Nicolas Gross-Weege

Nicolas Gross-Weege

Auto-generated profile, based on publicly available information

Nicolas Gross-Weege

RWTH Aachen University

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2016 in Medical Physics
Verified
Journal Article
Closed access
NGNicolas Gross‐Weege
Nicolas Gross‐Weege
DSDavid Schug
David Schug
PHPatrick Hallen
Patrick Hallen
VSVolkmar Schulz
Volkmar Schulz

24 January 2018 in Medical Physics
Verified
Journal Article
Open access
PDF file
NGNicolas Gross‐Weege
Nicolas Gross‐Weege
TDThomas Dey
Thomas Dey
PGPierre Gebhardt
Pierre Gebhardt
DSDavid Schug
David Schug
BWBjoern Weissler
Bjoern Weissler
VSVolkmar Schulz
Volkmar Schulz
Purpose: In order to integrate electronic devices into a magnetic resonance imaging (MRI) scanner, shielding of the electronics with respect to the radio frequency (RF) transmit and receive system of the MRI scanner is required. Furthermore, MRI uses time‐varying low‐frequency magnetic fields for spatial encoding, i.e., the gradient magnetic fields. Time‐varying magnetic fields induce eddy currents in all conductive elements. The eddy currents result in opposing magnetic fields, which can cause distortions of the magnetic resonance (MR) image. As shielding of lower frequencies is not feasible in this respect, an ideal shielding element should be transparent for gradient magnetic fields while providing a high RF shielding effectiveness. Furthermore, it should offer a low susceptibility to prevent distortion of the main magnetic field of the MRI. In this work, we characterize the aforesaid shielding parameters of different shielding samples.Methods: We developed a nuclear magnetic resonance (NMR) probe to measure the magnetic fields to quantify the field distortions time‐resolvedly. The relative distortion was introduced as a proportionality constant relating the eddy‐current‐inducing field changes and the field distortions. The relative distortion was measured in the frequency range from 0 to 10 kHz for all shielding samples using the NMR probe. We characterized the shielding effectiveness of the samples in the frequency range from 1 to 150 MHz using a network analyzer. We conducted all measurements with three different materials, two carbon fiber composites and copper, each in various thicknesses.Results: The relative distortion of the magnetic fields induced by the carbon fiber composites samples was at least a factor of seven lower than the copper sample. A linear dependency on the sample thickness was measured for the main field distortion, the relative distortion and the shielding effectiveness. The relative distortion was roughly independent of the gradient frequency contrary to the shielding effectiveness, highly depending on the RF frequency.Conclusions: We presented a very sensitive method to characterize the distortion of the main field distortion and the gradient transparency using an NMR probe. We analyzed different shielding materials regarding the main field distortion, the gradient transparency, and the shielding effectiveness. From the tested materials, we identified a carbon fiber composite with the lowest distortion on the MRI.

28 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LYLaiyin Yin
Laiyin Yin
FSFranziska Schrank
Franziska Schrank
NGNicolas Gross-Weege
Nicolas Gross-Weege
DSDavid Schug
David Schug
VSVolkmar Schulz
Volkmar Schulz
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B 0 ) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B 0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B 0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.

22 July 2025 in bioRxiv
Verified
Preprint
Open access
UHUlrike Horn
Ulrike Horn
SVS. Johanna Vannesjo
S. Johanna Vannesjo
NGNicolas Gross-Weege
Nicolas Gross-Weege
RTRobert Trampel
Robert Trampel
YRYulia Revina
Yulia Revina
FEFalk Eippert
Falk Eippert
Developments in functional magnetic resonance imaging (fMRI) at ultra-high field (UHF) now allow for insights into human brain function at mesoscopic scale. However, similar progress has not been achieved for the human spinal cord, despite its importance for reciprocal brain-body communication. Here, we therefore integrate substantial methodological improvements that enable previously unattainable high-resolution UHF spinal fMRI. Using a heat-pain paradigm in healthy volunteers, we investigate fMRI responses in the dorsal horn: we characterize their spatial pattern, establish their robustness and demonstrate that they can be reliably observed even for individual participants. Most importantly, we uncover two physiologically relevant spinal response components – phasic and tonic heat responses – that map differentially onto superficial and deep layers of the dorsal horn. Taken together, our novel UHF fMRI approach allows for differentiating responses across fundamental spinal processing units and will enable insights into human spinal cord function at mesoscopic scale in health and disease.

18 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
NGNicolas Gross-Weege
Nicolas Gross-Weege
TNTeresa Nolte
Teresa Nolte
VSVolkmar Schulz
Volkmar Schulz
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) by using PET inserts in existing MRI scanners is an attractive approach. When designing the PET insert, mutual influences of both imaging modalities need to be minimized. The gradient magnetic fields induce eddy currents in all conductive components of the PET insert. Eddy currents produce superimposing magnetic fields distorting the gradient magnetic field. However, the gradient magnetic fields determine how the MRI data is acquired in the k-space. A distorted gradient shape produces a distorted k-space trajectory which then results in a distorted image. The dynamic performance of the gradient system can be characterized by measuring its gradient impulse response function (GIRF). Knowledge of the GIRF enables to correct the k-space trajectory and thereby enables to reduce image distortions. We characterized the influence of a preclinical PET insert, the Hyperion IID, on the gradient performance of a 3-T MRI scanner. The GIRFs up to the second order spherical harmonics were determined with and without the PET insert by measuring frequency-swept gradient pulses with an NMR probe. We calculated a corrected k-space trajectory of a single-shot spiral sequence using the measured GIRFs. The low-pass characteristic of the gradient system only slightly increased in the presence of the PET insert. We showed a minor influence of the PET insert on the GIRFs, demonstrating the high gradient transparency of the PET insert. The single-shot spiral image measured in the presence of the PET insert and reconstructed with the uncorrected k-space trajectory was blurred and distorted. We strongly reduced the blurring and distortion by using the corrected k-space trajectory predicted with the measured GIRFs up to the first order spherical harmonics. Slight blurring remained in the corrected image caused by either second order spherical harmonics or distortions of the static magnetic field.

29 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TNTeresa Nolte
Teresa Nolte
HSHannah Scholten
Hannah Scholten
NGNicolas Gross‐Weege
Nicolas Gross‐Weege
TAThomas Amthor
Thomas Amthor
PKPeter Koken
Peter Koken
VSVolkmar Schulz
Volkmar Schulz
Purpose: Magnetic resonance fingerprinting (MRF) offers rapid quantitative imaging but may be subject to confounding effects (CE) if these are not included in the model‐based reconstruction. This study characterizes the influence of in‐plane , slice profile and diffusion effects on T1 and T2 estimation in the female breast at 1.5T.Methods: Simulations were used to predict the influence of each CE on the accuracy of MRF and to investigate the influence of electronic noise and spiral aliasing artefacts. The experimentally observed bias in regions of fibroglandular tissue (FGT) and fatty tissue (FT) was analyzed for undersampled spiral breast MRF data of 6 healthy volunteers by performing MRF reconstruction with and without a CE.Results: Theoretic analysis predicts T1 under‐/T2 overestimation if the nominal flip angles are underestimated and inversely, T1 under‐/T2 overestimation if omitting slice profile correction, and T1 under‐/T2 underestimation if omitting diffusion in the signal model. Averaged over repeated signal simulations, including spiral aliasing artefacts affected precision more than accuracy. Strong in‐plane effects occurred in vivo, causing T2 left–right inhomogeneity between both breasts. Their correction decreased the T2 difference from 29 to 5 ms in FGT and from 29 to 9 ms in FT. Slice profile correction affected FGT T2 most strongly, resulting in −22% smaller values. For the employed spoiler gradient strengths, diffusion did not affect the parameter maps, corresponding well with theoretic predictions.Conclusion: Understanding CEs and their relative significance for an MRF sequence is important when defining an MRF signal model for accurate parameter mapping.