Miki Lee

Miki Lee

Auto-generated profile, based on publicly available information

Miki Lee

Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GLGaoming Li
Gaoming Li
XDXiyu Duan
Xiyu Duan
MLMiki Lee
Miki Lee
MBMayur Birla
Mayur Birla
JCJing Chen
Jing Chen
HLHaijun Li
Haijun Li
Point-of-care medical diagnosis demands immediate feedback on tissue pathology. Confocal endomicroscopy can provide real-time in vivo images with histology-like features. The working channel in medical endoscopes are becoming smaller in dimension. Microsystems methods can produce tiny mechanical scanners. We demonstrate a flexible fiber instrument for in vivo imaging as an endoscope accessory. The optical path is folded on-axis to reduce length while allowing the beam to expand and achieve a numerical aperture of 0.41. A high-speed parametric resonance mirror produces large deflection angles > 13°, and is mounted on a 2 mm diameter chip designed with clamp structures for reduced space. A compact lens assembly provides diffraction-limited lateral and axial resolution of 1.5 and 12 μm , respectively. A working distance of 50 μm and field-of-view of 350 μm x 350 μm are achieved. Miniature apparatus is fabricated to assemble and align the scanhead components. The optics and scanner are packaged in a distal tip with 2.4 mm diameter and 10 mm rigid length. These dimensions allow the endomicroscope to pass forward easily through the 2.8 mm diameter working channel in medical endoscopes commonly used in clinical practice. Fluorescence images are collected in vivo at 10 frames per second in the colon of genetically-engineered mice that spontaneously develop adenomas. A FITC-labeled peptide heterodimer is administered intravenously to provide specific contrast. Sub-cellular structures are visualized to distinguish pre-malignant from normal mucosa. These results demonstrate use of microsystems methods to produce an ultra-compact instrument with sufficiently small dimensions for broad use.

25 October 2021 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
JCJing Chen
Jing Chen
VNVan Phuc Nguyen
Van Phuc Nguyen
SJSangeeta Jaiswal
Sangeeta Jaiswal
XKXiaoyu Kang
Xiaoyu Kang
MLMiki Lee
Miki Lee
TWThomas Wang
Thomas Wang
The large size of nanoparticles prevents rapid extravasation from blood vessels and diffusion into tumors. Multimodal imaging uses the physical properties of one modality to validate the results of another. We aim to demonstrate the use of a targeted thin layer-protected ultra-small gold nanoparticles (Au-NPs) to detect cancer in vivo using multimodal imaging with photoacoustic and computed tomography (CT). The thin layer was produced using a mixed thiol-containing short ligands, including MUA, CVVVT-ol, and HS-(CH2)11-PEG4-OH. The gold nanoparticle was labeled with a heterobivalent (HB) peptide ligand that targets overexpression of epidermal growth factor receptors (EGFR) and ErbB2, hereafter HB-Au-NPs. A human xenograft model of esophageal cancer was used for imaging. HB-Au-NPs show spherical morphology, a core diameter of 4.47 ± 0.8 nm on transmission electron microscopy, and a hydrodynamic diameter of 6.41 ± 0.73 nm on dynamic light scattering. Uptake of HB-Au-NPs was observed only in cancer cells that overexpressed EGFR and ErbB2 using photoacoustic microscopy. Photoacoustic images of tumors in vivo showed peak HB-Au-NPs uptake at 8 h post-injection with systemic clearance by ~48 h. Whole-body images using CT validated specific tumor uptake of HB-Au-NPs in vivo. HB-Au-NPs showed good stability and biocompatibility with fast clearance and contrast-enhancing capability for both photoacoustic and CT imaging. A targeted thin layer-protected gold nanoprobe represents a new platform for molecular imaging and shows promise for early detection and staging of cancer.

27 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MLMiki Lee
Miki Lee
HLHaijun Li
Haijun Li
MBMayur B. Birla
Mayur B. Birla
GLGaoming Li
Gaoming Li
TWThomas Wang
Thomas Wang
KOKenn Oldham
Kenn Oldham
A flexible fiber-coupled confocal laser endomicroscope has been developed using an electrostatic micro-electro-mechanical system (MEMS) scanner located in at distal optics to collect in vivo images in human subjects. Long transmission lines are required that deliver drive and sense signals with limited bandwidth. Phase shifts have been observed between orthogonal ${X}$ - and ${Y}$ -scanner axes from environmental perturbations, which impede image reconstruction. Image-processing algorithms used for correction depend on image content and quality, while scanner calibration in the clinic can be limited by potential patient exposure to lasers. We demonstrate a capacitive sensing method to track the motion of the electrostatically driven 2-D MEMS scanner and to extract phase information needed for image reconstruction. This circuit uses an amplitude modulation (AM) envelope detection method on shared drive and sensing electrodes of the scanner. Circuit parameters were optimized for performance given high scan frequencies, transmission line effects, and substantial parasitic coupling of drive signal to circuit output. Extraction of phase information further leverages nonlinear dynamics of the MEMS scanner. The sensing circuit was verified by comparing with data from a position sensing detector (PSD) measurement. The phase estimation showed an accuracy of 2.18° and 0.79° in ${X}$ - and ${Y}$ -axes for motion sensing, respectively. The results indicate that the sensing circuit can be implemented with feedback control for precalibration of the scanner in clinical MEMS-based imaging systems.

1 September 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MBMayur Birla
Mayur Birla
XDXiyu Duan
Xiyu Duan
HLHaijun Li
Haijun Li
MLMiki Lee
Miki Lee
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
This article applies image processing metrics to tracking of perturbations in mechanical phase delay in a multiaxis microelectromechanical system scanner. The compact mirror is designed to scan a laser beam in a Lissajous pattern during the collection of endoscopic confocal fluorescence images, but environmental perturbations to the mirror dynamics can lead to image registration errors and blurry images. A binarized, threshold-based blur metric and variance-based sharpness metric are introduced for detecting scanner phase delay. Accuracy of local optima of the metric for identification of phase delay is examined, and relative advantages for processing accuracy and computational complexity are assessed. Image reconstruction is demonstrated using both generic images and sample tissue images, with significant improvement in image quality for tissue imaging. Implications of nonideal Lissajous scan effects on phase detection and image reconstruction are discussed.

12 March 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YCYi Chen
Yi Chen
MLMiki Lee
Miki Lee
MBMayur Bhushan Birla
Mayur Bhushan Birla
HLHaijun Li
Haijun Li
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
In this article, we present a method to estimate high-frequency rotary motion of a highly compact electrostatic microscanner using the same electrodes for both actuation and sensing. The accuracy of estimated rotary motion is critical for reducing blur and distortion in image reconstruction applications with the microscanner given its changing dynamics due to perturbations such as temperature. To overcome the limitation that no dedicated sensing electrodes are available in the proposed applications due to size constraints, the method adopts electromechanical amplitude modulation to separate motion signal from parasitic capacitance feedthrough, and a novel nonlinear measurement model is derived to characterize the relationship between large out-of-plane angular motion and circuit output. To estimate motion, an extended Kalman filter and an unscented Kalman filter are implemented, incorporating a process model based on the microscanner's parametric resonant dynamics and the measurement model. Experimental results show that compared to estimation without using the measurement model, our method can improve the rotary motion estimation accuracy of the microscanner significantly, with a reduction of root-mean-square error (RMSE) in phase shift of 86.1%, and a reduction of RMSE in angular position error of 78.5%.

29 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XWXiaoli Wu
Xiaoli Wu
JZJuan Zhou
Juan Zhou
FWFa Wang
Fa Wang
XMXiaoqing Meng
Xiaoqing Meng
JCJing Chen
Jing Chen
TWThomas Wang
Thomas Wang
White light colonoscopy is widely used to detect colorectal polyps, but flat and depressed lesions are often missed. Here, we report a molecular imaging strategy to potentially improve diagnostic performance by developing a fluorescently-labeled peptide specific for cMet. This 7mer is conjugated to Cy5.5, a near-infrared (NIR) cyanine dye. Specific binding to cMet was confirmed by cell staining, knockdown, and competition assays. The probe showed high binding affinity (kd = 57 nM) and fast onset (k = 1.6 min) to support topical administration in vivo. A mouse model (CPC;Apc) that develops spontaneous adenomas that overexpress cMet was used to demonstrate feasibility for real time in vivo imaging. This targeting ligand showed significantly higher target-to-background (T/B) ratio for polypoid and non-polypoid lesions by comparison with a scrambled control peptide. Immunofluorescence staining on human colon specimens show significantly greater binding to tubular and sessile serrated adenomas versus hyperplastic polyps and normal mucosa. These results demonstrate a peptide specific for cMet that is promising for endoscopic detection of pre-malignant lesions and guiding of tissue biopsy.