Mohammad Rahim Sobhani

Mohammad Rahim Sobhani

Auto-generated profile, based on publicly available information

Mohammad Rahim Sobhani

Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
MSMohammad Rahim Sobhani
Mohammad Rahim Sobhani
MGMahyar Ghavami
Mahyar Ghavami
AIAfshin Kashani Ilkhechi
Afshin Kashani Ilkhechi
JBJeremy Brown
Jeremy Brown
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Top-orthogonal-to-bottom electrode (TOBE) arrays, also known as row–column arrays, have shown great promise as an alternative to fully wired 2-D arrays, owing to a considerable reduction in channels. Novel imaging schemes with bias-switchable TOBE arrays were previously shown to offer promise compared with previous nonbias-switchable row–column imaging schemes and compared with previously developed explososcan methods, however, they required significant coherent compounding. Here, we introduce ultrafast orthogonal row–column electronic scanning (uFORCES), an ultrafast coded synthetic aperture imaging method. Unlike its FORCES predecessor, uFORCES can achieve coherent compounding with only a few transmit events and may, thus, be more robust to tissue motion. We demonstrate through simulations that uFORCES can potentially offer improved resolution compared with the matrix probes having beamformers constrained by the paraxial approximation. Also, unlike current matrix probe technology incorporating microbeamforming, uFORCES with bias-switchable TOBE arrays can achieve ultrafast imaging at thousands of frames per second using only row and column addressing. We also demonstrate the experimental implementation of uFORCES using a fabricated $128 \times 128$ electrostrictive TOBE array on a crossed 25- $\mu \text{m}$ gold wire phantom and a tissue-mimicking phantom. The potential for improved resolution and ultrafast imaging with uFORCES could enable new essential imaging capabilities for clinical and preclinical ultrasound.

8 November 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
MGMahyar Ghavami
Mahyar Ghavami
MSMohammad Rahim Sobhani
Mohammad Rahim Sobhani
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
The opaque ultrasound transducers used in conventional photoacoustic imaging systems necessitate oblique light delivery, which gives rise to some disadvantages such as inefficient target illumination and bulky system size. This work proposes a transparent capacitive micromachined ultrasound transducer (CMUT) linear array with dual-band operation for through-illumination photoacoustic imaging. Fabricated using an adhesive wafer bonding method, the array consists of optically transparent conductors (ITO) as both top and bottom electrodes, a transparent polymer (BCB) as the sidewall and adhesive material, and largely transparent silicon nitride as the membrane. The fabricated device had a maximum optical transparency of 76.8% in the visible range. Furthermore, to simultaneously maintain higher spatial resolution and deeper imaging depth, this dual-frequency array consists of low and high frequency channels with 4.2 and 9.3 MHz center frequencies, respectively, which are configured in an interlaced architecture to minimize the grating lobes in the receive point spread function. With a wider bandwidth compared to the single frequency case, the fabricated transparent dual-frequency CMUT array was used in through-illumination photoacoustic imaging of wire targets demonstrating an improved spatial resolution and imaging depth.

22 February 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
AIAfshin Kashani Ilkhechi
Afshin Kashani Ilkhechi
RPRandy Palamar
Randy Palamar
MSMohammad Rahim Sobhani
Mohammad Rahim Sobhani
DDDarren Dahunsi
Darren Dahunsi
CCChristopher Ceroici
Christopher Ceroici
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Top Orthogonal to Bottom Electrode (TOBE) arrays, also known as row-column arrays, hold great promise for fast high-quality volumetric imaging. Bias-voltage-sensitive TOBE arrays based on electrostrictive relaxors or micromachined ultrasound transducers can enable readout from every element of the array using only row and column addressing. However, these transducers require fast bias-switching electronics which are not part of a conventional ultrasound system and are non-trivial. Here we report on the first modular bias-switching electronics enabling transmit, receive, and biasing on every row and every column of TOBE arrays, supporting up to 1024 channels. We demonstrate the performance of these arrays by connection to a transducer testing interface board and demonstrate 3D structural imaging of tissue and 3D power Doppler imaging of phantoms with realtime B-scan imaging and reconstruction rates. Our developed electronics enable interfacing of bias-switchable TOBE arrays to channel-domain ultrasound platforms with software-defined reconstruction for next-generation 3D imaging at unprecedented scales and imaging rates.

7 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SKShayan Khorassany
Shayan Khorassany
EDEric B. Dew
Eric B. Dew
MSMohammad Rahim Sobhani
Mohammad Rahim Sobhani
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Recently, capacitive micromachined ultrasound transducers (CMUTs) with long rectangular membranes have demonstrated performance advantages over conventional piezoelectric transducers; however, modeling these CMUT geometries has been limited to computationally burdensome numerical methods. Improved fast modeling methods, such as equivalent circuit models, could help achieve designs with even better performance. The primary obstacle in developing such methods is the lack of tractable methods for computing the radiation impedance of clamped rectangular radiators. This paper presents a method that approximates the velocity profile using a polynomial shape model to rapidly and accurately estimate radiation impedance. The validity of the approximate velocity profile and corresponding radiation impedance calculation was assessed using finite element simulations for a variety of membrane aspect ratios and bias voltages. Our method was evaluated for rectangular radiators with width:length ratios from 1:1 up to 1:25. At all aspect ratios, the radiation resistance was closely modeled. However, when calculating the radiation reactance, our initial approach was only accurate for low aspect ratios. This motivated us to consider an alternative shape model for high aspect ratios, which was more accurate when compared with FEM. To facilitate the development of future rectangular CMUTs, we provide a MATLAB script that quickly calculates radiation impedance using both methods.

20 May 2025 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
EDEric B. Dew
Eric B. Dew
SKShayan Khorassany
Shayan Khorassany
MGMahyar Ghavami
Mahyar Ghavami
MSMohammad Rahim Sobhani
Mohammad Rahim Sobhani
MMMohammad Maadi
Mohammad Maadi
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Capacitive micromachined ultrasound transducers (CMUTs) are typically designed with many small membranes per linear array element. However, these membranes can operate out of phase or collapse at different voltages, leading to suboptimal transmit performance and unreliable operation. To avoid these problems, we recently proposed a CMUT architecture with a single large rectangular membrane per element and novel insulated electrode post structures. These single-membrane CMUTs outperformed comparable piezoelectric transducers by almost 3-fold in terms of output pressure and demonstrated electromechanical efficiency values as high as 0.95. In this paper, we present an analytical model which can be used to simulate and optimize single-membrane rectangular CMUTs with or without post structures. Our approach relies on a polynomial deflection model, which was used to derive lumped element model parameters. Using this method, we developed expressions to model both electrostatic and pre-collapse small-signal dynamic CMUT behavior. This modeling framework was incorporated into a MATLAB program. We validated our approach using finite element method (FEM) simulations and experimental results in both air and immersion media. Model predictions for collapse voltage and operating frequency are within 4% of FEM results in both air and immersion. However, the runtime of our MATLAB program was 6 orders of magnitude faster than the corresponding FEM simulations. Compared with experiment, collapse voltage predictions were within 8%, and operating frequency predictions were within 5% in air and 18% in soybean oil. Our results indicate that that rectangular CMUTs may be optimized much further, potentially enabling even greater improvements over piezoelectric transducers.

1 January 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Open access
THTyler Keith Henry
Tyler Keith Henry
DDDarren Dahunsi
Darren Dahunsi
RPRandy Palamar
Randy Palamar
NMNegar Majidi
Negar Majidi
YWYing Wan
Ying Wan
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Hadamard matrix-based aperture encoding is a method for producing synthetic aperture datasets with high signal-to-noise ratios (SNRs). Recently, the pulse inversion capabilities of bias-sensitive top-orthogonal-to-bottom-electrode (TOBE) arrays have driven the development of multiple Hadamard-based sequences. These sequences produce high-quality static images but are sensitive to motion. This work introduces recursive aperture decoded ultrasound imaging (READI) and estimated motion-compensated compounding (EMC2), which look to reduce this sensitivity. READI is a novel decoding and beamforming technique for Hadamard aperture-encoded sequences that produces multiple low-resolution images from subsets of the full sequence. These READI images are less affected by motion and sum to form the complete high-resolution image. EMC2 describes the process of comparing these low-resolution images to estimate the underlying motion, then warping them to align before compounding. This produces a high-resolution image that is resilient to motion. READI with EMC2 applied to the TOBE-based fast orthogonal row-column electronic scanning (FORCES) sequence. It is shown to fully restore images corrupted by probe motion and to recover tissue speckle and boundaries in images of a beating heart phantom. READI low-resolution images by themselves are demonstrated to be a marked improvement over a sparse Hadamard scheme with the same transmit count, and are able to recover blood speckle at a flow rate of 42 cm/s.