvoltage switching-on mode, which can increase the output voltage. This implies that there exists an optimal value of modified stages, which is 5 for the 4×10-stage MBC. Besides, by adopting ATT, the waveform of output pulse changes, and the rising edge becomes faster. Finally, a repetitive nanosecond pulse generator is developed based on the optimized parameters, which can produce pulses with amplitude of 9.04 kV, rise time of 3.4 ns, pulse width of 18.8 ns and maximum repetition rate of 1 kHz at the 75Ω openended cable. And the feasibility of this modified MBC is validated by the preliminary experiments of driving atmospheric pressure plasma jet (APPJ).
26 April 2021 in IEEE Transactions on Instrumentation and Measurement
Avalanche transistor (AT)-based repetitive nanosecond pulse generators with high amplitude, fast rise time, narrow pulse width, and low jitter have been widely developed and applied in numerous fields. However, relatively little research has been carried out on the positive nanosecond pulse generation with high flexibility in a wide range of output voltage amplitude. In this article, a novel AT-based Marx circuit (MC) topology adopting base-triggering method is proposed to avoid the formation of current filamentation inside the transistors and resolve the contradiction between high-voltage output and high repetition rate operation. A 6×10-stage MC prototype is implemented with optimized parameters to validate the feasibility of the proposed topology. The conduction processes of transistors show that, with the injection of additional base current, the switched-ON modes are transformed, which contributes to reliable conduction of transistors even without sufficient overvoltage ramp. With the adoption of inner triggering loops, the minimum working voltage of the prototype is extended to 1150 V. The operation characteristics of the generator in the whole operation range are investigated in depth. Experimental results illustrate that, at the 75- Ω match-ended coaxial cable, the prototype is capable of generating positive pulses with an adjustable voltage amplitude in the range of 6.50 to 12.39 kV, a basically consistent rise time of 3.6 ns and pulse width of 19.5 ns. Over 10 7 successive pulses are generated at a maximum repetition rate of 1 kHz without any device failure.
18 August 2017 in IEEE Transactions on Plasma Science
The capillary-based pulsed plasma thruster (PPT) has high-energy transfer efficiency, which provides potential to improve traditional PPT performance. In this paper, the discharge characteristics of a capillary-based PPT have been investigated. First, the typical process of voltage and current waveform is recognized. It is featured with a fast voltage drop (~25 ns) and a consequent damped sine wave oscillation discharge. Then based on the circuit analysis, the equivalent plasma resistance has been calculated. The current waveform is well fit with a linearly increasing resistance model. The influence of charging voltage has also been studied. The deposited energy increases while the transfer efficiency decreases with the increasing applied voltage. The cavity dimension has effects on the equivalent circuit parameters. The results show that longer cavity and smaller diameter lead to more deposited energy and higher transfer efficiency. The influence of voltage and capillary dimension on the mass shot characteristic has been discussed. Finally, the estimated impulse bit has been calculated and the impulse bit characteristics have been discussed. These results can contribute to the further optimization of PPT.
1 October 2017 in Review of Scientific Instruments
A platform SWE-2 used for single wire explosion experiments has been designed, established, and commissioned. This paper describes the design and initial experiments of SWE-2. In summary, two pulsed current sources based on pulse capacitors and spark gaps are adopted to drive sub-microsecond and microsecond time scale wire explosions in a gaseous/liquid medium, respectively. In the initial experiments, a single copper wire was exploded in air, helium, and argon with a 0.1-0.3 MPa ambient pressure as well as tap water with a 283-323 K temperature, 184-11 000 S/cm conductivity, or 0.1-0.9 MPa hydrostatic pressure. In addition, the diagnostic system is introduced in detail. Energy deposition, optical emission, and shock wave characteristics are briefly discussed based on experimental results. The platform was demonstrated to operate successfully with a single wire load. These results provide the potential for further applications of this platform, such as plasma-matter interactions, shock wave effects, and reservoir simulations.
17 June 2019 in IEEE Transactions on Plasma Science
High power pseudospark switches (PSSs) can control pulsed high voltage, high peak current discharges. In this paper, a PSS in series with a saturable inductor at the anode is investigated. The commutation process is analyzed with a time-resolved method. And the effects of the number of magnetic cores and anode voltages on discharge characteristics are studied experimentally. At the beginning of commutation process, when the anode voltage is 10.4 kV with four magnetic cores, the inductor is unsaturated, and there is a flat plateau of the forward voltage drop after the anode voltage drops rapidly to about 200 V, at the same time the current rise rate is 2.8 kA/μs. When the inductor is saturated, there is a voltage spike that occurs at the end of the flat plateau, and the current simultaneously rises rapidly at the rate of 6.4 kA/μs. The current sharp rise lags behind the voltage drop of the pseudospark gap, and the electrode erosion and energy dissipation reduce significantly. When the anode voltage is 15.6 kV, the commutation losses reduce by about 30% with seven cores in series at the anode. As a result, it is evident that the discharge process will speed up if the anode voltage is higher. And the trigger delay decreases by up to 8% when the anode voltage varies from 5.2 to 15.6 kV. Finally, in order to obtain a reproducible pseudospark discharge by the use of a saturable inductor, the number of magnetic cores has to be optimized for different anode voltages.