Vladimir Y. Yurov

Vladimir Y. Yurov

Auto-generated profile, based on publicly available information

Vladimir Y. Yurov

Prokhorov General Physics Institute of Russian Academy of Sciences, Vavilov str. 38, 119991 Moscow, Russia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2017 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
VYVladimir Yurov
Vladimir Yurov
EBEgor Bushuev
Egor Bushuev
ABAndrey Петрович Bolshakov
Andrey Петрович Bolshakov
EAEvgeny Ashkinazi
Evgeny Ashkinazi
IAIrina Antonova
Irina Antonova
Victor RalchenkoVictor Ralchenko
Victor Ralchenko

28 December 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
VYV. Yu. Yurov
V. Yu. Yurov
EBE. V. Bushuev
E. V. Bushuev
APA. F. Popovich
A. F. Popovich
ABAndrey Петрович Bolshakov
Andrey Петрович Bolshakov
EAE. E. Ashkinazi
E. E. Ashkinazi
VRV. G. Ralchenko
V. G. Ralchenko
We measured the refractive index n(T) and thermo-optical coefficient β(T) = (1/n)(dn/dT) of high quality synthetic diamonds from room temperature to high temperatures, up to 1520 K, in near-infrared spectral range at wavelength 1.56 μm, using a low-coherence interferometry. A type IIa single crystal diamond produced by high pressure–high temperature technique and a transparent polycrystalline diamond grown by chemical vapor deposition were tested and revealed a very close n(T) behavior, with n = 2.384 ± 0.001 at T = 300 K, monotonically increasing to 2.428 at 1520 K. The n(T) data corrected to thermal expansion of diamond are well fitted with 3rd order polynomials, and alternatively, with the Bose-Einstein model with an effective oscillator frequency of 970 cm−1. Almost linear n(T) dependence is observed above 800 K. The thermo-optical coefficient is found to increase monotonically from (0.6 ± 0.1) × 10−5 K−1 (300 K) to (2.0 ± 0.1) × 10−5 K−1 (1300 K) with a tendency to saturation at >1200 K. These β(T) values are an order of magnitude lower than those known for Si, GaAs, and InP. The obtained results significantly extend the temperature range, where the refractive index of diamond was previously measured.

17 February 2021 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
VYV. Yu. Yurov
V. Yu. Yurov
VRV. G. Ralchenko
V. G. Ralchenko
Artem MartyanovArtem Martyanov
Artem Martyanov
IAI. A. Antonova
I. A. Antonova
Vadim SedovVadim Sedov
Vadim Sedov
ABA. P. Bolshakov
A. P. Bolshakov
Microwave (MW) plasma in silane-hydrogen and silane-hydrogen-methane mixtures is used effectively for chemical vapor deposition of Si, SiC, diamond, and SiC-diamond composite films; however, the properties of such plasma at pressures of the order of 100 Torr remain largely unexplored. Here we characterize the MW plasma (2.45 GHz) in SiH4 + H2 and SiH4 + СH4 + H2 mixtures (72 Torr) with silane content ranging from 0% to 5% in the process gas using high-resolution optical emission (OE) spectroscopy. Besides the OE lines of C2 dimer, Balmer series of excited atomic hydrogen (Hα, Hβ, Hγ, Hδ, and Hε), and CH radical, we observed atomic Si lines at 263, 288, and 391 nm and a relatively weak SiH emission. Gas temperature Tg of ≈3160 K is assessed from the rotational structure of the C2 dimer (Δν = 0, λ = 516.5 nm) emission band, and the absorbed microwave power density (MWPD) in the plasma fluctuates in the narrow range between 36 and 43 W/cm3 with a slight tendency to decrease with silane addition. The MWPD, intensity ratio Hα/Hβ of hydrogen Balmer series lines (related to excitation temperature Texc), and Si lines’ intensities in OE spectra as functions of SiH4 concentration in H2 and H2 + CH4 mixtures all show an extremum or a kink in slope near a special point at ≈0.5% SiH4. Finally, we produced a silicon carbide film of cubic polytype 3C-SiC on a (111) oriented Si substrate, which was characterized with Raman spectroscopy and x-ray diffraction, and its monocrystalline structure was confirmed.

5 February 2022 in Vacuum
Verified
Journal Article
Closed access
VYV. Yu Yurov
V. Yu Yurov
ABAndrey Петрович Bolshakov
Andrey Петрович Bolshakov
AAA.S. Altakhov
A.S. Altakhov
IFI.A. Fedorova
I.A. Fedorova
EZE.V. Zavedeev
E.V. Zavedeev
VRV.G. Ralchenko
V.G. Ralchenko

26 June 2023 in Coatings
Verified
Journal Article
Open access
PDF file
EAEvgeny Ashkinazi
Evgeny Ashkinazi
SFSergey Fedorov
Sergey Fedorov
Artem MartyanovArtem Martyanov
Artem Martyanov
Vadim SedovVadim Sedov
Vadim Sedov
APAlexey Popovich
Alexey Popovich
VKVitaly I. Konov
Vitaly I. Konov
Conformal multilayer micro-nanocrystalline diamond coatings were grown on substrates of a hard alloy with 9% Co with a high aspect number in microwave plasma from gas mixtures CH4/H2 and CH4/H2/N2. The substrates were of a cylindrical axial tool model with a size ratio: d = 12 mm to l = 75 mm. An original tool holder made of molybdenum, in the form of a sector of the excessive ring with the axis of the hole parallel to the central conductive platform, protects part of the substrate from heating due to the edge effect of plasma. The uniformity of heating of the growth part, which is located inside the excessive ring, is calculated using mathematical modeling and is provided by rotation at a speed of at least 12 rpm, which ensures the uniformity of the coating. The average grain size of the nanocrystalline film measured along the cylinder forming was 41 nm.

4 August 2017 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
VYV.Yu. Yurov
V.Yu. Yurov
EBE.V. Bushuev
E.V. Bushuev
ABA.P. Bolshakov
A.P. Bolshakov
IAI.A. Antonova
I.A. Antonova
VRV.G. Ralchenko
V.G. Ralchenko
VKV.I. Konov
V.I. Konov
EPJ Web of Conferences, open-access proceedings in physics and astronomy