Eun Sub Kim

Eun Sub Kim

Auto-generated profile, based on publicly available information

Eun Sub Kim


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2023 in Developments in the Built Environment
Verified
Journal Article
Open access
EKEun Sub Kim
Eun Sub Kim
SYSeok Hwan Yun
Seok Hwan Yun
DLDong Kun Lee
Dong Kun Lee
NKNa Youn Kim
Na Youn Kim
ZPZheng Gang Piao
Zheng Gang Piao
SPSeunghwan Park
Seunghwan Park

28 November 2023 in Sustainable Cities and Society
Verified
Journal Article
Closed access
EKEun Sub Kim
Eun Sub Kim
SYSeok Hwan Yun
Seok Hwan Yun
JKJi Yeon Kim
Ji Yeon Kim
JTJames Thorne
James Thorne
JHJung Hee Hyun
Jung Hee Hyun
DLDong Kun Lee
Dong Kun Lee

31 August 2024 in Journal of Climate Change Research
Verified
Journal Article
Closed access
MZMengjia Zhao
Mengjia Zhao
EKEun Sub Kim
Eun Sub Kim
DLDong Kun Lee
Dong Kun Lee
Vertical greening systems (VGS) can effectively mitigate the urban heat island effect in urban canyons with dense high-rise buildings. This study evaluates the cooling effect of VGS on solar radiation and atmospheric temperature. A thermodynamic analysis was utilized to assess the impact of VGS on outdoor thermal comfort. CNR4 equipment collected data on long-wave and short-wave radiation from Fatsia japonica plants. These data formed the basis for simulation analyses with the Envi-met model, which showed that VGS exhibit significant diurnal surface temperature variations in the urban environment during the summer months. Areas with VGS had higher temperatures than those of high albedo walls (HAW) from 2:00 to 4:00 and recorded lower temperatures than those of HAW between 13:00 and 15:00. VGS absorb short-wave and long-wave radiation better than HAW. The average short-wave radiation of VGS is 43.91 W/h², compared to 31.50 W/h² for HAW, while the average long-wave radiation of VGS is 2.82 W/h², compared to -1.53 W/h² for HAW. Envi-met simulations indicate that the surface temperature of the VGS decreases after 15:00, to about 0.1°C cooler than HAW. The data from July 15 indicate that VGS significantly outperformed HAW in terms of cooling the maximum temperature at 13:00 and stabilizing the minimum temperature at 3:00. Furthermore, the extent of the cooling effect of the VGS was approximately 1.5 meters. This demonstrates that VGS, as an eco-friendly solution, can improve the urban thermal environment, increase the urban greening rate, and promote ecologically balanced development.

4 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YJYoonho Jeon
Yoonho Jeon
EKEun Sub Kim
Eun Sub Kim
DKDaseul Kim
Daseul Kim
HHHyemee Hwang
Hyemee Hwang
SJSae Yeon Jang
Sae Yeon Jang
DLDong Kun Lee
Dong Kun Lee
Rest breaks and shifts to cooler working hours are widely used to manage occupational heat exposure, but their protective capacity may diminish as warming raises heat exposure across the working day. Here we use an adaptation-tipping-point framework to quantify the warming levels at which scheduling-based measures become insufficient for heavy labor. We apply it to South Korea, a climatically heterogeneous temperate case study, using dynamically downscaled projections under four Shared Socioeconomic Pathways and 7.95 million workers in heavy-labor sectors. Without adaptation, areas holding 98 % of this workforce reach a 25 % seasonal labor-capacity-loss threshold within the analyzed range of Korea-wide annual-mean warming above 2000–2019, at a median of 5.99 °C. Mild loss emerges earlier: half the workforce reaches the 10 % threshold by 2041–2045 under every SSP, but the 25 % threshold only under SSP5-8.5, by 2085. Combining a 2-h work shift with heat-triggered rest cuts the at-risk share from 84 % to 2 % at the SSP5-8.5 2081–2100 mean of +6.4 °C, but the protection is finite: across the rest of the analyzed range the residual share rises to 67 % under the legal 20-min minimum and 29 % with 30 min. The limit binds unevenly: baseline humid heat advances the tipping point by 1.09 °C per standard deviation, and the areas left at residual risk tip about 1 °C earlier than those the measures protect. Scheduling-based adaptation therefore has a finite climatic limit, lying beyond end-of-century mean warming but within reach this century.