Carlos Balsalobre-Fernández

Dr. Carlos Balsalobre-Fernández

Universidad Autónoma de Madrid, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2015 in Journal of Sports Sciences
Verified
Journal Article
Closed access
Carlos Balsalobre-FernándezCarlos Balsalobre-Fernández
Carlos Balsalobre-Fernández
MGMark Glaister
Mark Glaister
RLRichard Anthony Lockey
Richard Anthony Lockey
The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach’s alpha (α), coefficient of variation and Bland–Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland–Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (r = 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.

3 November 2016 in European Journal of Sport Science
Verified
Journal Article
Closed access
Natalia Romero-FrancoNatalia Romero-Franco
Natalia Romero-Franco
PJPedro Jiménez‐Reyes
Pedro Jiménez‐Reyes
ACAdrián Castaño‐Zambudio
Adrián Castaño‐Zambudio
FCFernando Capelo‐Ramírez
Fernando Capelo‐Ramírez
JRJuan José Rodríguez-Juan
Juan José Rodríguez-Juan
Carlos Balsalobre-FernándezCarlos Balsalobre-Fernández
Carlos Balsalobre-Fernández
The purpose of this study was to assess validity and reliability of sprint performance outcomes measured with an iPhone application (named: MySprint) and existing field methods (i.e. timing photocells and radar gun). To do this, 12 highly trained male sprinters performed 6 maximal 40‐m sprints during a single session which were simultaneously timed using 7 pairs of timing photocells, a radar gun and a newly developed iPhone app based on high‐speed video recording. Several split times as well as mechanical outputs computed from the model proposed by Samozino et al. [(2015). A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/sms.12490] were then measured by each system, and values were compared for validity and reliability purposes. First, there was an almost perfect correlation between the values of time for each split of the 40‐m sprint measured with MySprint and the timing photocells (r = 0.989–0.999, standard error of estimate = 0.007–0.015 s, intraclass correlation coefficient (ICC) = 1.0). Second, almost perfect associations were observed for the maximal theoretical horizontal force (F0), the maximal theoretical velocity (V0), the maximal power (Pmax) and the mechanical effectiveness (DRF – decrease in the ratio of force over acceleration) measured with the app and the radar gun (r = 0.974–0.999, ICC = 0.987–1.00). Finally, when analysing the performance outputs of the six different sprints of each athlete, almost identical levels of reliability were observed as revealed by the coefficient of variation (MySprint: CV = 0.027–0.14%; reference systems: CV = 0.028–0.11%). Results on the present study showed that sprint performance can be evaluated in a valid and reliable way using a novel iPhone app.

1 February 2014 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Carlos Balsalobre-FernándezCarlos Balsalobre-Fernández
Carlos Balsalobre-Fernández
CTCarlos Mª Tejero-González
Carlos Mª Tejero-González
JCJuan del Campo-Vecino
Juan del Campo-Vecino
NBNicolás Bavaresco
Nicolás Bavaresco
Flight time is the most accurate and frequently used variable when assessing the height of vertical jumps. The purpose of this study was to analyze the validity and reliability of an alternative method (i.e., the HSC-Kinovea method) for measuring the flight time and height of vertical jumping using a low-cost high-speed Casio Exilim FH-25 camera (HSC). To this end, 25 subjects performed a total of 125 vertical jumps on an infrared (IR) platform while simultaneously being recorded with a HSC at 240 fps. Subsequently, 2 observers with no experience in video analysis analyzed the 125 videos independently using the open-license Kinovea 0.8.15 software. The flight times obtained were then converted into vertical jump heights, and the intraclass correlation coefficient (ICC), Bland-Altman plot, and Pearson correlation coefficient were calculated for those variables. The results showed a perfect correlation agreement (ICC = 1, p < 0.0001) between both observers' measurements of flight time and jump height and a highly reliable agreement (ICC = 0.997, p < 0.0001) between the observers' measurements of flight time and jump height using the HSC-Kinovea method and those obtained using the IR system, thus explaining 99.5% (p < 0.0001) of the differences (shared variance) obtained using the IR platform. As a result, besides requiring no previous experience in the use of this technology, the HSC-Kinovea method can be considered to provide similarly valid and reliable measurements of flight time and vertical jump height as more expensive equipment (i.e., IR). As such, coaches from many sports could use the HSC-Kinovea method to measure the flight time and height of their athlete's vertical jumps.

1 July 2016 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
FGFrancisco Gallardo-Fuentes
Francisco Gallardo-Fuentes
JGJorge Gallardo-Fuentes
Jorge Gallardo-Fuentes
Rodrigo Ramirez-CampilloRodrigo Ramirez-Campillo
Rodrigo Ramirez-Campillo
Carlos Balsalobre-FernándezCarlos Balsalobre-Fernández
Carlos Balsalobre-Fernández
CMCristian Martínez
Cristian Martínez
Mikel IzquierdoMikel Izquierdo
Mikel Izquierdo
Gallardo-Fuentes, F, Gallardo-Fuentes, J, Ramírez-Campillo, R, Balsalobre-Fernández, C, Martínez, C, Caniuqueo, A, Cañas, R, Banzer, W, Loturco, I, Nakamura, FY, and Izquierdo, M. Intersession and intrasession reliability and validity of the My Jump app for measuring different jump actions in trained male and female athletes. J Strength Cond Res 30(7): 2049–2056, 2016—The purpose of this study was to analyze the concurrent validity and reliability of the iPhone app named My Jump for measuring jump height in 40-cm drop jumps (DJs), countermovement jumps (CMJs), and squat jumps (SJs). To do this, 21 male and female athletes (age, 22.1 ± 3.6 years) completed 5 maximal DJs, CMJs, and SJs on 2 separate days, which were evaluated using a contact platform and the app My Jump, developed to calculate jump height from flight time using the high-speed video recording facility on the iPhone. A total of 630 jumps were compared using the intraclass correlation coefficient (ICC), Bland-Altman plots, Pearson's product moment correlation coefficient (r), Cronbach's alpha (α), and coefficient of variation (CV). There was almost perfect agreement between the measurement instruments for all jump height values (ICC = 0.97–0.99), with no differences between the instruments (p > 0.05; mean difference of 0.2 cm). Almost perfect correlation was observed between the measurement instruments for SJs, CMJs, and DJs (r = 0.96–0.99). My Jump showed very good within-subject reliability (α = 0.94–0.99; CV = 3.8–7.6) and interday reliability (r = 0.86–0.95) for SJs, CMJs, and DJs in all subjects. Therefore, the iPhone app named My Jump provides reliable intersession and intrasession data, as well as valid measurements for maximal jump height during fast (i.e., DJs) and slow (i.e., CMJs) stretch-shortening cycle muscle actions, and during concentric-only explosive muscle actions (i.e., SJs), in both male and female athletes in comparison with a professional contact platform.

1 August 2016 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
PDF file
Carlos Balsalobre-FernándezCarlos Balsalobre-Fernández
Carlos Balsalobre-Fernández
Jordan Santos-ConcejeroJordan Santos-Concejero
Jordan Santos-Concejero
Gerasimos GrivasGerasimos Grivas
Gerasimos Grivas
Balsalobre-Fernández, C, Santos-Concejero, J, and Grivas, GV. Effects of strength training on running economy in highly trained runners: a systematic review with meta-analysis of controlled trials. J Strength Cond Res 30(8): 2361–2368, 2016—The purpose of this study was to perform a systematic review and meta-analysis of controlled trials to determine the effect of strength training programs on the running economy (RE) of high-level middle- and long-distance runners. Four electronic databases were searched in September 2015 (PubMed, SPORTDiscus, MEDLINE, and CINAHL) for original research articles. After analyzing 699 resultant original articles, studies were included if the following criteria were met: (a) participants were competitive middle- or long-distance runners; (b) participants had a V̇o 2max >60 ml·kg−1·min−1; (c) studies were controlled trials published in peer-reviewed journals; (d) studies analyzed the effects of strength training programs with a duration greater than 4 weeks; and (e) RE was measured before and after the strength training intervention. Five studies met the inclusion criteria, resulting in a total sample size of 93 competitive, high-level middle- and long-distance runners. Four of the 5 included studies used low to moderate training intensities (40–70% one repetition maximum), and all of them used low to moderate training volume (2–4 resistance lower-body exercises plus up to 200 jumps and 5–10 short sprints) 2–3 times per week for 8–12 weeks. The meta-analyzed effect of strength training programs on RE in high-level middle- and long-distance runners showed a large, beneficial effect (standardized mean difference [95% confidence interval] = −1.42 [−2.23 to −0.60]). In conclusion, a strength training program including low to high intensity resistance exercises and plyometric exercises performed 2–3 times per week for 8–12 weeks is an appropriate strategy to improve RE in highly trained middle- and long-distance runners.

1 April 2018 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
Amador Garcia RamosAmador Garcia Ramos
Amador Garcia Ramos
GHGuy Gregory Haff
Guy Gregory Haff
FPFrancisco Luis Pestaña-Melero
Francisco Luis Pestaña-Melero
Alejandro Pérez-CastillaAlejandro Pérez-Castilla
Alejandro Pérez-Castilla
FRFrancisco Javier Rojas
Francisco Javier Rojas
SJSlobodan Jaric
Slobodan Jaric
Purpose:This study compared the concurrent validity and reliability of previously proposed generalized group equations for estimating the bench press (BP) one-repetition maximum (1RM) with the individualized load-velocity relationship modelled with a two-point method. Methods:Thirty men (BP 1RM relative to body mass: 1.08 0.18 kg·kg-1) performed two incremental loading tests in the concentric-only BP exercise and another two in the eccentric-concentric BP exercise to assess their actual 1RM and load-velocity relationships. A high velocity (≈ 1 m·s-1) and a low velocity (≈ 0.5 m·s-1) was selected from their load-velocity relationships to estimate the 1RM from generalized group equations and through an individual linear model obtained from the two velocities. Results:The directly measured 1RM was highly correlated with all predicted 1RMs (r range: 0.847–0.977). The generalized group equations systematically underestimated the actual 1RM when predicted from the concentric-only BP (P <0.001; effect size [ES] ...