Seyed Masood Mostafavi

Seyed Masood Mostafavi

Auto-generated profile, based on publicly available information

Seyed Masood Mostafavi

Electrical Engineering Department, Sharif University of Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MAMohammadreza Amjadian
Mohammadreza Amjadian
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
JCJiangbo Chen
Jiangbo Chen
ZKZahra Kavehvash
Zahra Kavehvash
JZJingyi Zhu
Jingyi Zhu
LWLidai Wang
Lidai Wang
A novel super-resolution volumetric photoacoustic microscopy, based on the theory of structured-illumination, is proposed in this paper. The structured-illumination will be introduced in order to surpass the diffraction limit in a photoacoustic microscopy (PAM) structure. Through optical excitation of the targeted object with a sinusoidal spatial fringe pattern, the object’s frequency spectrum is forced to shift in the spatial frequency domain. The shifting in the desired direction leads to the passage of the high-frequency contents of the object through the passband of the acoustic diffraction frequency response. Finally, combining the low-frequency image with the high-frequency parts in four regular orientations in the spatial frequency domain is equivalent to imaging the targeted object with an imaging system of two-fold bandwidth and thus half lateral resolution. In order to obtain the image of out-of-focus regions and improve the lateral resolution outside the focal region of a PAM imaging system, Fourier-domain reconstruction algorithm based on the synthetic aperture focusing technique (SAFT) using the virtual detector concept is utilized for reduction in the required computational load and time. The performance of the proposed imaging system is validated with in vivo and ex vivo targets. The experimental results obtained from several tungsten filaments in the depth range of 1.2 mm, show an improvement of −6 dB lateral resolution from 55– $287~\boldsymbol \mu \text{m}$ to 25– $29~\boldsymbol \mu \text{m}$ and also an improvement of signal-to-noise ratio (SNR) from 16–22 dB to 27–33 dB in the proposed system.

21 May 2022 in Photoacoustics
Verified
Journal Article
Open access
SHSoheil Hakakzadeh
Soheil Hakakzadeh
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
ZKZahra Kavehvash
Zahra Kavehvash
Praveenbalaji RajendranPraveenbalaji Rajendran
Praveenbalaji Rajendran
MPManojit Pramanik
Manojit Pramanik
In photoacoustic tomography (PAT) systems, the tangential resolution decreases due to the finite size of the transducer as the off-center distance increases. To address this problem, we propose a multi-angle detection approach in which the transducer used for data acquisition rotates around its center (with specific angles) as well as around the scanning center. The angles are calculated based on the central frequency and diameter of the transducer and the radius of the region-of-interest (ROI). Simulations with point-like absorbers (for point-spread-function evaluation) and a vasculature phantom (for quality assessment), and experiments with ten 0.5 mm-diameter pencil leads and a leaf skeleton phantom are used for evaluation of the proposed approach. The results show that a location-independent tangential resolution is achieved with 150 spatial sampling and central rotations with angles of ±8°/±16°. With further developments, the proposed detection strategy can replace the conventional detection (rotating a transducer around ROI) in PAT.

5 January 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
SHSoheil Hakakzadeh
Soheil Hakakzadeh
MAMohammadreza Amjadian
Mohammadreza Amjadian
YZYachao Zhang
Yachao Zhang
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
ZKZahra Kavehvash
Zahra Kavehvash
LWLidai Wang
Lidai Wang
In a photoacoustic (PA) imaging system, the detectors are bandwidth-limited. Therefore, they capture PA signals with some unwanted ripples. This limitation degrades the resolution/contrast and induces sidelobes and artifacts in the reconstructed images along the axial direction. To compensate for the limited bandwidth effect, we present a PA signal restoration algorithm, where a mask is designed to extract the signals at the absorber positions and remove the unwanted ripples. This restoration improves the axial resolution and contrast in the reconstructed image. The restored PA signals can be considered as the input of the conventional reconstruction algorithms (e.g., Delay-and-sum (DAS) and Delay-multiply-and-sum (DMAS)). To compare the performance of the proposed method, DAS and DMAS reconstruction algorithms were performed with both the initial and restored PA signals on numerical and experimental studies (numerical targets, tungsten wires, and human forearm). The results show that, compared with the initial PA signals, the restored PA signals can improve the axial resolution and contrast by 45% and 16.1 dB, respectively, and suppress background artifacts by 80%.

21 June 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MAMohammadreza Amjadian
Mohammadreza Amjadian
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
JCJiangbo Chen
Jiangbo Chen
LWLidai Wang
Lidai Wang
Zhengtang LuoZhengtang Luo
Zhengtang Luo
Acoustic-resolution photoacoustic microscopy (AR-PAM) system can provide 3-D images of facial tissues. The lateral resolution of AR-PAM depends on the numerical aperture (NA) of the acoustic lens and the central frequency of the ultrasonic transducer. There is a trade-off between resolution enhancement and imaging depth. The acoustic beam is tight in the acoustic focal plane but expands in the out-of-focus regions, deteriorating the resolution. High-NA AR-PAM has depth-variant resolution. Synthetic aperture focusing technique (SAFT) based on a virtual detector (VD) concept can compensate for the beam shape and improve the lateral resolution via beamforming. Although, beamforming can enhance the resolution but the lateral resolution in the focal plane is still limited by acoustic diffraction. Structured-illumination can shift the spatial spectrum of an image to low frequencies hence high-frequency contents can be reserved to overcome the diffraction limit. Conventional structured-illumination via using a three-phase-shifting method can improve the resolution by two folds. Here, a modified phase-shifting method is used to generate the second harmonic of the fringes and double the spectral shift. In this idea, higher frequency information compared to the three-phase shifting method can fall into the band-limited system response. The modified phase-shifting method expands the spatial bandwidth and increases the lateral resolution by five folds. The mathematical relations and the theory are discussed in the context. Tungsten filament result shows resolution improvement from 44.6 μm to 11.3 μm by the modified structured illumination. In vivo and ex vivo experimental results validate the system performance.

2 July 2024 in Optics Express
Verified
Journal Article
Closed access
MAMohammadreza Amjadian
Mohammadreza Amjadian
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
JCJiangbo Chen
Jiangbo Chen
JZJingyi Zhu
Jingyi Zhu
JMJun Ma
Jun Ma
LWLidai Wang
Lidai Wang
Filter-based vessel enhancement algorithms facilitate the extraction of vascular networks from medical images. Traditional filter-based algorithms struggle with high noise levels in images with false vessel extraction, and a low standard deviation (σ) value may introduce gaps at the centers of wide vessels. In this paper, a robust technique with less sensitivity to parameter tuning and better noise suppression than other filter-based methods for two-dimensional and three-dimensional images is implemented. In this study, we propose a filter that employs non-local means (NLM) for denoising, applying the vesselness function to suppress blob-like structures and filling the gaps in wide vessels without compromising edge quality or details. Acoustic resolution photoacoustic microscopy (AR-PAM) systems generate high-resolution volumetric photoacoustic images, but their vascular structure imaging suffers from out-of-focal signal-to-noise ratio (SNR) and lateral resolution loss. Implementing a synthetic aperture focusing technique (SAFT) based on a virtual detector (VD) improves out-of-focal region resolution and SNR. Combining the proposed filter with the SAFT algorithm enhances vascular structural imaging in AR-PAM systems. The proposed method is robust and applicable for animal tissues with less error of vasculature structure extraction in comparison to traditional fliter-based methods like Frangi and Sato filter. Also, the method is faster in terms of processing speed and less tuning parameters. We applied the method to a digital phantom to validate our approach and conducted in vivo experiments to demonstrate its superiority for real volumetric tissue imaging.

5 September 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VNVahid Amin Nili
Vahid Amin Nili
ZKZahra Kavehvash
Zahra Kavehvash
SMSeyed Masood Mostafavi
Seyed Masood Mostafavi
MSMahdi Shabany
Mahdi Shabany
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
In pulse-echo ultrasound (US) imaging, achieving higher lateral resolution requires increasing the transmit frequency, which results in penetration depth reduction. Given this trade-off between penetration depth and spatial resolution, we propose a method to resolve sub-diffraction scale structures in synthetic aperture (SA) US imaging. While structured illumination (SI) has previously been employed in US imaging, we introduce its application in SA US imaging to achieve superior resolution. In our approach, grating patterns are superimposed on the object to exploit high-frequency information, enhancing spatial resolution beyond conventional diffraction limits. However, a key challenge arises in applying SI to SA imaging: structured patterns cannot be directly generated using the single-element or multi-element transmissions inherent to SA. To overcome this, we introduce a novel method where pseudo-random plane wave (PW) illuminations are applied, followed by the retrieval of SA data from the acquired dataset. Five SA images corresponding to different SI pattern shifts are reconstructed and post-processed to generate a high-resolution structured illumination synthetic aperture (SISA) image. In-silico point spread function results reveal a 122% and 47% enhancement in lateral resolution when compared to conventional PW imaging (one-way focusing) and SA imaging (two-way focusing) for a grating pattern with a spatial frequency of 0.91 mm⁻¹. Furthermore, two additional in-silico studies were conducted to evaluate contrast and resolution under realistic conditions, demonstrating the superior performance of our proposed method compared to the previously reported acoustic SI technique. Additionally, two experiments validated the contrast and resolution performance of the proposed method in in-vitro conditions. The method possesses a wide range of applications, particularly in the detection of lesions demanding high spatial resolution.