1 April 2025 in Review of Scientific Instruments
We have developed a two-color CO2 laser interferometer in JT-60SA, which features a long transmission line and a long-time stabilization system. We inject two laser beams with an optimized beam size into the plasma of JT-60SA. A newly developed beam axis stabilizing system stabilizes the laser beam line to the plasma, which constitutes one fourth of the total line length of 214 m, for more than 11 hours, ensuring no beam line loss during the integrated commissioning phase of JT-60SA. It is possible to measure the line-integrated electron densities of JT-60SA plasmas with a resolution of 2 × 1019 m−2. The typical NeL = 1.4 × 1020 m−2. Experimental evidence also demonstrates the challenge of compensating for line-integrated electron density errors, even with a two-color interferometer.
1 August 2024 in Review of Scientific Instruments
A preparatory study is underway to investigate the feasibility study of high-energetic, non-thermal electron distribution function measurements using a vertical-viewing electron cyclotron emission (ECE) diagnostic on JT-60SA. The system is designed to detect broad ECE spectra (70–260 GHz) due to the second, third, and fourth harmonics using a focusing optics system with four quasi-optical mirrors in the upper port of JT-60SA. A Gaussian beam optics design is performed in vacuum, and ray tracing calculations are performed in plasma using the TRAVIS code to investigate density characteristics. A ceramic viewing dump is also designed to reduce the effects of multiple reflections from the opposing vacuum vessel surface.
1 October 2025 in Journal of Instrumentation
JT-60SA is currently the world's largest superconducting tokamak. It accelerates the realization of fusion energy by supporting ITER exploitation and complementing it in addressing key physics and engineering issues for DEMO reactors. The main targets of JT-60SA are breakeven-equivalent high-temperature deuterium plasmas and high- β steady-state plasmas. To achieve these goals, laser-aided diagnostics with high spatial resolution are essential for detailed physics studies. In Operation Phase 1, a tangential single-chord two-color CO 2 laser interferometer was installed. The data acquisition and processing system featured fringe-jump detection and real-time processing, enabling density feedback control. In the upcoming operational phases, a CO 2 laser polarimeter and Thomson scattering diagnostics will be implemented in Operation Phase 2, followed by the installation of phase-contrast imaging in Operation Phase 3. This paper summarizes the measurement results from the first operational phase and outlines the design and current status of the other three diagnostics.
1 April 2025 in Review of Scientific Instruments
We have developed a two-color CO2 laser interferometer in JT-60SA, which features a long transmission line and a long-time stabilization system. We inject two laser beams with an optimized beam size into the plasma of JT-60SA. A newly developed beam axis stabilizing system stabilizes the laser beam line to the plasma, which constitutes one fourth of the total line length of 214 m, for more than 11 hours, ensuring no beam line loss during the integrated commissioning phase of JT-60SA. It is possible to measure the line-integrated electron densities of JT-60SA plasmas with a resolution of 2 × 1019 m−2. The typical NeL = 1.4 × 1020 m−2. Experimental evidence also demonstrates the challenge of compensating for line-integrated electron density errors, even with a two-color interferometer.