Xianzhe Pang

Xianzhe Pang

Auto-generated profile, based on publicly available information

Xianzhe Pang

Shandong University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XPXianzhe Pang
Xianzhe Pang
ACAlian Chen
Alian Chen
XLXiaoyan Li
Xiaoyan Li
ZZZhaowen Zhong
Zhaowen Zhong
XLXi Liu
Xi Liu
For three-level T-type inverter (3LT2I), the unbalanced neutral-point (NP) voltage is required in some photovoltaic (PV) generation systems. Meanwhile, the unbalanced NP voltage easily leads to the fault of power switches. However, the existing fault tolerant control (FTC) strategies are only capable of the balanced NP voltage conditions. In order to simultaneously realize the FTC and unbalanced NP voltage control (UNPVC), a half cycle FTC (HC-FTC) strategy and a whole cycle FTC (WC-FTC) strategy are proposed in this paper. The carrier is modified to avoid using the impossible switching states and realize FTC. Meanwhile, the mathematical models of NP current under both normal and fault conditions are established based on volt-second balance principle, and thereby the zero-sequence component (ZSC) derived by the model can be used to realize the UNPVC whether the switch is fault or not. In addition, the ZSC is selected in detail to improve the NP voltage control ability in HC-FTC. Furthermore, the application range of HC-FTC is obtained and the WC-FTC with wider application range is proposed. The two proposed strategies can be selected according to the requirements. Finally, experimental results validate the effectiveness of the proposed strategies.

13 September 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
XPXianzhe Pang
Xianzhe Pang
Tong LiuTong Liu
Tong Liu
YCYanjie Cui
Yanjie Cui
ACAlian Chen
Alian Chen
Three-level T-type inverter (3LT 2 I) plays an essential role in meeting the requirements of high reliability, efficiency, and power density in electrified ships. As these three objectives are mutually interrelated, existing strategies cannot realize them simultaneously. Therefore, a simultaneous current ripple and switching loss reduction strategy for 3LT 2 I under switch fault conditions is proposed in this paper. Based on discontinuous pulse width modulation (DPWM), partial clamping modes are abandoned and the carrier is modified to avoid using the impossible switching states caused by switch fault, which realizes fault tolerant control (FTC) with the switching loss reduction. Then, the new relationship between current ripple and clamping mode under switch fault conditions is quantitatively derived, which is used to select the optimal candidate clamping mode for reducing the current ripple. Moreover, when the neutral-point (NP) voltage exceeds the threshold range, the candidate clamping mode is further selected according to the NP current to balance the NP voltage. By simultaneously realizing FTC, switching loss reduction, current ripple reduction, and NP voltage control, the three objectives mentioned above are realized. Experimental results validate the effectiveness of the proposed strategy.

6 October 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingyue Wang
Mingyue Wang
ACAlian Chen
Alian Chen
YHYaopeng Huang
Yaopeng Huang
XPXianzhe Pang
Xianzhe Pang
CCCheng Cheng
Cheng Cheng
Tong LiuTong Liu
Tong Liu
The Andronov–Hopf virtual oscillator control is a grid-forming control strategy based on instantaneous current feedback, which provides voltage and frequency support in weak grids. However, the unavoidable power coupling and inherent inaccuracies in power tracking control lead to steady-state errors and dynamic oscillations, which severely restrict the power delivery and the grid support capability. Therefore, this article proposes an optimized loop-shaping-based power control (OLPC) strategy to ensure system stability. First, to address the inability of the relative gain array to evaluate feedback dynamics, a closed-loop transfer function array is developed. It explicitly reveals two limitations: failure to achieve power decoupling and amplification of reactive power tracking errors. Subsequently, the objectives of OLPC are formulated in the frequency domain using bandwidth design specifications. Then, the optimal parameters are obtained by reformulating the parameter design problem as a convex optimization problem. Compared to the virtual inductor methods, the OLPC exhibits superior wide-frequency power decoupling, more accurate reactive power tracking, and faster power response. Finally, the theoretical analysis and proposed method are validated through experiments.

1 January 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MWMingyue Wang
Mingyue Wang
ACAlian Chen
Alian Chen
YHYaopeng Huang
Yaopeng Huang
XPXianzhe Pang
Xianzhe Pang
CCCheng Cheng
Cheng Cheng
Tong LiuTong Liu
Tong Liu

10 November 2023
Verified
Conference Paper
Closed access
Xin GaoXin Gao
Xin Gao
XPXianzhe Pang
Xianzhe Pang
ACAlian Chen
Alian Chen
The power router (PR) has been widely used to improve the utilization of renewable energy sources (RES). The intermittent and random nature of RES inevitably increases the fault probability of PR. However, none of the existing methods can realize the fault diagnosis of PR. To address this issue, a novel fault diagnosis method based on transfer learning and gated recurrent unit fully convolutional network (GRU-FCN) is proposed in this paper for internal-diagnosis and external-diagnosis of PR, which includes fault data extraction, fault localization, and fault type classification. First, the current data is extracted from the bus to facilitate fault localization. Subsequently, sensor data from the localized port is utilized for specific fault type classification. Moreover, various fault scenarios of a four-port PR are simulated in MATLAB/Simulink to generate datasets for evaluating the effectiveness of the proposed method. Finally, a comparison between the proposed GRU-FCN model and other neural network models is carried out, which further proves the superiority of the proposed method in the field of fault diagnosis for PR.

5 March 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CCCheng Cheng
Cheng Cheng
ACAlian Chen
Alian Chen
YHYaopeng Huang
Yaopeng Huang
GZGuanguan Zhang
Guanguan Zhang
HZHang Zhang
Hang Zhang
JXJiawei Xing
Jiawei Xing
In addition to the synchronization unit and weak grid, the current control also significantly affects the transient stability of the grid-following inverters (GFIs). Taking into account the dynamic interaction of multiple loops, this article proposes a nonlinear frequency-domain stability criterion, also called absolute stability criterion (ASC), for three-phase GFI (TP-GFI) systems in the gain-limited orthonormal (GLO) synchronization framework. The proposed theoretical criterion, is universally applicable to arbitrary inverter circuit structures and linear current controls, provides an intuitive stability graphical representation in the complex plane, and allows for frequency-sweeping verification without the use of invasive devices. Finally, the proposed theory is further analyzed, validated and discussed through a conventional case.