The poloidal flow velocity and the density of fully ionized carbon were measured in the Compact Helical System [K. Ida et al., Phys. Rev. Lett. 67, 58 (1991)] using the charge exchange spectroscopy with the bidirectional viewing. The poloidal asymmetry of the poloidal flow velocity observed in the outward shifted plasma is due to the electrostatic potential being constant on the magnetic flux surfaces. The poloidal asymmetry of the ion density can be explained by the conservation of the poloidal ion flux under the strong toroidal viscosity.
1 March 2002 in Plasma Physics and Controlled Fusion
A reversal of toroidal flow is observed in plasmas where a large positive electric field and a sharp electron temperature gradient are sustained inside the internal transport barrier in a compact helical system. This observation shows that the spontaneous toroidal flow in the direction anti-parallel to the Er×Bθ drift becomes large enough to reverse the toroidal flow driven by a tangentially injected neutral beam. The difference in the direction and the magnitude of the spontaneous toroidal flow are also discussed.
A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. To study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.
21 September 2021 in Plasma Physics and Controlled Fusion
We model and characterize the heat load patterns on the vacuum chamber wall in an advanced helical device, Heliotron J, based on the peripheral transport code EMC3-EIRENE, in three typical magnetic configurations with different toroidal mirror ratios (bumpiness). The heat flux distribution on the vacuum chamber wall evaluated with the EMC3-EIRENE code shows several groups of heat flux footprints, some of which are not seen in the connection length distribution obtained with the magnetic field tracing code. This clearly shows the necessity for plasma modeling in addition to magnetic field line tracing in the design of three-dimensional devices. At high electron density, a displacement and an expansion of the heat flux distribution in both the toroidal and poloidal directions are observed. As a result of the heat flux expansion, the peak value of the heat flux decreases at high electron density. Further, an approach that uses the heat distribution function is proposed to evaluate the global power distribution in the entire vacuum chamber. The evaluation results confirm a decrease in the peak heat flux and an increase in the plasma-wetted area at high electron density. The heat flux distribution expansion is larger for the low-bumpiness configuration, in which the peak heat value is by more than lower than that for the high-bumpiness configuration.
27 August 2021 in Plasma Physics and Controlled Fusion
The hydrogen/deuterium (H/D) isotope effect on a zonal flow and its configuration dependence are experimentally studied in a helical device, Heliotron J. The isotope dependence of a toroidally symmetric potential fluctuation in the frequency range of <∼4 kHz, a zonal flow, is observed in low-density electron cyclotron resonance heated plasmas in Heliotron J. In the standard configuration, the zonal flow interacting with turbulence is enhanced as the D gas fraction increases. The zonal flow is more dominated against turbulent fluctuation in D plasmas, which should have a favourable impact on turbulence transport. Interestingly, however, the opposite dependence of the zonal flow activity on the isotope ratio is also observed in the different magnetic configurations. The configuration dependence observed in this experiment could be one of the factors to explain the difference in the isotope effect of confinement improvement between tokamaks and helical devices. Impurities and radial electric field, which can also be influenced by isotope mass through the difference in neoclassical transport and plasma-wall interaction, have insignificant influences on the zonal flow behaviour in this experiment.