Center for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of Korea
Auto-generated profile, based on publicly available information
Dongmin Kim
Center for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of Korea
In the age of the Internet of Things, the proliferation of edge devices has resulted in a significant increase in personal information that is susceptible to theft and counterfeiting at various stages of data communication. As a result, substantial attention has been focused on hardware (HW) security elements, such as the true random number generator and physical unclonable function. With the recent surge in research and development of emerging memristors, which exploit the inherent variability of these devices, there has been a notable increase in studies on HW security. Particularly, volatile threshold switch (TS) devices, which exhibit insulator/metal characteristics below/above a certain threshold voltage, show great promise as security devices due to their lower power consumption and higher cycling endurance compared to nonvolatile memory devices. Despite the promising attributes and increasing demand for TS devices for HW security, there remains a lack of a comprehensive overview covering various TS devices and their potential contributions to HW privacy. To address this gap, this review provides an encompassing analysis of different types of TS devices and their performance in HW security literature, providing insight into current limitations and the future prospects of HW security primitives based on TS devices.
In this study, we investigated the impact of overshoot current (I over ) on the reliability of selector-only memory (SOM) devices based on an ovonic threshold switch (OTS). We found that implementing a multi-step pulse during the write operation reduced I over by 40%, significantly decreased threshold voltage (V th ) variability during the read process to ensure sufficient read window margin, and improved endurance by more than an order of magnitude, compared to the traditional square pulse. Our analysis revealed that the I over leads to increased I on variability, which in turn causes greater variability in the write pulse’s impact on subsequent read process. Furthermore, I over generates extra injection charge, which directly correlating with increased device stress and significantly impacting endurance. Through intermittent and continuous pulse measurements, we confirmed the critical role of I over in cycling stability. Our findings underscore the importance of suppressing I over to enhance SOM reliability, emphasizing the need for optimizing the multi-step pulse method.
From the perspective of developing low‐power mobile healthcare devices capable of real‐time electrogram diagnosis, memristor‐based physical reservoir computing (PRC) offers a promising alternative to conventional deep neural network (DNN)‐based systems. Here, real‐time electrocardiogram (ECG) monitoring and arrhythmia detection are demonstrated using electrochemical random‐access memory (ECRAM)‐based PRC. ECRAM devices provide the millisecond‐range temporal resolution required for bio‐potential signals like ECG. Through material and process engineering, it is identified that higher ionic conductivity (σion) in the electrolyte layer and lower ionic diffusivity (Dion) in the channel layer are crucial for achieving non‐linear dynamics and fading memory characteristics. In addition, LaF3/WOx‐based ECRAM exhibits low‐power operation (≈300 pW spike−1) with minimal cycle‐to‐cycle (CTC) variation (<10%). Arrhythmia detection tests confirmed the feasibility of real‐time ECG monitoring, achieving a high classification accuracy of 93.04% with a 50‐fold reduction in training parameters compared to DNN‐based systems. Therefore, the developed LaF3/WOx‐based ECRAM with engineering guidelines of ion dynamics makes a significant contribution to mobile healthcare systems for electrogram diagnosis.
For efficient training of embedded Edge-AI, we demonstrate a compact neuronal dropout by exploiting the inherent stochasticity of a highly scalable ovonic threshold switch (OTS). To implement reliable probabilistic operations, the random nature of OTS is intensively investigated, and a pre-set pulse scheme is presented. We verify successful dropout implementation by a mere 1T3R structure that controls the probability without requiring external circuits. Experimental results reveal its potential for edge applications (i.e., arrhythmia detection) by improving accuracies (up to 11.4 %) with limited training data (100 signals).
In this study, we investigated the influence of ultraviolet (UV) treatment on the ovonic threshold switch (OTS) to improve its selector properties. Our findings demonstrate that iteratively applying UV treatment during the film deposition phase considerably improves device characteristics compared to a single UV treatment. Consequently, this process provided a significant decrease in the forming voltage, maintaining outstanding switching features, with an off-state current of approximately 2 nA. Furthermore, the refined UV treatment process resulted in an impressive 45% improvement in threshold voltage drift characteristics and facilitated excellent switching uniformity. X-ray photoelectron spectroscopy analysis revealed alterations in the bonding structure of the Si–Te–As–Ge film after UV exposure. Specifically, a transition was observed from unstable homopolar bonds, such as As-As or Te–Te, to their more stable heteropolar equivalents, such as As–Te. These results highlight the potential of UV treatment as an effective method for enhancing the OTS performance.