Emily Debrot

Emily Debrot

Auto-generated profile, based on publicly available information

Emily Debrot

Centre for Medical Radiation Physics, University of Wollongong, Wollongong 2500, Australia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
EDE Debrot
E Debrot
LTLinh Tran
Linh Tran
LCL Chartier
L Chartier
DBD Bolst
D Bolst
SGSusanna Guatelli
Susanna Guatelli
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
With more patients receiving external beam radiation therapy with protons, it becomes increasingly important to refine the clinical understanding of the relative biological effectiveness (RBE) for dose delivered during treatment. Treatment planning systems used in clinics typically implement a constant RBE of 1.1 for proton fields irrespective of their highly heterogeneous linear energy transfer (LET). Quality assurance tools that can measure beam characteristics and quantify or be indicative of biological outcomes become necessary in the transition towards more sophisticated RBE weighted treatment planning and for verification of the Monte Carlo and analytical based models they use. In this study the RBE for the CHO-K1 cell line in a passively delivered clinical proton spread out Bragg peak (SOBP) is determined both in vitro and using a silicon-on-insulator (SOI) microdosimetry method paired with the modified microdosimetric kinetic model. The RBE along the central axis of a SOBP with 2 Gy delivered at the middle of the treatment field was found to vary between 1.11–1.98 and the RBE for 10% cell survival between 1.07–1.58 with a 250 kVp x-ray reference radiation and between 1.19–2.34 and 0.95–1.41, respectively, for a Co60 reference. Good agreement was found between RBE values calculated from the SOI-microdosimetry-MKM approach and in vitro . A strong correlation between proton lineal energy and RBE was observed particularly in the distal end and falloff of the SOBP.

30 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LTLinh Tran
Linh Tran
DBDavid Bolst
David Bolst
BJBenjamin James
Benjamin James
VPVladimir Pan
Vladimir Pan
JVJames Vohradsky
James Vohradsky
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. 3D SVs were fabricated in different sizes and configurations with diameters between 18 and 30 µm, thicknesses of 2–50 µm and at a pitch of 50 µm in matrices with volumes of 20 × 20 and 50 × 50. SVs were segmented into sub-arrays to reduce capacitance and avoid pile up in high-dose rate pencil beam scanning applications. Detailed TCAD simulations and charge collection studies in individual SVs have been performed. The microdosimetry probe (MicroPlus) is composed of the silicon microdosimeter and low-noise front–end readout electronics housed in a PMMA waterproof sheath that allows measurements of lineal energies as low as 0.4 keV/µm in water or PMMA. Microdosimetric quantities measured with SOI microdosimeters and the MicroPlus probe were used to evaluate the relative biological effectiveness (RBE) of heavy ions and protons delivered by pencil-beam scanning and passive scattering systems in different particle therapy centres. The 3D detectors and MicroPlus probe developed for microdosimetry have the potential to provide confidence in the delivery of RBE optimized particle therapy when introduced into routine clinical practice.

1 April 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
APAlessio Parisi
Alessio Parisi
SCSabina Chiriotti
Sabina Chiriotti
MSMarijke De Saint-Hubert
Marijke De Saint-Hubert
OHOlivier Van Hoey
Olivier Van Hoey
CVCharlot Vandevoorde
Charlot Vandevoorde
FVFilip Vanhavere
Filip Vanhavere
A new methodology for assessing linear energy transfer (LET) and relative biological effectiveness (RBE) in proton therapy beams using thermoluminescent detectors is presented. The method is based on the different LET response of two different lithium fluoride thermoluminescent detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) for measuring charged particles. The relative efficiency of the two detector types was predicted using the recently developed Microdosimetric d ( z ) Model in combination with the Monte Carlo code PHITS. Afterwards, the calculated ratio of the expected response of the two detector types was correlated with the fluence- and dose- mean values of the unrestricted proton LET. Using the obtained proton dose mean LET as input, the RBE was assessed using a phenomenological biophysical model of cell survival. The aforementioned methodology was benchmarked by exposing the detectors at different depths within the spread out Bragg peak (SOBP) of a clinical proton beam at iThemba LABS. The assessed LET values were found to be in good agreement with the results of radiation transport computer simulations performed using the Monte Carlo code GEANT4. Furthermore, the estimated RBE values were compared with the RBE values experimentally determined by performing colony survival measurements with Chinese Hamster Ovary (CHO) cells during the same experimental run. A very good agreement was found between the results of the proposed methodology and the results of the in vitro study.

19 December 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
EDEmily Debrot
Emily Debrot
MNMatthew Newall
Matthew Newall
SGSusanna Guatelli
Susanna Guatelli
MPMarco Petasecca
Marco Petasecca
NMNaruhiro Matsufuji
Naruhiro Matsufuji
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

21 January 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
EDEmily Debrot
Emily Debrot
DBDavid Bolst
David Bolst
BJBenjamin James
Benjamin James
LTLinh Tran
Linh Tran
SGSusanna Guatelli
Susanna Guatelli
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
An experimental and simulation-based study was performed on a C-12 ion minibeam radiation therapy (MBRT) field produced with a clinical broad beam and a brass multi-slit collimator (MSC). Silicon-on-insulator (SOI) microdosimeters developed at the Centre for Medical Radiation Physics (CMRP) with micron sized sensitive volumes were used to measure the microdosimetric spectra at varying positions throughout the MBRT field and the corresponding dose-mean lineal energies and RBE for 10% cell survival (RBE10) were calculated using the modified Microdosimetric Kinetic Model (MKM). An increase in the average RBE10 of similar to 30% and 10% was observed in the plateau region compared to broad beam for experimental and simulation values, respectively. The experimental collimator misalignment was determined to be 0.7 degrees by comparison between measured and simulated microdosimetric spectra at varying collimator angles. The simulated dose-mean lineal energies in the valley region between minibeams were found to be higher on average than in the minibeams due to higher LET particles being produced in these regions from the MSC. This work presents the first experimental microdosimetry measurements and characterisation of the local biological effectiveness in a MBRT field.

8 November 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
VPV. A. Pan
V. A. Pan
JVJ. Vohradsky
J. Vohradsky
BJB. James
B. James
FPF. Pagani
F. Pagani
LCL. Chartier
L. Chartier
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
Radiation monitoring in space radiation is complex due to galactic cosmic rays (GCRs), solar particle events (SPEs), and albedo particles. Thermal neutrons are an important component in the Moon radiation albedo field which can cause single event upset (SEU) in electronics when they interact with the 10 B present in electronic components. In this work, we studied an application of silicon on insulator (SOI) microdosimeters for neutron monitoring in various mixed radiation field environments. A 10- $\mu \text{m}$ SOI microdosimeter was utilized in conjunction with a 10 B 4 C thin-film converter to successfully measure the thermal neutron contribution out of field of a therapeutic proton beam as well as an 18-MV X-ray linear accelerator (LINAC). The microdosimeter was placed downstream of the Bragg peak (BP) as well as laterally out of field of the proton beam and at two positions along the treatment couch of the 18-MV LINAC. It was demonstrated that the 10- $\mu \text{m}$ SOI microdosimeter with 10 B 4 C converter is suitable for detection of thermal neutrons with excellent discrimination of gamma, fast and thermal neutron components in the presence of a gamma-neutron pulsed field of an 18-MV LINAC. To reduce the gamma contribution and further improve detection of neutrons in mixed radiation fields, a new $2 ~\mu \text{m}$ Mushroom-planar microdosimeter was fabricated and characterized in detail using an ion beam induced charge collection (IBIC) technique with 1.78 MeV $\text{H}e^{\mathrm {2+}}$ ions. It was demonstrated that this $2 ~\mu \text{m}$ SOI microdosimeter can be operated in a passive mode. The SOI microdosimeter with the 10 B 4 C converter can be recommended for the detection of thermal neutrons for SEU prediction in the mixed gamma-neutron fields during space missions, especially for the Moon mission.