Center for Human Ophthalmic Imaging Research (CHOIR), Department of Ophthalmology and Vision Science, University of California, Davis, 4860 Y Street, Sacramento, 95817, California, USA
Auto-generated profile, based on publicly available information
Maciej M. Bartuzel
Center for Human Ophthalmic Imaging Research (CHOIR), Department of Ophthalmology and Vision Science, University of California, Davis, 4860 Y Street, Sacramento, 95817, California, USA
We introduce a novel, noninvasive retinal eye-tracking system capable of detecting eye displacements with an angular resolution of 0.039 arcmin and a maximum velocity of 300°/s across an 8° span. Our system is designed based on a confocal retinal imaging module similar to a scanning laser ophthalmoscope. It utilizes a 2D MEMS scanner ensuring high image frame acquisition frequencies up to 1.24 kHz. In contrast with leading eye-tracking technology, we measure the eye displacements via the collection of the observed spatial excursions for all the times corresponding a full acquisition cycle, thus obviating the need for both a baseline reference frame and absolute spatial calibration. Using this approach, we demonstrate the precise measurement of eye movements with magnitudes exceeding the spatial extent of a single frame, which is not possible using existing image-based retinal trackers. We describe our retinal tracker, tracking algorithms and assess the performance of our system by using programmed artificial eye movements. We also demonstrate the clinical capabilities of our system with in vivo subjects by detecting microsaccades with angular extents as small as 0.028°. The rich kinematic ocular data provided by our system with its exquisite degree of accuracy and extended dynamic range opens new and exciting avenues in retinal imaging and clinical neuroscience. Several subtle features of ocular motion such as saccadic dysfunction, fixation instability and abnormal smooth pursuit can be readily extracted and inferred from the measured retinal trajectories thus offering a promising tool for identifying biomarkers of neurodegenerative diseases associated with these ocular symptoms.
We present a calibration method for finding the coordinates of points in the trajectory of the scanning beam in flying-spot imaging devices. Our method is based on laterally translating the field of view on the imaging object plane by introducing additional beam deflections. We show that laterally translating the field of view provides a series of images whose relative translations are equal to the distances between the points in the scanning pattern to be calibrated. We show how these distances are mapped to the coordinates of the trajectory points. As an example, we demonstrate the calibration of the scanning patterns in an optical system with two independent microelectromechanical system based scanners. Our method profits from a large collection of distance measurements to find the trajectory coordinates, thereby minimizing the effect of random sources of uncertainty in the positions of points in the scanning pattern. We have found that we are capable of finding the coordinates of points in the scanning patterns with accuracy greater than the optical resolution of the imaging system.
Optoretinography (ORG) is a class of methods that use noninvasive, all-optical techniques to measure stimulus-evoked responses in the retina. By conveying functional and structural information at once, it offers a valuable complement to existing functional assays such as visual acuity, visual fields, and electroretinography. Whether employed in basic scientific research or clinical testing, the utility of ORG depends on its sensitivity to changes in the cone response. This sensitivity depends in part on the intrinsic variation of photoreceptor responses. In ORG studies using adaptive optics (AO), single cone responses are sometimes reported, but more often the responses of many cones are pooled in a defined field of view (FOV) to convey an average cone response with improved signal-to-noise ratio (SNR). In this study, we quantify repeatability of cellular-resolution ORG measurements made with adaptive optics (AO) optical coherence tomography (OCT). First, we describe a model-fitting method for parameterizing and quantifying the ORG responses. Next, using model-derived parameters, we investigate two kinds of repeatability: among repeated measurements of individual cones and among repeated measurements of the pooled responses of cones in a 1° field of view. Repeated measurements of individual cones exhibited good consistency in the ORG amplitude. Although responses among neighboring cones can differ greatly, pooled responses of cones from the same field of view were highly repeatable for maximum outer segment elongation and the elongation rate. Both kinds of repeatability were assessed using the same data sets; test-retest pairs were acquired within 30-minute windows in an effort to isolate measurement noise from physiological changes that may be more appropriately considered signal. These findings demonstrate AO-OCT-ORG’s potential value in detecting changes in cone response due to experimental or therapeutic interventions, and its value in measuring longitudinal disease-related changes in response.
1 Water movement in the living human retina and its regulation are important components of the tissue’s structural integrity, optical properties, and homeostasis. In the outer retina there is a continuous flow of water from the subretinal space, through the retinal pigmented epithelium, and into the choroid. This flow is disrupted acutely in disorders such as retinal detachment and central serous retinopathy, and is also known to reduce dramatically with age and age-related macular degeneration. Optoretiongraphy is an emerging technique for measuring neural function in the retina by monitoring nanometer-scale deformations of the membranes of photoreceptors. These deformations have been hypothetically attributed, in part, to osmotic shifts that cause water to move into and out of the photoreceptor outer segment after light stimulation. In the present work, we describe a method for measuring changes in the lengths of the cone outer segment and subretinal space in parallel and results showing that light stimuli change the volume of the subretinal space. These results are consistent with earlier ex vivo measurements of its light-induced hydration. The magnitude of the latter changes depend on the rate of water clearance from the subretinal space, and thus may serve as an indicator of the health of the water transport system. In addition, they may help us understand the mechanisms underlying the photoreceptor optoretinogram. These findings add to a growing understanding of the ways in which light exposure leads to transient reconfigurations of the outer retinal layers lasting milliseconds to hours.