Ralf Gutjahr

Ralf Gutjahr

Auto-generated profile, based on publicly available information

Ralf Gutjahr

Siemens Healthineers AG, Erlangen Forchheim, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in Investigative Radiology
Verified
Journal Article
Open access
GJGregor Jošt
Gregor Jošt
MMMichael BSc McDermott
Michael BSc McDermott
RGRalf Gutjahr
Ralf Gutjahr
TNTristan Nowak
Tristan Nowak
BSBernhard Schmidt
Bernhard Schmidt
HPHubertus Pietsch
Hubertus Pietsch
The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task. A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role. The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included. Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.

3 June 2022 in Tomography
Verified
Journal Article
Open access
PDF file
FHFlorian Hagen
Florian Hagen
LWLukas Walder
Lukas Walder
JFJan Fritz
Jan Fritz
RGRalf Gutjahr
Ralf Gutjahr
BSBernhard Schmidt
Bernhard Schmidt
MHMarius Horger
Marius Horger
Our aim was to compare the image quality and patient dose of contrast-enhanced oncologic chest-CT of a first-generation photon-counting detector (PCD-CT) and a second-generation dual-source dual-energy CT (DSCT). For this reason, one hundred consecutive oncologic patients (63 male, 65 ± 11 years, BMI: 16–42 kg/m2) were prospectively enrolled and evaluated. Clinically indicated contrast-enhanced chest-CT were obtained with PCD-CT and compared to previously obtained chest-DSCT in the same individuals. The median time interval between the scans was three months. The same contrast media protocol was used for both scans. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120 kVp. DSCT was performed using 100 kV for Tube A and 140 kV for Tube B. “T3D” PCD-CT images were evaluated, which emulate conventional 120 keV polychromatic images. For DSCT, the convolution algorithm was set at I31f with class 1 iterative reconstruction, whereas comparable Br40 kernel and iterative reconstruction strengths (Q1 and Q3) were applied for PCD-CT. Two radiologists assessed image quality using a five-point Likert scale and performed measurements of vessels and lung parenchyma for signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and in the case of pulmonary metastases tumor-to-lung parenchyma contrast ratio. PCD-CT CNRvessel was significantly higher than DSCT CNRvessel (all, p < 0.05). Readers rated image contrast of mediastinum, vessels, and lung parenchyma significantly higher in PCD-CT than DSCT images (p < 0.001). Q3 PCD-CT CNRlung_parenchyma was significantly higher than DSCT CNRlung_parenchyma and Q1 PCD-CT CNRlung_parenchyma (p < 0.01). The tumor-to-lung parenchyma contrast ratio was significantly higher on PCD-CT than DSCT images (0.08 ± 0.04 vs. 0.03 ± 0.02, p < 0.001). CTDI, DLP, SSDE mean values for PCD-CT and DSCT were 4.17 ± 1.29 mGy vs. 7.21 ± 0.49 mGy, 151.01 ± 48.56 mGy * cm vs. 288.64 ± 31.17 mGy * cm and 4.23 ± 0.97 vs. 7.48 ± 1.09, respectively. PCD-CT enables oncologic chest-CT with a significantly reduced dose while maintaining image quality similar to a second-generation DSCT for comparable protocol settings.

1 May 2019 in Radiology
Verified
Journal Article
Closed access
RHRicarda Hinzpeter
Ricarda Hinzpeter
MEMatthias Eberhard
Matthias Eberhard
RGRalf Gutjahr
Ralf Gutjahr
KRKelly Reeve
Kelly Reeve
TPThomas Pfammatter
Thomas Pfammatter
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
An individualized trigger delay improves contrast opacification in CT angiography of the aorta, yielding a higher and more constant attenuation as well as an improved subjective image quality. BackgroundOptimal timing of the CT scan relative to the contrast media bolus remains a challenging task given the shorter scan durations of modern CT scanners, as well as interpatient variability.PurposeTo compare contrast opacification in CT angiography of the aorta between a cohort with fixed trigger delay and a cohort with patient-specific individualized trigger delay for contrast media timing with bolus tracking.Materials and MethodsIn this prospective study (January–August 2018), CT angiography of the thoracoabdominal aorta with bolus tracking was performed in two different study cohorts: one with a fixed trigger delay of 4 seconds (fixed cohort) and one with a patient-specific trigger delay (individualized cohort). All CT and contrast media protocol parameters were kept identical among cohorts. Objective image quality was evaluated by one reader; two readers assessed subjective image quality. Student t test was used to test for differences in mean attenuation; the Wilcoxon-Mann-Whitney test was used...

10 March 2025 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Open access
CKConstantin Kleinbeck
Constantin Kleinbeck
HSHannah Schieber
Hannah Schieber
KEKlaus Engel
Klaus Engel
RGRalf Gutjahr
Ralf Gutjahr
DRDaniel Roth
Daniel Roth
In medical image visualization, path tracing of volumetric medical data like computed tomography (CT) scans produces lifelike three-dimensional visualizations. Immersive virtual reality (VR) displays can further enhance the understanding of complex anatomies. Going beyond the diagnostic quality of traditional 2D slices, they enable interactive 3D evaluation of anatomies, supporting medical education and planning. Rendering high-quality visualizations in real-time, however, is computationally intensive and impractical for compute-constrained devices like mobile headsets. We propose a novel approach utilizing Gaussian Splatting (GS) to create an efficient but static intermediate representation of CT scans. We introduce a layered GS representation, incrementally including different anatomical structures while minimizing overlap and extending the GS training to remove inactive Gaussians. We further compress the created model with clustering across layers. Our approach achieves interactive frame rates while preserving anatomical structures, with quality adjustable to the target hardware. Compared to standard GS, our representation retains some of the explorative qualities initially enabled by immersive path tracing. Selective activation and clipping of layers are possible at rendering time, adding a degree of interactivity to otherwise static GS models. This could enable scenarios where high computational demands would otherwise prohibit using path-traced medical volumes.

1 October 2018 in Academic Radiology
Verified
Journal Article
Closed access
AFAndrea Ferrero
Andrea Ferrero
RGRalf Gutjahr
Ralf Gutjahr
AHAhmed F. Halaweish
Ahmed F. Halaweish
SLShuai Leng
Shuai Leng
CMCynthia H. McCollough
Cynthia H. McCollough

15 May 2024 in Investigative Radiology
Verified
Journal Article
Open access
MMMichael C. BSc McDermott
Michael C. BSc McDermott
TSThomas Sartoretti
Thomas Sartoretti
LSLion Msc Stammen
Lion Msc Stammen
BMBibi Martens
Bibi Martens
GJGregor Jošt
Gregor Jošt
JWJoachim E. Wildberger
Joachim E. Wildberger
Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. Materials and Methods: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. Results: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R 2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. Conclusions: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.