Jackson Rodrigo Santos Silva

Jackson Rodrigo Santos Silva

Auto-generated profile, based on publicly available information

Jackson Rodrigo Santos Silva


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Revista Virtual de Química
Verified
Journal Article
Closed access
GCGuilherme H. S. Cândido
Guilherme H. S. Cândido
JSJackson R. S. Silva
Jackson R. S. Silva
MLMarcelo B. Lima
Marcelo B. Lima
RNRamom Rachide Nunes
Ramom Rachide Nunes

19 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
HSHelayne S. de Sousa
Helayne S. de Sousa
LMLuis Vinicius Gonçalves de Melo
Luis Vinicius Gonçalves de Melo
JSJackson Rodrigo Santos Silva
Jackson Rodrigo Santos Silva
FCFranciel da Silva Costa
Franciel da Silva Costa
SOSeverino Carlos Bezerra de Oliveira
Severino Carlos Bezerra de Oliveira
VSVagner Bezerra Dos Santos
Vagner Bezerra Dos Santos
5-Hydroxy-L-tryptophan (5-HTP), the direct precursor of serotonin, is a trace and analytically underexplored urinary biomarker. This study presents a new fluorescence digital image-based (FDIB) method for its determination in synthetic urine. Since the natural fluorescence of 5-HTP is weak, the compound was derivatized with dansyl chloride (5-HTP-DNS) in alkaline medium (pH 9.0, 50 °C, 60 min). The derivatized product was excited by a UV LED in a portable dark chamber, and the emitted fluorescence was captured by a smartphone, generating analytical signals from the RGB channels and an RGB vector. The vector showed superior sensitivity, exhibiting two linear ranges (0.05-0.50 and 0.50-5.00 nmol mL⁻¹) with detection limits of 10 and 80 pmol mL⁻¹, respectively. Intraday and interday relative standard deviations were 6.50% and 1.62%. Recoveries in synthetic urine ranged from 86% to 110%, with no statistically significant differences compared to the spectrofluorometric reference method. The digital images were processed using chemometric modeling: Hierarchical Cluster Analysis (HCA) revealed clear separation of 5-HTP from interfering compounds and the urinary matrix, while the supervised DD-SIMCA and PLS-DA models, built from RGB/HSV/grayscale intensity histograms, achieved 100% sensitivity, specificity, and accuracy in discriminating the analyte. Relative errors below ±15% were obtained in the univariate interference assay. Green chemistry metrics (AGREE = 0.86, GAPI = 86, BAGI = 80) confirmed the method's compliance with sustainability principles. The 5-HTP-DNS-FDIB method is sensitive, selective, portable, environmentally friendly, and has potential for point-of-care applications.