Daniel Remon

Daniel Remon

Auto-generated profile, based on publicly available information

Daniel Remon

Department of Electrical Engineering, Technical University of Catalonia, GAIA Building, Terrassa, Barcelona, Spain 08222

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2017 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
DRDaniel Remon
Daniel Remon
ACAntoni M. Cantarellas
Antoni M. Cantarellas
JMJuan Manuel Mauricio
Juan Manuel Mauricio
PRPedro Rodriguez
Pedro Rodriguez
The utilisation of renewable sources brings many benefits to electric power systems, but also some challenges such as the impact that renewable power plants employing power electronics have on the grid, which is gaining importance as the penetration of this type of generating stations increases, driven by the construction of large wind or solar photovoltaic (PV) power plants. This study analyses the impact of large‐scale PV power plants on a transmission grid for different penetration levels. The analysis considers power plants formed by a number of power converters employing synchronous power controllers (SPCs), that allow them to have a harmonious interaction with the grid, and compares their performance with that of conventional power converter controllers, assuming in both cases that the power plants participate in frequency and voltage regulation. The study addresses both the small‐signal stability of the system and its response to large disturbances that alter the active power balance and frequency stability. The results of the analysis show that PV power plants using SPCs are able to limit frequency deviations, improve the oscillation damping, and reduce the stress of other generating units, thus having a beneficial impact on the power system.

31 January 2017 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
WZWeiyi Zhang
Weiyi Zhang
DRDaniel Remon
Daniel Remon
PRPedro Rodriguez
Pedro Rodriguez
Grid‐interactive converters with primary frequency control and inertia emulation have emerged and are promising for future renewable generation plants because of the contribution in power system stabilisation. This study gives a synchronous active power control solution for grid‐interactive converters, as a way to emulate synchronous generators for inerita characteristics and load sharing. As design considerations, the virtual angle stability and transient response are both analysed, and the detailed implementation structure is also given without entailing any difficulty in practice. The analytical and experimental validation of frequency support characteristics differentiates the work from other publications on generator emulation control. The 10 kW simulation and experimental frequency sweep tests on a regenerative source test bed present good performance of the proposed control in showing inertia and droop characteristics, as well as the controllable transient response.

11 August 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
DRDaniel Remon
Daniel Remon
CCClaudio A. Cañizares
Claudio A. Cañizares
PRPedro Rodriguez
Pedro Rodriguez
The impact that renewable energy sources interfaced by power electronics have on power systems becomes more important as their share in the generation mix increases, thus requiring detailed analyses that take into account their dynamics and controllers. In this study, the impact of photovoltaic (PV) power plants on the power system of northern Chile is analysed. The studied plants employ a controller that allows power converters to interact with the grid like virtual synchronous generators, and their model includes the dynamics of the plant and converter controllers, as well as the dc and PV system. The presented analysis, which comprises modal analysis and time‐domain simulations of large disturbances, evaluates the impact of these plants with respect to PV plants based on a conventional converter controller. Tests and validations of the proposed models and controllers are carried out for an actual PV plant connected to the power system of northern Chile, and for a higher PV penetration case. The results show the ability of PV plants formed by virtually synchronous power converters to limit frequency excursions induced by large power imbalances, and to mitigate power oscillations of the synchronous machines in the system.

1 July 2014
Verified
Conference Paper
Closed access
DRDaniel Remon
Daniel Remon
ACAntoni M. Cantarellas
Antoni M. Cantarellas
Elyas RakhshaniElyas Rakhshani
Elyas Rakhshani
ICIgnacio Candela
Ignacio Candela
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
The increasing penetration of renewable energy sources in power systems requires new control systems that provide services similar to those of conventional generators. This paper proposes an active power controller that is able to automatically achieve synchronization with the grid and to control the DC link voltage. Through this controller, the converter can be identified with a virtual synchronous generator whose kinetic energy is stored in the DC link. Moreover, the active power loop becomes a second order system whose damping can be programmed freely.

1 October 2014
Verified
Conference Paper
Closed access
DRDaniel Remon
Daniel Remon
ACAntoni M. Cantarellas
Antoni M. Cantarellas
Elyas RakhshaniElyas Rakhshani
Elyas Rakhshani
ICIgnacio Candela
Ignacio Candela
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Renewable energy sources are increasing their penetration in power systems, making necessary new control systems that offer services usually provided only by conventional generators. In this paper, an active power controller able to achieve synchronization with the grid and to control the DC link voltage is proposed. This controller allows identifying the converter with a virtual synchronous generator whose inertia can be modified online, considering that its virtual kinetic energy is stored in the DC link. Additionally, the resulting active power loop is a second order system whose damping factor can be defined freely.

7 September 2016 in Energies
Verified
Journal Article
Open access
PDF file
WZWeiyi Zhang
Weiyi Zhang
DRDaniel Remon
Daniel Remon
ACAntoni M. Cantarellas
Antoni M. Cantarellas
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
High level penetration of renewable energy sources has reshaped modern electrical grids. For the future grid, distributed renewable power generation plants can be integrated in a larger scale. Control of grid-connected converters is required to achieve fast power reference tracking and further to present grid-supporting and fault ride-through performance. Among all of the aspects for converter control, the inner current loop for grid-connected converters characterizes the system performance considerably. This paper proposes a unified current loop tuning approach for grid-connected converters that is generally applicable in different cases. A direct discrete-time domain tuning procedure is used, and particularly, the selection of the phase margin and crossover frequency is analyzed, which acts as the main difference compared with the existing studies. As a general method, the approximation in the modeling of the controller and grid filter is avoided. The effectiveness of the tuning approach is validated in both simulation and experimental results with respect to power reference tracking, frequency and voltage supporting.