Marco Petasecca

Prof. Dr. Marco Petasecca

University of Wollongong, Wollongong, New South Wales, Australia
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Physica Medica
Verified
Journal Article
Open access
EBElke Bräuer-Krisch
Elke Bräuer-Krisch
JAJean-Francois Adam
Jean-Francois Adam
EAEnver Alagoz
Enver Alagoz
Stefan BartzschStefan Bartzsch
Stefan Bartzsch
JCJeff Crosbie
Jeff Crosbie
BSBjarne Stugu
Bjarne Stugu
Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. Although the techniques differ by their principles, SSRT and MRT share certain common aspects with the possibility of combining their advantages in the future. For MRT, the technique uses highly collimated, quasi-parallel arrays of X-ray microbeams between 50 and 600 keV. Important features of highly brilliant Synchrotron sources are a very small beam divergence and an extremely high dose rate. The minimal beam divergence allows the insertion of so called Multi Slit Collimators (MSC) to produce spatially fractionated beams of typically ∼25-75 micron-wide microplanar beams separated by wider (100-400 microns center-to-center(ctc)) spaces with a very sharp penumbra. Peak entrance doses of several hundreds of Gy are extremely well tolerated by normal tissues and at the same time provide a higher therapeutic index for various tumor models in rodents. The hypothesis of a selective radio-vulnerability of the tumor vasculature versus normal blood vessels by MRT was recently more solidified. SSRT (Synchrotron Stereotactic Radiotherapy) is based on a local drug uptake of high-Z elements in tumors followed by stereotactic irradiation with 80 keV photons to enhance the dose deposition only within the tumor. With SSRT already in its clinical trial stage at the ESRF, most medical physics problems are already solved and the implemented solutions are briefly described, while the medical physics aspects in MRT will be discussed in more detail in this paper.

16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MPMarco Petasecca
Marco Petasecca
FMFrancesco Moscatelli
Francesco Moscatelli
Daniele PasseriDaniele Passeri
Daniele Passeri
GPG.U. Pignatel
G.U. Pignatel
In the framework of the CERN-RD50 Collaboration, the adoption of p-type substrates has been proposed as a suitable mean to improve the radiation hardness of silicon detectors up to fluencies of 1times10 16 n/cm2. In this work two numerical simulation models will be presented for p-type and n-type silicon detectors, respectively. A comprehensive analysis of the variation of the effective doping concentration (Neff), the leakage current density and the charge collection efficiency as a function of the fluence has been performed using the Synopsys T-CAD device simulator. The simulated electrical characteristics of irradiated detectors have been compared with experimental measurements extracted from the literature, showing a very good agreement. The predicted behaviour of p-type silicon detectors after irradiation up to 1016 n/cm2 shows better results in terms of charge collection efficiency and full depletion voltage, with respect to n-type material, while comparable behaviour has been observed in terms of leakage current density

18 April 2012 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
IFI. Fuduli
I. Fuduli
MCM. Carolan
M. Carolan
MPMarco Petasecca
Marco Petasecca
MLMichael Lerch
Michael Lerch
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

8 September 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
LTLinh Tran
Linh Tran
LCLachlan Chartier
Lachlan Chartier
DBDavid Bolst
David Bolst
APAlex Pogossov
Alex Pogossov
SGSusanna Guatelli
Susanna Guatelli
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

1 April 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
mara bruzzimara bruzzi
mara bruzzi
JAJ. Adey
J. Adey
AAA. Al-Ajili
A. Al-Ajili
PAP. Alexandrov
P. Alexandrov
GAG. Alfieri
G. Alfieri
NZNicola Zorzi
Nicola Zorzi

23 March 2018 in Medical Physics
Verified
Journal Article
Open access
PDF file
LTLinh Tran
Linh Tran
DBDavid Bolst
David Bolst
SGSusanna Guatelli
Susanna Guatelli
APAlex Pogossov
Alex Pogossov
MPMarco Petasecca
Marco Petasecca
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
Background: The aim of this study was to measure the microdosimetric distributions of a carbon pencil beam scanning (PBS) and passive scattering system as well as to evaluate the relative biological effectiveness (RBE) of different ions, namely 12C, 14N, and 16O, using a silicon‐on‐insulator (SOI) microdosimeter with well‐defined 3D‐sensitive volumes (SV). Geant4 simulations were performed with the same experimental setup and results were compared to the experimental results for benchmarking.Method: Two different silicon microdosimeters with rectangular parallelepiped and cylindrical shaped SVs, both 10 μm in thickness were used in this study. The microdosimeters were connected to low noise electronics which allowed for the detection of lineal energies as low as 0.15 keV/μm in tissue. The silicon microdosimeters provide extremely high spatial resolution and can be used for in‐field and out‐of‐field measurements in both passive scattering and PBS deliveries. The response of the microdosimeters was studied in 290 MeV/u 12C, 180 MeV/u 14N, 400 MeV/u 16O passive ion beams, and 290 MeV/u 12C scanning carbon therapy beam at heavy ion medical accelerator in Chiba (HIMAC) and Gunma University Heavy Ion Medical Center (GHMC), Japan, respectively. The microdosimeters were placed at various depths in a water phantom along the central axis of the ion beam, and at the distal part of the Spread Out Bragg Peak (SOBP) in 0.5 mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the microdosimetric lineal energy spectra and the modified microdosimetric kinetic model (MKM), using MKM input parameters corresponding to human salivary gland (HSG) tumor cells. Geant4 simulations were performed in order to verify the calculated depth‐dose distribution from the treatment planning system (TPS) and to compare the simulated dose‐mean lineal energy to the experimental results.Results: For a 180 MeV/u 14N pristine BP, the dose‐mean lineal energy obtained with two types of silicon microdosimeters started from approximately 29 keV/μm at the entrance to 92 keV/μm at the BP, with a maximum value in the range of 412 to 438 keV/μm at the distal edge. For 400 MeV/u 16O ions, the dose‐mean lineal energy started from about 24 keV/μm at the entrance to 106 keV/μm at the BP, with a maximum value of approximately 381 keV/μm at the distal edge. The maximum derived RBE10 values for 14N and 16O ions were found to be 3.10 ± 0.47 and 2.93 ± 0.45, respectively. Silicon microdosimetry measurements using pencilbeam scanning 12C ions were also compared to the passive scattering beam.Conclusions: These SOI microdosimeters with well‐defined three‐dimensional (3D) SVs have applicability in characterizing heavy ion radiation fields and measuring lineal energy deposition with sub‐millimeter spatial resolution. It has been shown that the dose‐mean lineal energy increased significantly at the distal part of the BP and SOBP due to very high LET particles. Good agreement was observed for the experimental and simulation results obtained with silicon microdosimeters in 14N and 16O ion beams, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in charged particle therapy.