Ana Sainz-García

Ana Sainz-García

Auto-generated profile, based on publicly available information

Ana Sainz-García

Department of Mechanical Engineering. University of La Rioja, Logroño, Spain

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Innovative Food Science & Emerging Technologies
Verified
Journal Article
Closed access
IMIgnacio Muro-Fraguas
Ignacio Muro-Fraguas
ASAna Sainz-García
Ana Sainz-García
PGPaula Fernández Gómez
Paula Fernández Gómez
MLMaría López
María López
RMRodolfo Múgica-Vidal
Rodolfo Múgica-Vidal
FAFernando Alba-Elías
Fernando Alba-Elías

1 October 2020 in Surface and Coatings Technology
Verified
Journal Article
Closed access
IMIgnacio Muro-Fraguas
Ignacio Muro-Fraguas
ASAna Sainz-García
Ana Sainz-García
MLMaria Lopez
Maria Lopez
BRBeatriz Rojo-Bezares
Beatriz Rojo-Bezares
RMRodolfo Múgica-Vidal
Rodolfo Múgica-Vidal
FAFernando Alba-Elías
Fernando Alba-Elías

1 February 2022 in Food Research International
Verified
Journal Article
Closed access
PFPaula Fernández-Gómez
Paula Fernández-Gómez
IMIgnacio Muro-Fraguas
Ignacio Muro-Fraguas
RMRodolfo Múgica-Vidal
Rodolfo Múgica-Vidal
ASAna Sainz-García
Ana Sainz-García
ESElisa Sainz-García
Elisa Sainz-García
FAFernando Alba-Elías
Fernando Alba-Elías

20 October 2023 in Plasma Chemistry and Plasma Processing
Verified
Journal Article
Open access
PDF file
CMCaterina Maccaferri
Caterina Maccaferri
ASAna Sainz-García
Ana Sainz-García
FCfilippo capelli
filippo capelli
Matteo GherardiMatteo Gherardi
Matteo Gherardi
FAFernando Alba-Elías
Fernando Alba-Elías
RLRomolo Laurita
Romolo Laurita
The food industry, as a consequence of globalization and in particular with the outbreak of the COVID-19 pandemic, is calling for additional measures to reduce the risks of contamination throughout the steps of the food chain. Several methods are used to avoid this problem, such as hot water or chemical procedures. However, they have some disadvantages like high economic costs or the fact that they are not eco-friendly technologies. For those reasons, novel strategies are being sought in order to substitute or work in synergy with conventional decontamination systems. Cold atmospheric pressure plasma (CAP) can be produced by many various sources for a wide range of different applications, including decontamination. In this study, a Large-Area Surface Dielectric Barrier Discharge plasma source has been used with the aim of inactivating Staphylococcus epidermidis inoculated on polypropylene food packaging samples inside a treatment chamber. Moreover, electrical and chemical analysis of the plasma source has been carried out, as well as temperature measurements. A homogenous distribution of the reactive species inside the treatment chamber was suggested, achieving almost 2 log of bacteria reduction for every plasma treatment. Finally, it was suggested that the inactivation rates reached were not caused by the thermal effect. Thus, it is strongly believed that CAP could be an eco-friendly, cheap, and sustainable technology for food packaging and food tools decontamination.

18 November 2021 in Foods
Verified
Journal Article
Open access
PDF file
IMIgnacio Muro-Fraguas
Ignacio Muro-Fraguas
PFPaula Fernández-Gómez
Paula Fernández-Gómez
RMRodolfo Múgica-Vidal
Rodolfo Múgica-Vidal
ASAna Sainz-García
Ana Sainz-García
ESElisa Sainz-García
Elisa Sainz-García
FAFernando Alba-Elías
Fernando Alba-Elías
Biofilm formation on food-contact surfaces is a matter of major concern causing food safety and spoilage issues to this sector. The aim of this study was to assess the durability of the anti-biofilm capacity of a plasma-polymerized coating composed of a base coating of (3-aminopropyl)triethoxysilane (APTES) and a functional coating of acrylic acid (AcAc). Coated and uncoated AISI 316 stainless steel (SS) plates were subjected to five sanitization cycles with sodium hypochlorite (0.05%) and peracetic acid (0.5%). The effectiveness of the coating for the inhibition of multi-strain Listeria monocytogenes biofilm formation was confirmed using a three-strain cocktail, which was grown on the SS plates at 12 °C for 6 days. Compared to the uncoated SS, relative biofilm productions of 14.6% on the non-sanitized coating, 27.9% on the coating after sanitization with sodium hypochlorite, and 82.3% on the coating after sanitization with peracetic acid were obtained. Morphological and physicochemical characterization of the coatings suggested that the greater anti-biofilm effectiveness after sanitization with sodium hypochlorite was due to the high pH of this solution, which caused a deprotonation of the carboxylic acid groups of the functional coating. This fact conferred it a strong hydrophilicity and negatively charged its surface, which was favorable for preventing bacterial attachment and biofilm formation.

7 November 2022 in Plasma Processes and Polymers
Verified
Journal Article
Open access
IMIgnacio Muro‐Fraguas
Ignacio Muro‐Fraguas
ASAna Sainz‐García
Ana Sainz‐García
RMRodolfo Múgica-Vidal
Rodolfo Múgica-Vidal
ESElisa Sainz-García
Elisa Sainz-García
AGAna González‐Marcos
Ana González‐Marcos
FAFernando Alba-Elías
Fernando Alba-Elías
The global needle market is growing due to an increase in the geriatric population, chronic diseases, and the high demand for vaccines. High insertion forces cause unpleasant effects on patients, needle deformation, and tissue displacement, affecting the accuracy of the methods. To reduce insertion forces, atmospheric‐pressure plasma‐polymerized coatings were deposited on spinal needles. The influence of liquid precursor, plasma power, precursor gas flow, and treatment time has been analyzed. To avoid plasma‐polymerized coatings detached after the injection test, it is necessary to apply a precursor that not only has antifriction molecules (siloxane) but also has particles that promote the durability of the coatings (amines). N1‐(3‐trimethoxysilylpropyl)diethylenetriamine (TRIAP) was the most effective, reducing insertion–extraction forces regarding noncoated spinal needles, by 75% and 50%, respectively.