Christian Vogt

Christian Vogt

Auto-generated profile, based on publicly available information

Christian Vogt

Center for Project-Based Learning, ETH Zrich, Zrich, Switzerland

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TMTobias Margiani
Tobias Margiani
SCSilvano Cortesi
Silvano Cortesi
MKMilena Keller
Milena Keller
CVChristian Vogt
Christian Vogt
TPTommaso Polonelli
Tommaso Polonelli
Michele MagnoMichele Magno
Michele Magno
Accurate and low-power indoor localization is becoming more and more of a necessity to empower novel consumer and industrial applications. In this field, the most promising technology is based on Ultra-Wideband (UWB) modulation; however, current UWB positioning systems do not reach centimeter accuracy in general deployments due to multi-path and non-isotropic antennas, still necessitating several fixed anchors to estimate an object’s position in space. This paper presents an in-depth study and assessment of Angle of Arrival (AoA) UWB measurements using a compact, low-power solution integrating a novel commercial module with Phase Difference of Arrival (PDoA) estimation as integrated feature. Results demonstrate the possibility of reaching centimeter distance precision and 2.4° average angular accuracy in many operative conditions, e.g., in a 90° range around the center. Moreover, integrating the channel impulse response, the phase differential of arrival, and the point-to-point distance, an error correction model is discussed to compensate for reflections, multi-paths, and front-back ambiguity.

21 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
BSBenjamin Sporrer
Benjamin Sporrer
LWLianbo Wu
Lianbo Wu
LBLuca Bettini
Luca Bettini
CVChristian Vogt
Christian Vogt
JRJonas Reber
Jonas Reber
QHQiuting Huang
Qiuting Huang
Magnetic resonance imaging (MRI) is among the most important medical imaging modalities. Coil arrays and receivers with high channel counts (16 and more) have to be deployed to obtain the image quality and acquisition speed required by modern clinical protocols. In this paper, we report the theoretical analysis, the system-level design, and the circuit implementation of the first receiver IC (RXIC) for clinical MRI fully integrated in a modern CMOS technology. The dual-channel RXIC sits directly on the sensor coil, thus eliminating any RF cable otherwise required to transport the information out of the magnetic field. The first stage LNA was implemented using a noise-canceling architecture providing a highly reflective input used to decouple the individual channels of the array. Digitization is performed directly on-chip at base-band by means of a delta-sigma modulator, allowing the subsequent optical transmission of data. The presented receiver, implemented in a $\mathbf {{130}\,{nm}}$ CMOS technology, is compatible with MRI scanners up to $\mathbf {{10.5}\,{T}}$. It reaches sub-$\mathbf {{1}\,{dB}}$ noise figure for $\mathbf {{3\!-\! 7}\,{T}}$ MRI units and features a dynamic range up to $\mathbf {{81.9}\,{dB}}$ at a power consumption below $\mathbf {{240}\,{mW}}$ per channel, with an area occupation of $\mathbf {{22}\,{mm^2}}$. Mounted on a small-sized printed circuit board (PCB), the receiver IC has been employed in a commercial MRI scanner to acquire in-vivo images matching the quality of traditional systems, demonstrating the first step toward multichannel wearable MRI array coils.

11 October 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AMAndreas Mehmann
Andreas Mehmann
MVMatija Varga
Matija Varga
CVChristian Vogt
Christian Vogt
APAndreas Port
Andreas Port
JRJonas Reber
Jonas Reber
GTGerhard Tröster
Gerhard Tröster
The eGaIn coil on neoprene demonstrated in this paper presents a stretchable radio frequency receive coil for MRI. The coil with dimensions 86mm × 70mm is tuned to resonate at 128MHz for 3T MRI. We investigate the effect of stretching (up to 40% strain) and bending (50mm radius of curvature) of the coil on the coil's resistance and resonance frequency. Measurements and simulations show a decrease in resonance frequency of 2.5MHz per 10% strain. The higher resistivity of liquid metal compared to copper reduces the SNR of MRI scans by 2.1dB; therefore a trade-off between flexibility and performance remains. Nevertheless, we have successfully performed MRI scans with the liquid metal coil.

10 March 2023 in Computers
Verified
Journal Article
Open access
PDF file
SCSilvano Cortesi
Silvano Cortesi
CVChristian Vogt
Christian Vogt
Michele MagnoMichele Magno
Michele Magno
IPS is a crucial technology that enables medical staff and hospital management to accurately locate and track persons or assets inside medical buildings. Among other technologies, readily available BLE can be exploited to achieve an energy-efficient and low-cost solution. This work presents the design, implementation and comparison of a RSSI-based and a MCPD-based indoor localization system. The implementation is based on a lightweight wkNN algorithm that processes RSSI and MCPD distance data from connection-less BLE Beacons. The designed hardware and firmware are implemented around the state-of-the-art SoC for BLE, the nRF5340 from Nordic Semiconductor. Experimental evaluation with real-time data processing has been evaluated and presented in a 7.3 m × 8.9 m room with furniture and six beacon nodes. The experimental results on randomly chosen validation points within the room show an average error of only 0.50 m for the MCPD approach, whereas the RSSI approach achieved an error of 1.39 m.

2 June 2017 in Technologies
Verified
Journal Article
Open access
PDF file
Niko MünzenriederNiko Münzenrieder
Niko Münzenrieder
CVChristian Vogt
Christian Vogt
LPLuisa Petti
Luisa Petti
GSGiovanni A. Salvatore
Giovanni A. Salvatore
GCGiuseppe Cantarella
Giuseppe Cantarella
GTGerhard Tröster
Gerhard Tröster
Smart textiles promise to have a significant impact on future wearable devices. Among the different approaches to combine electronic functionality and fabrics, the fabrication of active fibers results in the most unobtrusive integration and optimal compatibility between electronics and textile manufacturing equipment. The fabrication of electronic devices, in particular transistors on heavily curved, temperature sensitive, and rough textiles fibers is not easily achievable using standard clean room technologies. Hence, we evaluated different fabrication techniques and multiple fibers made from polymers, cotton, metal and glass exhibiting diameters down to 125 μm. The benchmarked techniques include the direct fabrication of thin-film structures using a low temperature shadow mask process, and the transfer of thin-film transistors (TFTs) fabricated on a thin (≈1 μm) flexible polymer membrane. Both approaches enable the fabrication of working devices, in particular the transfer method results in fully functional transistor fibers, with an on-off current ratio > 10 7 , a threshold voltage of ≈0.8 V , and a field effect mobility exceeding 7 c m 2 V − 1 s − 1 . Finally, the most promising fabrication approach is used to integrate a commercial nylon fiber functionalized with InGaZnO TFTs into a woven textile.

26 November 1993 in British Journal of Urology
Verified
Journal Article
Closed access
PDF file
MSM. H. Sohn
M. H. Sohn
CVC. Vogt
C. Vogt
GHG. Heinen
G. Heinen
MEM. Erkens
M. Erkens
NNN. Nordmeyer
N. Nordmeyer
GJG. Jakse
G. Jakse