For three-level T-type inverter (3LT2I), the unbalanced neutral-point (NP) voltage is required in some photovoltaic (PV) generation systems. Meanwhile, the unbalanced NP voltage easily leads to the fault of power switches. However, the existing fault tolerant control (FTC) strategies are only capable of the balanced NP voltage conditions. In order to simultaneously realize the FTC and unbalanced NP voltage control (UNPVC), a half cycle FTC (HC-FTC) strategy and a whole cycle FTC (WC-FTC) strategy are proposed in this paper. The carrier is modified to avoid using the impossible switching states and realize FTC. Meanwhile, the mathematical models of NP current under both normal and fault conditions are established based on volt-second balance principle, and thereby the zero-sequence component (ZSC) derived by the model can be used to realize the UNPVC whether the switch is fault or not. In addition, the ZSC is selected in detail to improve the NP voltage control ability in HC-FTC. Furthermore, the application range of HC-FTC is obtained and the WC-FTC with wider application range is proposed. The two proposed strategies can be selected according to the requirements. Finally, experimental results validate the effectiveness of the proposed strategies.
21 June 2022 in IEEE Transactions on Transportation Electrification
Neutral-point (NP) voltage and flying capacitor (FC) voltage balance, and power loss reduction are important guarantees for the stable and high-efficiency operation of single-phase five-level active neutral-point clamped (5L-ANPC) converters. However, little reports about capacitor voltage balancing with the power loss reduction have been proposed for single-phase 5L-ANPC converters. In order to obtain the above merits, an improved discontinuous pulsewidth modulation (DPWM) method with capacitor voltage balance and power loss reduction is proposed. First, an optimized common-mode voltage is injected into the modulation waves to decrease the switching loss in each switching period. In particular, the calculation of the injected common-mode voltage is based on the analysis of the deviation of the NP voltage. Hence, a fast-dynamic response of the real-time NP voltage controlling is acquired in the meantime. Besides, in order to balance the FC voltage, the weight factors of NP voltage deviation and FC voltage deviation are compared to generate the selecting signals of redundant switching states. As a result, the capacitor voltage balance and power loss reduction are realized simultaneously. Finally, the simulation and experimental results validate the correctness and feasibility of the proposed DPWM method.
The sinusoidal ripple current charge algorithm enables the battery charger to achieve high power density and high charging efficiency. However, the conventional PI control method is limited by high-frequency variable charging current. In this paper, an integral backstepping control method is proposed to regulate the sinusoidal ripple current, which is modeled and analyzed on a full-bridge DC/DC converter. The backstepping controller is a nonlinear control method that can provide fast output current tracking and good steady-state performance. Moreover, the introduction of the integral term can adaptively compensate the parameter uncertainties and external disturbances, which enhances the robustness and anti-interference ability of the system. The proposed controller achieves fast dynamic response and accurate tracking performance with variable frequency. The simulation verification is carried out, and the comparison results can provide reference for the optimization of the current control strategy of the battery chargers.
1 October 2026 in IEEE Journal of Emerging and Selected Topics in Power Electronics