8 June 2020 in Physiological Reports
Blood glucose can be controlled by electrically stimulating the vagus nerve. This approach could be a promising therapy of type 2 diabetes.
19 April 2022 in Physiological Reports
Vagus nerve stimulation is emerging as a promising treatment for type 2 diabetes. Here, we evaluated the ability of stimulation of the vagus nerve to reduce glycemia in awake, freely moving metabolically compromised rats. A model of type 2 diabetes (n = 10) was induced using a high‐fat diet and low doses of streptozotocin. Stimulation of the abdominal vagus nerve was achieved by pairing 15 Hz pulses on a distal pair of electrodes with high‐frequency blocking stimulation (26 kHz, 4 mA) on a proximal pair of electrodes to preferentially produce efferent conducting activity (eVNS). Stimulation was well tolerated in awake, freely moving rats. During 1 h of eVNS, glycemia decreased in 90% of subjects (−1.25 ± 1.25 mM h, p = 0.017), and 2 dB above neural threshold was established as the most effective “dose” of eVNS (p = 0.009). Following 5 weeks of implantation, eVNS was still effective, resulting in significantly decreased glycemia (−1.7 ± 0.6 mM h, p = 0.003) during 1 h of eVNS. There were no overt changes in fascicle area or signs of histopathological damage observed in implanted vagal nerve tissue following chronic implantation and stimulation. Demonstration of the biocompatibility and safety of eVNS in awake, metabolically compromised animals is a critical first step to establishing this therapy for clinical use. With further development, eVNS could be a promising novel therapy for treating type 2 diabetes.
31 January 2025 in Clinical & Experimental Ophthalmology
BCBionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium
Bionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium
+9
Background: To assess the safety and stability profile of the suprachoroidal retinal prosthesis (ScRP) in participants with retinitis pigmentosa (RP) for 2 years from implantation. Methods: Four participants, with advanced RP and bare‐light perception vision were enrolled in a prospective, single arm unmasked interventional clinical trial and unilaterally implanted with a 44‐channel ScRP (NCT03406416). Electrical stimulation commenced in the psychophysics laboratory prior to use in local environments. Outcome measures included serious adverse events, adverse events, implant stability and implant functionality to assess the safety and stability profile over 2.0–2.7 years. Results: Surgical procedures took 204–260 min and were uncomplicated. Postoperative recovery was uneventful. Imaging confirmed the device position under the macula and the absence of retinal trauma. There were no serious adverse events and the adverse events that occurred were mild. All electrodes were functional at surgery completion, and only 3% electrodes lost functionality by study end. There was minor array movement (translational and rotational) within the first 10–15 weeks only. The electrode to retina distance increased as expected with fibrous capsule development, but plateaued in three of four participants within 12 months. Retinal and choroidal thicknesses were consistent with the underlying retinal dystrophic disease. Conclusions: The ScRP can be safely implanted in the suprachoroidal space and has minimal long‐term impacts on the eye, with no SAEs and only slight array movement seen over 2.0–2.7 years. Hence, the findings indicate approach feasibility and further multicentre studies are warranted.
1 August 2020 in Journal of Neural Engineering
Objective. Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. Approach. A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. Main results. The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. Significance. The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.
19 March 2020 in Journal of Neural Engineering
Objective. The efficacy of deep brain stimulation can be limited by factors including poor selectivity of stimulation, targeting error, and complications related to implant reliability and stability. We aimed to improve surgical outcomes by evaluating electrode leads with smaller diameter electrode and microelectrodes incorporated which can be used for assisting targeting. Approach . Electrode arrays were constructed with two different diameters of 0.65 mm and the standard 1.3 mm. Micro-electrodes were incorporated into the slim electrode arrays for recording spiking neural activity. Arrays were bilaterally implanted into the medial geniculate body (MGB) in nine anaesthetised cats for 24–40 h using stereotactic techniques. Recordings of auditory evoked field potentials and multi-unit activity were obtained at 1 mm intervals along the electrode insertion track. Insertion trauma was evaluated histologically. Main results . Evoked auditory field potentials were recorded from ring and micro-electrodes in the vicinity of the medial geniculate body. Spiking activity was recorded from 81% of the microelectrodes approaching the MGB. Histological examination showed localized surgical trauma along the implant. The extent of haemorrhage surrounding the track was measured and found to be significantly reduced with the slim electrodes (541 ± 455 µ m vs. 827 ± 647 µ m; P < 0.001). Scoring of the trauma, focusing on tissue disruption, haemorrhage, oedema of glial parenchyma and pyknosis, revealed a significantly lower trauma score for the slim electrodes ( P < 0.0001). Significance . The slim electrodes reduced the extent of acute trauma, while still providing adequate electrode impedance for both stimulating and recording, and providing the option to target stimulate smaller volumes of tissue. The incorporation of microelectrodes into the electrode array may allow for a simplified, single-step surgical approach where confirmatory micro-targeting is done with the same lead used for permanent implantation.
30 May 2025 in Journal of Neural Engineering
Objective. Implantable neural interfaces enable recording of high-quality brain signals that can improve our understanding of brain function. This work examined the feasibility of using a minimally invasive endovascular neural interface (ENI) to record interpretable cortical activity from the visual cortex. Approach. A sheep model (n = 5) was used to record and decode visually evoked potentials from the cortex both with an ENI and a subdural electrode grid. Sets of distinct experimental visual stimuli were presented to attempt decoding from the recorded cortical potentials, using perceptual categories of colour, contrast, movement direction orientation, spatial frequency and temporal frequency. Decoding performances are presented as accuracy scores from K-fold cross-validation of a stratified random forest classification model. The study compared the signal quality and decoding performance between the ENI and electrocorticography (ECoG) electrodes. Main results. Recordings from the ENI array resulted in lower decoding performances than the ECoG array, but the classification scores were significantly above chance in the stimuli categories of colour, contrast, direction and temporal frequency. This study is the first report of visually evoked neural activity using a minimally-invasive ENI. Significance. Overall, the results show that implantable macro-electrodes yield sufficient neural signal definition to discern primary visual percepts, using both endo-vascular and intracranial surgical placements.