O(On The Behalf Of The Alliance For Breast Cancer Screening In Korea (Abcs-K)
On The Behalf Of The Alliance For Breast Cancer Screening In Korea (Abcs-K)
+5
Purpose: The purpose of this study was to record and evaluate interobserver agreement as quality control for the modified categorization of screening breast ultrasound developed by the Alliance for Breast Cancer Screening in Korea (ABCS-K) for the Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial. Methods: Eight breast radiologists with 4-16 years of experience participated in 2 rounds of quality control testing for the MUST-BE trial. Two investigators randomly selected 125 and 100 cases of breast lesions with different ratios of malignant and benign lesions. Two versions of the modified categorization were tested. The initially modified classification was developed after the first quality control workshop, and the re-modified classification was developed after the second workshop. The re-modified categorization established by ABCS-K added size criteria and the anterior-posterior ratio compared with the initially modified classification. After a brief lecture on the modified categorization system prior to each quality control test, the eight radiologists independently categorized the lesions using the modified categorization. Interobserver agreement was measured using kappa statistics. Results: The overall kappa values for the modified categorizations indicated moderate to substantial degrees of agreement (initially modified categorization and re-modified categorization: kappa=0.52 and kappa=0.63, respectively). The kappa values for the subcategories of category 4 were 0.37 (95% confidence interval [CI], 0.24 to 0.52) and 0.39 (95% CI, 0.31 to 0.49), respectively. The overall kappa values for both the initially modified categorization and the re-modified categorization indicated a substantial degree of agreement when dichotomizing the interpretation as benign or suspicious. Conclusion: The preliminary results demonstrated acceptable interobserver agreement for the modified categorization.
This study aimed to evaluate the ultrasonographic findings for various types of vascular closure devices (VCDs) immediately after the angiographic procedure and at 6-month follow-up. We included 18 VCDs including Angio-Seal (n=4), FemoSeal (n=8), ExoSeal (n=3), Perclose (n=2), and StarClose (n=1) in this study. Four patients were implanted with 2 VCDs at the each side of bilateral femoral arteries, while the remaining 8 patients were inserted 1 VCD at the right femoral artery. Ultrasonography was performed within 10 days and at approximately 6 months after the angiographic procedure. Ultrasonographic morphology of the attached VCD and its relationship with the arterial wall were analyzed. Initial ultrasonography revealed the attached VCD as the relevant unique structure with successful deployment and hemostasis. Follow-up ultrasonography demonstrated partial absorption of hemostatic materials in cases of Angio-Seal (n=3), FemoSeal (n=5), and ExoSeal (n=3), changes in the soft tissue surrounding the femoral artery in case of Angio-Seal (n=1), arterial intimal hyperplasia in cases of FemoSeal (n=3), and no gross changes as compared with the initial ultrasonographic findings in cases of Perclose (n=2) and StarClose (n=1). Initial ultrasonographic evaluation reflected the unique structure of each VCD, with most of them being easily distinguishable. Follow-up ultrasonography revealed various changes in the affected vessels.
1 January 2026 in Radiology: Artificial Intelligence
Artificial intelligence–based computer-assisted diagnosis (AI-CAD) identified some breast cancers missed by radiologists but failed to detect others recalled by radiologists. Careful implementation and strategic interpretation of AI-CAD are essential in mammographic screening.