Haijun Li

Dr. Haijun Li

Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WSWajiha Shahid
Wajiha Shahid
ZQZhen Qiu
Zhen Qiu
XDXiyu Duan
Xiyu Duan
HLHaijun Li
Haijun Li
TWThomas Wang
Thomas Wang
KOKenn Oldham
Kenn Oldham
High frequency large scanning angle electrostatically actuated microelectromechanical systems (MEMS) mirrors are used in a variety of applications involving fast optical scanning. A 1-D parametrically resonant torsional micromirror for use in biomedical imaging is analyzed here with respect to operation by duty-cycled square waves. Duty-cycled square wave excitation can have significant advantages for practical mirror regulation and/or control. The mirror's nonlinear dynamics under such excitation is analyzed in a Hill's equation form. This form is used to predict stability regions (the voltage-frequency relationship) of parametric resonance behavior over large scanning angles using iterative approximations for nonlinear capacitance behavior of the mirror. Numerical simulations are also performed to obtain the mirror's frequency response over several voltages for various duty cycles. Frequency sweeps, stability results, and duty cycle trends from both analytical and simulation methods are compared with experimental results. Both analytical models and simulations show good agreement with experimental results over the range of duty cycled excitations tested. This paper discusses the implications of changing amplitude and phase with duty cycle for robust open-loop operation and future closed-loop operating strategies.

3 February 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GLGaoming Li
Gaoming Li
XDXiyu Duan
Xiyu Duan
MLMiki Lee
Miki Lee
MBMayur Birla
Mayur Birla
JCJing Chen
Jing Chen
HLHaijun Li
Haijun Li
Point-of-care medical diagnosis demands immediate feedback on tissue pathology. Confocal endomicroscopy can provide real-time in vivo images with histology-like features. The working channel in medical endoscopes are becoming smaller in dimension. Microsystems methods can produce tiny mechanical scanners. We demonstrate a flexible fiber instrument for in vivo imaging as an endoscope accessory. The optical path is folded on-axis to reduce length while allowing the beam to expand and achieve a numerical aperture of 0.41. A high-speed parametric resonance mirror produces large deflection angles > 13°, and is mounted on a 2 mm diameter chip designed with clamp structures for reduced space. A compact lens assembly provides diffraction-limited lateral and axial resolution of 1.5 and 12 μm , respectively. A working distance of 50 μm and field-of-view of 350 μm x 350 μm are achieved. Miniature apparatus is fabricated to assemble and align the scanhead components. The optics and scanner are packaged in a distal tip with 2.4 mm diameter and 10 mm rigid length. These dimensions allow the endomicroscope to pass forward easily through the 2.8 mm diameter working channel in medical endoscopes commonly used in clinical practice. Fluorescence images are collected in vivo at 10 frames per second in the colon of genetically-engineered mice that spontaneously develop adenomas. A FITC-labeled peptide heterodimer is administered intravenously to provide specific contrast. Sub-cellular structures are visualized to distinguish pre-malignant from normal mucosa. These results demonstrate use of microsystems methods to produce an ultra-compact instrument with sufficiently small dimensions for broad use.

15 May 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHaijun Li
Haijun Li
XDXiyu Duan
Xiyu Duan
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
TWThomas Wang
Thomas Wang
We present an electrostatic microelectromechanical systems (MEMS) resonant scanner with large out-of-plane translational stroke for fast axial-scanning in a multi-photon microscope system for real-time vertical cross-sectional imaging. The scanner has a compact footprint with dimensions of 2.1 mm × 2.1 mm × 0.44 mm, and employs a novel lever-based compliant mechanism to enable large vertical displacements of a reflective mirror with slight tilt angles. Test results show that by using parametrical resonance, the scanner can provide a fast out-of-plane translational motion with ≥400 μm displacement and ≤0.14° tilt angle over a wide frequency range of ~390 Hz at ambient pressure. By employing this MEMS translational scanner and a biaxial MEMS mirror for lateral scanning, vertical cross-sectional imaging with a beam axial-scanning range of 200 μm and a frame rate of ~5–10 Hz is enabled in a remote scan multi-photon fluorescence imaging system.

26 April 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
HLHaijun Li
Haijun Li
PBPaul Barnes
Paul Barnes
EHEric Harding
Eric Harding
XDXiyu Duan
Xiyu Duan
TWThomas Wang
Thomas Wang
KOKenn Oldham
Kenn Oldham
Electrostatic microactuators with large vertical scanning range (several hundred micrometers) at high frequency (hundreds to thousands of hertz) and chips' sizes compatible with endoscopic microscopy have recently been demonstrated based on parametric resonance. This paper examines the use and modeling of mixed softening/hardening dynamics to help produce large ranges of motion in this class of mirrors. Origin of spring stiffening behavior in actuator design is described, followed by non-dimensional analysis of actuator motion trends. The experimental results are presented for a sample actuator design with up to 480-μm displacement at 1225 Hz and 60 V. Comparison of predicted trends and comments on benefits and limitations of modeling are provided.

27 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MLMiki Lee
Miki Lee
HLHaijun Li
Haijun Li
MBMayur B. Birla
Mayur B. Birla
GLGaoming Li
Gaoming Li
TWThomas Wang
Thomas Wang
KOKenn Oldham
Kenn Oldham
A flexible fiber-coupled confocal laser endomicroscope has been developed using an electrostatic micro-electro-mechanical system (MEMS) scanner located in at distal optics to collect in vivo images in human subjects. Long transmission lines are required that deliver drive and sense signals with limited bandwidth. Phase shifts have been observed between orthogonal ${X}$ - and ${Y}$ -scanner axes from environmental perturbations, which impede image reconstruction. Image-processing algorithms used for correction depend on image content and quality, while scanner calibration in the clinic can be limited by potential patient exposure to lasers. We demonstrate a capacitive sensing method to track the motion of the electrostatically driven 2-D MEMS scanner and to extract phase information needed for image reconstruction. This circuit uses an amplitude modulation (AM) envelope detection method on shared drive and sensing electrodes of the scanner. Circuit parameters were optimized for performance given high scan frequencies, transmission line effects, and substantial parasitic coupling of drive signal to circuit output. Extraction of phase information further leverages nonlinear dynamics of the MEMS scanner. The sensing circuit was verified by comparing with data from a position sensing detector (PSD) measurement. The phase estimation showed an accuracy of 2.18° and 0.79° in ${X}$ - and ${Y}$ -axes for motion sensing, respectively. The results indicate that the sensing circuit can be implemented with feedback control for precalibration of the scanner in clinical MEMS-based imaging systems.

1 September 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MBMayur Birla
Mayur Birla
XDXiyu Duan
Xiyu Duan
HLHaijun Li
Haijun Li
MLMiki Lee
Miki Lee
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
This article applies image processing metrics to tracking of perturbations in mechanical phase delay in a multiaxis microelectromechanical system scanner. The compact mirror is designed to scan a laser beam in a Lissajous pattern during the collection of endoscopic confocal fluorescence images, but environmental perturbations to the mirror dynamics can lead to image registration errors and blurry images. A binarized, threshold-based blur metric and variance-based sharpness metric are introduced for detecting scanner phase delay. Accuracy of local optima of the metric for identification of phase delay is examined, and relative advantages for processing accuracy and computational complexity are assessed. Image reconstruction is demonstrated using both generic images and sample tissue images, with significant improvement in image quality for tissue imaging. Implications of nonideal Lissajous scan effects on phase detection and image reconstruction are discussed.