Robert J. Best

Robert J. Best

Auto-generated profile, based on publicly available information

Robert J. Best

The School of EEECS Queen's University Belfast Northern Ireland UK

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
PBPaul Vincent Brogan
Paul Vincent Brogan
RBRobert J. Best
Robert J. Best
DMD. John Morrow
D. John Morrow
KMKenneth McKinley
Kenneth McKinley
MKMarek L. Kubik
Marek L. Kubik
Battery energy storage system (BESS) services will be of great help when operating power systems at high renewable energy penetrations. This paper demonstrates the requirements for effective frequency and inertia services. Some system operators currently apply scalars to financially reward improved performance. This paper demonstrates a method of validating and improving these scalars by considering the delay time and ramp time of the BESS. The importance of the method used to measure the rate of change of frequency is discussed in the paper. While rate of change of frequency services improve with reduced delivery times, limits are identified where further reductions produce negligible impact. This demonstrates the tangible benefits of a rapid response and that current technology could meet the criteria. A variety of BESS capacities are trialled which demonstrate consistency in performance and the occurrence of diminishing returns.

24 August 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Ahmed A.Raouf MohamedAhmed A.Raouf Mohamed
Ahmed A.Raouf Mohamed
RBRobert J. Best
Robert J. Best
XLXueqin LIU
Xueqin LIU
DMD. John Morrow
D. John Morrow
Battery energy storage systems (BESS) are receiving great attention due to their ability in maximizing self-consumption and energy arbitrage. However, in many countries, BESS profitability is still questionable without subsidy due to their high capital costs. This paper proposes an open-source generic tool to provide comprehensive techno-economic analysis on the small-scale PV/BESS. The proposed tool utilizes real-time BESS control method that has been validated using real experimental measurements in addition to integrating a reliable degradation model to determine the loss in savings due to capacity degradation. The profitability is investigated by conducting different cost-benefit analyses for the PV and BESS. An optimization layer is introduced to find the optimal PV/BESS sizes that boost investment profitability by maximizing the net present value. A detailed case study is presented for a household in the U.K. under three different tariff structures that consider practical parameters and assumptions. Furthermore, sensitivity analyses are performed to evaluate the impact of the cost-benefit analysis assumptions on the PV/BESS sizing and profitability. Finally, the BESS investment viability is investigated over the next few years for different investment expectations to answer the question of when the BESS should be installed to be a viable economic-attractive option in the U.K.

6 October 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
RBRobert J. Best
Robert J. Best
PBPaul V. Brogan
Paul V. Brogan
DMD. John Morrow
D. John Morrow

11 October 2021 in IEEE Access
Verified
Journal Article
Open access
JLJavier Lopez Lorente
Javier Lopez Lorente
XLXueqin LIU
Xueqin LIU
RBRobert J. Best
Robert J. Best
GMGeorge Makrides
George Makrides
DMD. John Morrow
D. John Morrow
Centralised, front-of-the-meter battery energy storage systems are an option to support and add flexibility to distribution networks with increasing distributed photovoltaic systems, which generate renewable energy locally and help decarbonise the power sector. However, the provision of specific services at distribution level remains under development for real applications in industry. To this end, this paper presents an exhaustive techno-economic analysis of the role of front-of-the-meter battery energy storage systems in primary distribution networks with presence of distributed PV covering: (i) the siting decision for storage systems using multi-objective genetic algorithm optimisation; (ii) the response when smart capabilities for PV inverters (e.g., volt-var control) are present; and (iii) the quantification of revenue streams and compensation schemes that would bring positive profitability when providing distribution-specific services based on the supply of real and reactive power. The performance of grid-level battery energy storage technology is evaluated in the IEEE 34-bus system particularised to the distribution code of Northern Ireland, UK. The techno-economic assessment covers one year of simulations at 1-minute resolution performed with the simulation tool EPRI OpenDSS and its Python communication interface. The results show that, besides the technical benefits of centralised battery storage systems, the economic compensation based on traditional transmission-level services is not sufficient for the profitability of these projects. Several ideas are explored to improve the profitability of these systems considering the local value and decarbonisation they add. The findings presented can direct system operators and regulators towards developing schemes to incentivise centralised battery energy storage projects in distribution networks in the context of distribution-level services.

16 September 2023 in Electronics
Verified
Journal Article
Open access
PDF file
HMHazem Meshael
Hazem Meshael
Ahmad ElkhatebAhmad Elkhateb
Ahmad Elkhateb
RBRobert Best
Robert Best
This paper aims to investigate the state-of-the-art isolated high-step-up DC–DC topologies developed for photovoltaic (PV) systems. This study categorises the topologies into transformer-based and coupled inductor-based converters, as well as compares them in terms of various parameters such as component count, cost, voltage conversion ratio, efficiency, voltage stress, input current ripple, switching mode, and power rating. The majority of the topologies examined exhibit peak efficiencies of 90% to 97%, with voltage conversions in excess of eight, as well as power ratings ranging from 100 W to 2 kW. The existing literature has found that most isolated DC–DC converters increase their turn ratios in order to achieve high step-up ratios. As a result, voltage spikes have increased significantly in switches, resulting in a decrease in overall system efficiency. In this research, the use of passive and active snubbers to provide soft switching in isolated step-up DC–DC converters is investigated. Moreover, a comprehensive analysis of the three most widely used boost techniques is provided. A reduction in turn ratio and a decrease in voltage stress were the results of this process. The main purpose of this study is to provide a comprehensive overview of the most used high-boost isolated DC–DC topologies in PV systems, including flyback, isolated SEPIC, forward, push-pull, half- and full-bridge, and resonant converter, with a focus on the recent research in the field and the recent advancements in these topologies. This study aims to guide further research and analysis in selecting appropriately isolated topologies for PV systems.

28 March 2022 in IEEE Access
Verified
Journal Article
Open access
Ahmed A.Raouf MohamedAhmed A.Raouf Mohamed
Ahmed A.Raouf Mohamed
RBRobert J. Best
Robert J. Best
XLXueqin LIU
Xueqin LIU
DMD. John Morrow
D. John Morrow
JPJonathan Pollock
Jonathan Pollock
ACAndrew Cupples
Andrew Cupples
Distribution system operators are attracted to battery energy storage systems (BESS) as a smart option to support the distribution network. However, due to its high capital cost, BESS profitability is dependent on the participation in multiple services to stack revenues and rationalize their existence. Yet, revenue stacking is location-dependent based on the available services and regulations. In this paper, specific revenue stacking frameworks are proposed for BESS installed in modern distribution networks that consider the conflicts and synergies that may occur from the involvement in multiple services in practice. A simple yet effective sizing formulation is introduced to find the BESS system size based on the primary service which is to solve the distribution network violations. BESS scheduling is simulated in accordance with the proposed frameworks to maximize the stackable profits for a case study of Northern Ireland. The BESS profitability is investigated through cost-benefit analyses of different technologies for the sole and stacked services. The results show that revenue stacking can boost the annual revenues by 129% with a payback period of 8 years on average. The presented insights are useful for network operators and energy investors in understanding and assessing the profitability of different BESS technologies for various applications.