Shahriar Hossain

Shahriar Hossain

Auto-generated profile, based on publicly available information

Shahriar Hossain

Department of Electronics and Telecommunication Engineering, Rajshahi University of Engineering and Technology, Rajshahi, Bangladesh

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2024 in IEEE Access
Verified
Journal Article
Open access
SHShahriar Hossain
Shahriar Hossain
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
Sudipto MondalSudipto Mondal
Sudipto Mondal
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Afef FekihAfef Fekih
Afef Fekih
Research into solar PV fed grid-tied multilevel inverters (MLIs) has increased in recent years due to their distinct features compared to two-level voltage source inverters (VSIs). However, maintaining the power quality of MLIs is a challenging problem that encompasses the reduction of total harmonic distortion (THD), dc-link voltage imbalance issues, power loss reduction and thermal stress mitigation; which are significantly affected by the applied pulse width modulation (PWM) technique. In order to tackle the above mentioned power quality problems, this work presents a modified hybrid PWM technique which combines a modified modulating signal with a modified carrier signal. The comparison between the proposed and the existing PWM techniques is performed under different conditions and using a wide range of modulation index variations. A grid-tied three-phase three-level T-type neutral point clamped (NPC) inverter is adopted for the power quality assessment. The proposed hybrid PWM offers 25.57% output line voltage THD and 11.8 V peak-to-peak dc-link capacitor voltage difference which are lower than existing PWM techniques. Additionally, by reducing the switching and conduction losses of the power switches, the proposed hybrid PWM technique offers lower thermal stress than existing PWM techniques. The comparison analysis between the existing and the proposed hybrid PWM technique is carried out using MATLAB/Simulink and PLECS simulation environments. The proposed hybrid PWM technique is further validated using a reduced scale prototype developed in our research laboratory.

28 June 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
RFRizwan Amir Fahim
Rizwan Amir Fahim
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
MHMd Kamal Hosain
Md Kamal Hosain
SHShahriar Hossain
Shahriar Hossain
Sudipto MondalSudipto Mondal
Sudipto Mondal
Afef FekihAfef Fekih
Afef Fekih
Total harmonic distortion (THD) and power loss have a substantial effect on the power quality of multilevel inverter (MLIs). They are both directly impacted by the switching method of pulse width modulation (PWM). Nevertheless, traditional PWM methods designed for MLIs have challenges that result in higher THD and problems with power loss. A modified level-shifted carrier-based switching technique is presented in this work. The main goal of the proposed PWM technique is to reduce power losses and THD of neutral-point-clamped (NPC) inverters. The software platforms PLECS and MATLAB/Simulink are used thoroughly to model and simulate the whole system. Moreover, an experimental test at a reduced scale is conducted to verify the results of the simulation study, validating the feasibility of the suggested PWM technique.

18 September 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SHShahriar Hossain
Shahriar Hossain
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
Sudipto MondalSudipto Mondal
Sudipto Mondal
JNJoysree Nath
Joysree Nath
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
Multilevel inverters (MLIs) have significantly improved the overall performance, dependability and efficiency of the renewable energy system. Moreover, these can be easily integrated with the superconducting magnetic energy storage (SMES) systems. Maintaining the power qualities of these MLIs is always marked as a major research concern which can be heavily impacted by the pulse width modulation (PWM) strategies. An improved voltage balancing discontinuous PWM (DPWM) scheme is suggested in this work for the single-phase grid-tied 5-level neutral point clamped (NPC) inverter, which can significantly mitigate the fluctuation of the dc-link capacitor voltages as well as the switching losses of the power IGBTs. The reduction in switching losses will give lower thermal stress to the power devices. The proposed DPWM scheme is compared with other existing DPWM schemes for proving its effectiveness. The simulation of the entire system is performed by using MATLAB Simulink and PLECS simulation platform. A lower scale prototype is also constructed in the laboratory.

1 May 2026 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Sudipto MondalSudipto Mondal
Sudipto Mondal
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
MHMd Kamal Hosain
Md Kamal Hosain
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
KMKashem M. Muttaqi
Kashem M. Muttaqi
SSSharmin Shila
Sharmin Shila
In this paper, a modified Carrier Amplitude Shifted Pulse Width Modulation (CAS-PWM) technique is introduced that utilizes a new level-shifted carrier waveform and a modified modulation signal for three-level Neutral Point Clamped (NPC) inverter systems. The proposed CAS-PWM strategy is aimed at reducing output voltage total harmonic distortion (THD), inverter power losses, and thermal distribution on switching devices. Unlike traditional PWM methods, Phase Disposition (PD), Phase Opposition Disposition (POD), Alternate Phase Opposition Disposition (APOD), Interleaved Carrier (IC), Phase-Shifted Carrier (PSC) and other advanced carrier based control, the CASPWM modifies the carrier amplitude and modulation waveform at the same time to provide the suitable switching states. A comprehensive benchmarking is made with nine carrier methods and five existing modulation techniques such as SPWM, CSVPWM, THPWM, and SDPWM. The principle of the proposed CAS-PWM is to enhance the quality of the output voltage, to decrease the switching and conduction loss of power switches, and to improve the neutral-point capacitor voltage balancing as much as possible. The proposed scheme and overall system is verified through MATLAB/Simulink simulations and a 1-kW laboratory scaled prototype, demonstrating its suitability for photovoltaic (PV) grid integration. Overall, an extensive thermal analysis is conducted in PLECS computer simulation environment and real time hardware with a thermal imaging camera that indicates a significant decrease in IGBT junction temperature.

7 April 2026 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
SHShahriar Hossain
Shahriar Hossain
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
Sudipto MondalSudipto Mondal
Sudipto Mondal
MHMd. Hossain
Md. Hossain
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
The use of neutral point clamped (NPC) multilevel inverters has significantly increased in recent decades, due to their appealing features compared to two-level voltage source inverters. In many industry-level applications, they suffer from high harmonic distortion, power loss, junction temperature of the semiconductor switches and dc-link capacitor voltage imbalance issues which are largely dependent on the switching pulse width modulation (PWM) technique used. This work presents a sub-flattened triangular carrier-based pulse width modulation (PWM) technique, which can mitigate the aforementioned issues. The proposed PWM technique is a combination of the modulating signal of existing third-harmonic injected PWM (THPWM) and a newly shaped, sub-flattened, modified triangular carrier signal. The carrier signal introduces a flattened region, which modifies the switching sequences of the power switches. This modification significantly affects the harmonic profile, charging and discharging time of the dc-link capacitors, the total power loss, switch junction temperature and efficiency of the inverter. A three-phase grid-connected T-type NPC inverter is considered to evaluate the performance of the proposed PWM technique. An extensive comparative performance analysis of the proposed PWM technique has been carried out against existing PWM methods. The evaluation considers key performance indicators, including inverter PWM voltage harmonic profile, dc-link capacitor voltage balancing, power losses, junction temperature of the switches, and overall inverter efficiency. Simulations have been conducted using MATLAB/Simulink and PLECS platforms. Furthermore, a reduced-scale laboratory prototype has been developed and experimentally validated to support the simulation results.