1 June 2022 in Review of Scientific Instruments
A thrust stand is developed for testing micro-Newton level thrusters on the ground. The stand is composed of a compound pendulum that is symmetrically suspended by two thin beryllium copper strips, and it is precisely calibrated by gravity. The stiffness of the stand can be adjusted in 3 orders of magnitude by a counterweight. When the stiffness is larger than 1 Nm/rad, the stand demonstrates a fast response to thrust. The measured range of the stand reaches 1000 μN, and the noise is less than 0.1 μN/ within 1 mHz–1 Hz. To calibrate the resolution of the stand, an electrostatic force is applied to the stand with an actuator. The equivalent thrust is determined to be 0.09 μN with a standard uncertainty of 0.02 μN. Using the stand, a micro-Newton colloid thruster is tested. The output of the colloid thruster changes with the applied voltage as 0.015(1) μN/V. When changing the voltage by 50 V, the change in thrust is measured to be 0.7 μN with a standard uncertainty of 0.1 μN.
1 January 2023 in Review of Scientific Instruments
A decoupling method is proposed for micro-Newton thrust measurement with a torsion pendulum. The basic approach is to reduce the influences introduced by the propellant tube and wires of the thruster. A hollow aluminum tube is used to hang the torsion pendulum and is also chosen as the transport pipe for the propellant of the thruster. The electric control box of the thruster is mounted on the pendulum body, which is powered by an externally installed power supply through a liquid metal conductive unit. The control of the electric control box is performed through wireless transmission. With this design, the influences of the propellant tube and connection wires between the torsion pendulum and the outside device are reduced and the stability of the torsion spring constant of the system can be improved. The use of the liquid metal conductive unit reduces the coupling between the wires and the measurement system. The feasibility of the wireless transmission is analyzed. The error sources during the thrust measurement are analyzed, and the expected three σ uncertainty of the thrust is N for the measurement of the cold gas thruster. The scheme provides a thrust measurement with higher precision and stability.
18 February 2020 in Physical Review D
In the recent CODATA-2014 adjustment, the values obtained by different groups are not in good agreement with each other within respective uncertainties, which may be attributed to the possible unknown or incorrectly evaluated systematic errors in different methods. This paper proposes a scheme to measure with two independent methods. The first method is the extraction of the value from the fundamental periods of the torsion pendulum, with the source masses at two positions; the other one determines the value on the basis of the amplitude of the third-order harmonic component of the torsion pendulum. Both methods are performed with the same setup by using the large-amplitude torsion pendulum. Through theoretical derivation and simulation, the uncertainties of the values obtained by the two methods are both expected to be within 20 ppm. By comparing the values from the two methods, we can explore the potential systematic errors in the measurement.
1 September 2023 in Review of Scientific Instruments
In the space-borne gravitational wave detection TianQin project, the locking and releasing of test mass is one of the key technologies. The test mass will be locked during the spacecraft launch and then released to free fall for the science phase. The residual release impulse is required to be on the order of magnitude of 10−5 kg m/s, which allows us to capture the test mass by the force authority of the capacity control. In this paper, the release impulse of the aluminum test mass is measured with a compound pendulum for the TianQin project. The test mass is locked by two tips from opposite positions, and the release impulse is obtained from the oscillation of the pendulum. When the aluminum test mass is locked and released by the stainless steel and aluminum tips, the release impulses and their uncertainties are on the order of magnitude of 10−5and 10−7 kg m/s, respectively. This provides a feasible measurement scheme for the impulse testing in the TianQin project.
29 October 2024 in Physical Review Applied
30 April 2025 in Physical Review D