1 July 2024 in Review of Scientific Instruments
A real-time processing system for the two-color CO2 laser interferometer on the JT-60SA has been developed for density feedback control. The system has a novel feature that can detect fringe jumps due to off-normal events, such as loss detection due to displacement of the beam axis and changes in the laser wavelengths. Because a phase change due to the JT-60SA plasma is smaller than π/2, corresponding to the line-integral electron density NL of ∼6×1019 m−2 in a short interval of 500 ns, the threshold of the fringe jump detection is decided to be π/2. Hence, off-normal events can be detected from a fringe jump, leading to the abort of the real-time feedback control. In the density feedback control of the JT-60SA plasma, the system is employed as a density monitor, with NL being successfully controlled at 16.8% ± 6.6% lower than the reference.
1 April 2025 in Review of Scientific Instruments
We have developed a two-color CO2 laser interferometer in JT-60SA, which features a long transmission line and a long-time stabilization system. We inject two laser beams with an optimized beam size into the plasma of JT-60SA. A newly developed beam axis stabilizing system stabilizes the laser beam line to the plasma, which constitutes one fourth of the total line length of 214 m, for more than 11 hours, ensuring no beam line loss during the integrated commissioning phase of JT-60SA. It is possible to measure the line-integrated electron densities of JT-60SA plasmas with a resolution of 2 × 1019 m−2. The typical NeL = 1.4 × 1020 m−2. Experimental evidence also demonstrates the challenge of compensating for line-integrated electron density errors, even with a two-color interferometer.
1 October 2025 in Journal of Instrumentation
JT-60SA is currently the world's largest superconducting tokamak. It accelerates the realization of fusion energy by supporting ITER exploitation and complementing it in addressing key physics and engineering issues for DEMO reactors. The main targets of JT-60SA are breakeven-equivalent high-temperature deuterium plasmas and high- β steady-state plasmas. To achieve these goals, laser-aided diagnostics with high spatial resolution are essential for detailed physics studies. In Operation Phase 1, a tangential single-chord two-color CO 2 laser interferometer was installed. The data acquisition and processing system featured fringe-jump detection and real-time processing, enabling density feedback control. In the upcoming operational phases, a CO 2 laser polarimeter and Thomson scattering diagnostics will be implemented in Operation Phase 2, followed by the installation of phase-contrast imaging in Operation Phase 3. This paper summarizes the measurement results from the first operational phase and outlines the design and current status of the other three diagnostics.
1 April 2025 in Review of Scientific Instruments
We have developed a two-color CO2 laser interferometer in JT-60SA, which features a long transmission line and a long-time stabilization system. We inject two laser beams with an optimized beam size into the plasma of JT-60SA. A newly developed beam axis stabilizing system stabilizes the laser beam line to the plasma, which constitutes one fourth of the total line length of 214 m, for more than 11 hours, ensuring no beam line loss during the integrated commissioning phase of JT-60SA. It is possible to measure the line-integrated electron densities of JT-60SA plasmas with a resolution of 2 × 1019 m−2. The typical NeL = 1.4 × 1020 m−2. Experimental evidence also demonstrates the challenge of compensating for line-integrated electron density errors, even with a two-color interferometer.
1 November 2026 in Review of Scientific Instruments
Density profile reconstruction and fringe-jump correction using a toroidal interferometer and polarimeter with a limited number of chords have been developed to reduce the number of diagnostic ports in future devices. The density profile reconstruction method exploits the fact that the line of sight through the high-field side can be treated as two effective lines of sight (LOSs) due to the magnetic field geometry. The reconstruction is based on Gaussian process regression and Markov chain Monte Carlo sampling. For a single LOS without significant gradient variation, the coefficient of determination R2 exceeds 0.9, where a value closer to unity indicates better reproduction of the profile. For density profiles with steep gradient variation, although three LOSs are required, the reconstruction accuracy surpasses that of interferometry with the same number of chords. A fringe-jump correction method exploits the fact that the temporal evolution of the density is preserved even when the absolute density from the interferometer is lost. Assuming a linear density change, the estimated line-integrated density improves from 88.9% to 92.1% of the true value compared with the polarimeter-only reconstruction. If the interferometer error is ten times smaller than the polarimeter error, the improvement reaches 96.6%.