1 September 2023 in Review of Scientific Instruments
In the space-borne gravitational wave detection TianQin project, the locking and releasing of test mass is one of the key technologies. The test mass will be locked during the spacecraft launch and then released to free fall for the science phase. The residual release impulse is required to be on the order of magnitude of 10−5 kg m/s, which allows us to capture the test mass by the force authority of the capacity control. In this paper, the release impulse of the aluminum test mass is measured with a compound pendulum for the TianQin project. The test mass is locked by two tips from opposite positions, and the release impulse is obtained from the oscillation of the pendulum. When the aluminum test mass is locked and released by the stainless steel and aluminum tips, the release impulses and their uncertainties are on the order of magnitude of 10−5and 10−7 kg m/s, respectively. This provides a feasible measurement scheme for the impulse testing in the TianQin project.
29 October 2024 in Physical Review Applied
30 April 2025 in Physical Review D
28 September 2026 in Measurement Science and Technology
A two-stage pendulum system, comprising a lower torsion pendulum and an upper torsion pendulum, is widely employed in gravitational experiments. While prior research has focused primarily on the vibration isolation capability of the magnetic damper, this study investigates the dissipation coupling mechanism between the upper and lower torsion pendulums through theoretical analysis and experimental validation. The dynamic model of the two-stage pendulum system is analyzed, and expressions for the quality factor (hereafter denoted as value) of each stage are derived. An experimental apparatus is designed and constructed to enable modulation of the value of the upper torsion pendulum and then measure the response of the lower torsion pendulum. Results indicate that when the horizontal magnetic field at the center of the upper torsion pendulum is increased from 1.37 to 20.63 mT, the value of the upper torsion pendulum decreases from 701 to 7, which leads to a reduction in the value of the lower torsion pendulum—from 1.6 10 to 9.0 10 . In gravitational experiments with a silica fiber, after using the magnetic damper, the value of the lower torsion pendulum can be reduced by approximately half, which results in an increase in thermal noise. This work offers valuable insights into the dissipation coupling mechanism of a two-stage pendulum system and aids in assessing noise sources in precision measurements.