ChangHyun Noh

ChangHyun Noh

Auto-generated profile, based on publicly available information

ChangHyun Noh

ITER organization, St Paul Lez Durance, FRANCE

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2015 in Fusion Engineering and Design
Verified
Journal Article
Closed access
CNC.H. Noh
C.H. Noh
WCW. Chung
W. Chung
JLJ. Lim
J. Lim
BLB.C. Lee
B.C. Lee

6 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSStefano Sgobba
Stefano Sgobba
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
MCMichal Celuch
Michal Celuch
MCMickaël Crouvizier
Mickaël Crouvizier
AFAna Teresa Perez Fontenla
Ana Teresa Perez Fontenla
CNChangHyun Noh
ChangHyun Noh
The ITER Thermal Shields (TS) consist of actively cooled stainless steel panels. Their role is to minimise the radiation heat load from warm components, such as the Vacuum Vessel (VV) and the cryostat, hence contributing to insulating the magnet system operating at 4.5 K. The panels, cooled by 304L stainless steel pipes stitch welded to 10 mm to 20 mm thick 304LN plates, were coated by a low emissivity silver layer following welding of the pipes and bending operations. Pressurised He gas flows in the pipes at a temperature of 80 K and a pressure of 1.8 MPa at the inlet. These components have been manufactured and delivered to IO and their assembly had been started. Three leaks were detected in Helium leak tests during site acceptance test of the TS. A failure analysis was carried out based on advanced non-destructive and destructive examination techniques, including X-ray microtomography and Focused Ion Beam - Scanning Electron Microscopy (FIB-SEM), confirming crack initiations of different severities, in particular presence of multi-branched “lightning bolt” transgranular cracks through the thickness of the pipes and of corrosion residues featuring high chlorine content. The root cause of the leakages has been univocally associated to Stress Corrosion Cracking (SCC), initiated by halide residues from the silver coating process in combination with the stress induced by the attachment, by welding, of the pipes to the plates. The paper summarises the results of these investigations and the lessons learned, the remedial actions implemented and the planned repair/replacement solutions.

29 July 2016 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
CNC. H. Noh
C. H. Noh
WCW. Chung
W. Chung
JLJ. Lim
J. Lim
BLB. C. Lee
B. C. Lee
The ITER lower cryostat thermal shield (LCTS) is fixed to the cryostat floor by thin flexible plate supports made of titanium alloy. A 500-mm high and 12-mm thick plate support is adopted as a reference design. However, design optimization is requested to save manufacturing costs, because the titanium alloy is expensive to fabricate. In addition to the reduction in mass, a design study was performed by using stainless steel as an alternative material for better manufacturability. This paper describes the design process to find an optimal design of the interim support of the LCTS. The sensitivity of the design variables, such as thickness, height, and width of the plates, is investigated. The optimal design is obtained by a sequential quadratic programming algorithm based on a metamodel developed by randomly selected experimental samples. Through the design optimization process, the optimal design of the interim support of the LCTS support is obtained.