Osvaldo Loquiha

Osvaldo Loquiha

Auto-generated profile, based on publicly available information

Osvaldo Loquiha

Clinton Health Access Initiative, Maputo, Mozambique

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
OLOsvaldo Loquiha
Osvaldo Loquiha
NHNiel Hens
Niel Hens
LCLeonardo Chavane
Leonardo Chavane
MTMarleen Temmerman
Marleen Temmerman
NONafissa Osman
Nafissa Osman
MAMarc Aerts
Marc Aerts
Maternal mortality remains very high in Mozambique, with estimates from 2015 showing a maternal mortality ratio of 489 deaths per 100,000 live births, even though the rates tend to decrease since 1990. Pregnancy related hemorrhage, gestational hypertension and diseases such as malaria and HIV/AIDS are amongst the leading causes of maternal death in Mozambique, and a significant number of these deaths occur within health facilities. Often, the analysis of data on maternal mortality involves the use of counts of maternal deaths as outcome variable. Previously we showed that a class of hierarchical zero-inflated models were very successful in dealing with overdispersion and clustered counts when analyzing data on maternal deaths and related risk factors within health facilities in Mozambique. This paper aims at providing additional insights over previous analyses and presents an extension of such models to account for spatial variation in a disease mapping framework of facility-based maternal mortality in Mozambique.

12 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NSNádia Sitoe
Nádia Sitoe
JAJúlia Sambo Abchande
Júlia Sambo Abchande
NNNeuza Nguenha
Neuza Nguenha
JCJorfelia Jose Chilaule
Jorfelia Jose Chilaule
ICImelda Rogerio Chelene
Imelda Rogerio Chelene
IJIlesh Jani
Ilesh Jani
(1) Background: Laboratory-based molecular assays are the gold standard to detect SARS-CoV-2. In resource-limited settings, the implementation of these assays has been hampered by operational challenges and long turnaround times. Rapid antigen detection tests are an attractive alternative. Our aim is to evaluate the clinical performance of two SARS-CoV-2 rapid antigen tests during a high transmission period. (2) Methods: A total of 1277 patients seeking SARS-CoV-2 diagnosis were enrolled at four health facilities. Nasopharyngeal swabs for rapid antigen and real time PCR testing were collected for each patient. Sensitivity, specificity, positive and negative predictive values, misclassification rate, and agreement were determined. (3) Results: The overall sensitivity of Panbio COVID-19 was 41.3% (95% CI: 34.6–48.4%) and the specificity was 98.2% (95% CI: 96.2–99.3%). The Standard Q had an overall sensitivity and specificity of 45.0% (95% CI: 39.9–50.2%) and 97.6% (95% CI: 95.3–99.0%), respectively. The positive predictive value of a positive test was 93.3% and 95.4% for the Panbio and Standard Q Ag-RDTs, respectively. A higher sensitivity of 43.2% and 49.4% was observed in symptomatic cases for the Panbio and Standard Q Ag-RDTs, respectively. (4) Conclusions: Despite the overall low sensitivity, the two evaluated rapid tests are useful to improve the diagnosis of symptomatic SARS-CoV-2 infections during high transmission periods.

19 September 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
NSNádia Sitoe
Nádia Sitoe
JAJúlia Sambo Abchande
Júlia Sambo Abchande
NMNédio Mabunda
Nédio Mabunda
NNNeuza Nguenha
Neuza Nguenha
JCJorfélia Chilaúle
Jorfélia Chilaúle
IJIlesh Jani
Ilesh Jani
Background: In resource-poor countries, antigen-based rapid tests (Ag-RDTs) performed at primary healthcare and community settings improved access to SARS-CoV-2 diagnostics. However, the technical skills and biosafety requirements inherent to nasopharyngeal and oropharyngeal (OP) specimens limit the scale-up of SARS-CoV-2 testing. The collection of nasal-swabs is programmatically viable, but its performance has not been evaluated in resource-poor settings. Methods: We first evaluated the performance of SteriPack self-collected nasal swabs for the detection of SARS-CoV-2 by real-time PCR in 1498 consecutively enrolled patients with suspected infection. Next, we evaluated the clinical performance of three nasal swab-based Ag-RDTs against real-time PCR on OP specimens. Results: The sensitivity of nasal swabs was 80.6% [95% CI: 75.3–85.2%] compared to OP specimens. There was a good correlation (r = 0.58; p < 0.0001) between Ct values of 213 positive cases obtained using nasal and OP swabs. Our findings show sensitivities of 79.7% [95% CI: 73.3–85.1%] for Panbio COVID-19 Ag-RDT, 59.6% [95% CI: 55.2–63.8%] for COVIOS Ag-RDT, and 78.0% [95% CI: 73.5–82.0%] for the LumiraDx SARS-CoV-2 Ag-RDT. Conclusions: In our setting, the COVIOS Ag-RDT did not meet WHO requirements. Nasal swab-based Ag-RDTs for SARS-CoV-2 detection constitute a viable and accurate diagnostic option in resource-poor settings.

31 January 2017 in Journal of Obstetrics and Gynaecology
Verified
Journal Article
Closed access
LCLeonardo Chavane
Leonardo Chavane
MDMartinho Dgedge
Martinho Dgedge
ODOlivier Degomme
Olivier Degomme
OLOsvaldo Loquiha
Osvaldo Loquiha
MAMarc Aerts
Marc Aerts
MTMarleen Temmerman
Marleen Temmerman
Facility-based maternal mortality remains an important public health problem in Mozambique. A number of factors associated with health system functioning can be described behind the occurrence of these deaths. This paper aimed to evaluate the magnitude of the health facility-based maternal mortality, its geographical distribution and to assess the health facility factors implicated in the occurrence of these deaths. A secondary analysis was done on data from the survey on maternal health needs performed by the Ministry of Health of Mozambique in 2008. During the study period 2.198 maternal deaths occurred out of 312.537 deliveries. According to the applied model the availability of Maternal and Child Health (MCH) nurses performing Emergency Obstetric Care functions was related to the reduction of facility-based maternal mortality by 40%. No significant effects were observed for the availability of medical doctors, surgical technicians and critical delivery room equipment.

5 July 2013 in Biometrical Journal
Verified
Journal Article
Closed access
PDF file
OLOsvaldo Loquiha
Osvaldo Loquiha
NHNiel Hens
Niel Hens
LCLeonardo Chavane
Leonardo Chavane
MTMarleen Temmerman
Marleen Temmerman
MAMarc Aerts
Marc Aerts

8 January 2020 in Journal of the International AIDS Society
Verified
Journal Article
Open access
PDF file
AVAdolfo Vubil
Adolfo Vubil
CNCarina Nhachigule
Carina Nhachigule
OLOsvaldo Loquiha
Osvaldo Loquiha
BMBindiya Meggi
Bindiya Meggi
NMNédio Mabunda
Nédio Mabunda
LVLara Vojnov
Lara Vojnov
Introduction: Viral load testing is essential to manage HIV disease, especially in infants and children. Early infant diagnosis (EID) is performed using nucleic‐acid testing in children under 18 months. Resource‐limited health systems face severe challenges to scale‐up both viral load and EID to unprecedented levels. Streamlining laboratory systems would be beneficial to improve access to quality testing and to increase efficiency of antiretroviral treatment programmes. We evaluated the performance of viral load testing to serve as an EID assay in children younger than 18 months.Methods: This study was an observational, prospective study, including children between one and 18 months of age who were born to HIV‐positive mothers in 134 health facilities in Maputo City and Maputo Province, Mozambique. Dried blood spot specimens from heel or toe pricks were collected between January and April 2018, processed using SPEX buffer for both assays, and tested for routine EID and viral load testing using the Roche CAP/CTM HIV‐1 Qualitative v2 and Roche CAP/CTM HIV‐1 Quantitative v2 assays respectively. The sensitivity, specificity and positive and negative predictive values were estimated using the EID results as the reference standard.Results: A total of 1021 infants were included in the study, of which 47% were female. Over 95% of mothers and children were on antiretroviral treatment or received antiretroviral prophylaxis respectively. The sensitivity and specificity of using the viral load assay to detect infection were 100% (95% CI: 96.2 to 100%) and 99.9% (95% CI: 99.4 to 100%). The positive and negative predictive values were 99.0% (95% CI: 94.3 to 100%) and 100% (95% CI: 99.6 to 100%). The McNemar’s test was 1.000 and Cohen’s kappa was 0.994.Conclusions: The comparable performance suggests that viral load assays can be used as an infant diagnostic assay. Infants with either low levels of viraemia or high cycle threshold values should be repeat tested to ensure the result is truly positive prior to treatment initiation, regardless of assay used. Viral load assays could replace traditional EID testing, substantially streamlining molecular laboratory services for children and lowering costs, with the additional advantage of providing baseline viral load results for antiretroviral treatment management.