Carla Otero Currás

Mrs. Carla Otero Currás

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CCCarla Otero Currás
Carla Otero Currás
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
PRPilar Rojas
Pilar Rojas
RJRut González Jiménez
Rut González Jiménez
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
Background: Acquired brain injury (ABI) often disrupts binocular vision, causing deviations on the cover test and reduced stereopsis that impair functional visual performance. This study investigated the effects of a dichoptic vision therapy protocol—based on an immersive virtual reality (VR) system—on visual field parameters, oculomotor reaction times, and self-reported visual symptoms in adults with ABI. Methods: In a controlled parallel-group design, adult ABI patients (median age 51 years) were assigned to an experimental group (dichoptic VR therapy) or a control group. Six sessions of visual therapy were performed. Primary outcomes included perimetric visual field indices and oculomotor reaction times; the secondary outcome was the Brain Injury Vision Symptom Survey (BIVSS) score. Etiology (stroke vs. traumatic brain injury) was recorded. Results: No statistically significant improvements were found in perimetric visual field indices (p > 0.05), except for a slight gain in the top-right quadrant in the experimental group. Reaction times did not differ significantly between groups. However, the experimental group reported a greater reduction in visual symptoms as measured by the BIVSS. Patients with traumatic brain injury exhibited better functional improvement, particularly in the top-left quadrant (p = 0.04). Conclusions: Dichoptic VR-based therapy did not restore perimetric field losses in ABI patients but reduced visual symptoms and may enhance functional adaptation of residual vision rather than structural recovery. The therapeutic response varied by etiology, favoring traumatic brain injury. Larger, longer trials integrating objective and subjective measures, including neuroimaging, are warranted.

27 November 2025 in Photonics
Verified
Journal Article
Open access
PDF file
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
José Ramón TrilloJosé Ramón Trillo
José Ramón Trillo
RJRut González Jiménez
Rut González Jiménez
CCCarla Otero Currás
Carla Otero Currás
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
Background: Eye-tracking technology enables the objective quantification of oculomotor behavior, providing key insights into visuocognitive performance. This study presents a comparative analysis of visual attention patterns between rhythmic gymnasts and school-aged students using an optical eye-tracking system combined with machine learning algorithms. Methods: Eye movement data were recorded during controlled visual tasks using the DIVE system (sampling rate: 120 Hz). Spatiotemporal metrics—including fixation duration, saccadic amplitude, and gaze entropy—were extracted and used as input features for supervised models: Support Vector Machine (SVM), k-Nearest Neighbors (k-NN), Decision Tree (CART), Random Forest, XGBoost, and a one-dimensional Convolutional Neural Network (1D-CNN). Data were divided according to a hold-out scheme (70/30) and evaluated using accuracy, F1-macro score, and Receiver Operating Characteristic (ROC) curves. Results: XGBoost achieved the best performance (accuracy = 94.6%; F1-macro = 0.945), followed by Random Forest (accuracy = 94.0%; F1-macro = 0.937). The neural network showed intermediate performance (accuracy = 89.3%; F1-macro = 0.888), whereas SVM and k-NN exhibited lower values. Gymnasts demonstrated more stable and goal-directed gaze patterns than students, reflecting greater efficiency in visuomotor control. Conclusions: Integrating eye-tracking with artificial intelligence provides a robust framework for the quantitative assessment of visuocognitive performance. Ensemble algorithms demonstrated high discriminative power, while neural networks require further optimization. This approach shows promising applications in sports science, cognitive diagnostics, and the development of adaptive human–machine interfaces.

29 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
LSLaura Sánchez-Alamillos
Laura Sánchez-Alamillos
MGMarina Medina Galdeano
Marina Medina Galdeano
CCCarla Otero Currás
Carla Otero Currás
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Background: Automated visual field testing is fundamental in ophthalmology, but differences in stimulus scaling and luminance between devices hinder direct comparison of sensitivity values. Virtual reality (VR)-based perimetry has emerged as a portable alternative, yet its relationship with conventional perimetry requires clarification. Methods: This prospective cross-sectional study included 60 healthy participants stratified into younger (<50 years) and older (≥50 years) groups. Differential light sensitivity was assessed in the right eye using Humphrey Automated Perimetry (HFA) with the 30-2 test pattern and a VR-based perimeter (Dicopt-Pro) in randomized order. Pointwise sensitivity values were analyzed using linear regression and Bland–Altman analysis, and sensitivity profiles were examined as a function of visual field eccentricity. Results: A strong linear relationship was observed between HFA and Dicopt-Pro sensitivity values in both age groups (R ≥ 0.96). A systematic and approximately constant inter-device offset was identified, with mean differences of 15.7 ± 0.4 dB in younger subjects and 13.7 ± 0.5 dB in older subjects. Bland–Altman analysis showed consistent bias without proportional error. Dicopt-Pro sensitivity profiles demonstrated an eccentricity-dependent decline comparable to HFA while preserving age-related differences. Conclusions: VR-based perimetry using Dicopt-Pro shows sensitivity patterns closely aligned with conventional Humphrey perimetry when a systematic, age-specific inter-device offset is considered, enabling clinically meaningful interpretation of Dicopt-Pro results within an HFA-referenced framework.

21 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
SBSilvia Burgos
Silvia Burgos
RJRut González Jiménez
Rut González Jiménez
CCCarla Otero Currás
Carla Otero Currás
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Background: Sensor-based systems and virtual reality (VR) technologies provide new opportunities for the objective, technology-driven assessment and training of visuomotor performance in applied contexts such as sport. Methods: This study examined the effects of an integrated visual training program combining stroboscopic stimulation, VR-based vergence exercises, and instrumented reaction-light tasks in adolescent handball players. Twenty-eight adolescent handball players (under-18 competitive level) completed two baseline assessments separated by six weeks, followed by a six-session training program (approximately 15 min per session) integrated into regular team practice. The intervention targeted visuomotor reaction speed, accommodative dynamics, and peripheral visual responsiveness using sensor-based and virtual reality–assisted stimuli. Results: Compared with both baseline measurements, the intervention produced selective improvements in accommodative facility (cycles per minute, cpm)—particularly near–far focusing speed—and in multiple reaction-time conditions (milliseconds, ms) involving manual and decision-based responses. Specific peripheral-field locations showed increased response scores, whereas binocular alignment, AC/A ratio, near phoria, and stereoscopic acuity remained unchanged. Conclusions: These findings indicate that technology-supported visual training protocols incorporating sensor-based reaction systems and VR stimuli were associated with measurable adaptations in dynamic visuomotor processing while preserving fundamental binocular vision parameters.

28 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
José Ramón TrilloJosé Ramón Trillo
José Ramón Trillo
RJRut González Jiménez
Rut González Jiménez
CCCarla Otero Currás
Carla Otero Currás
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
Background: Eye-tracking technology enables the objective quantification of oculomotor behavior, providing key insights into visuocognitive performance. This study presents a comparative analysis of visual attention patterns between rhythmic gymnasts and school-aged students using an optical eye-tracking system combined with machine learning algorithms. Methods: Eye movement data were recorded during controlled visual tasks using the DIVE system (sampling rate: 120 Hz). Spatiotemporal metrics—including fixation duration, saccadic amplitude, and gaze entropy—were extracted and used as input features for supervised models: Support Vector Machine (SVM), k-Nearest Neighbors (k-NN), Decision Tree (CART), Random Forest, XGBoost, and a one-dimensional Convolutional Neural Network (1D-CNN). Data were divided according to a hold-out scheme (70/30) and evaluated using accuracy, F1-macro score, and Receiver Operating Characteristic (ROC) curves. Results: XGBoost achieved the best performance (accuracy = 94.6%; F1-macro = 0.945), followed by Random Forest (accuracy = 94.0%; F1-macro = 0.937). The neural network showed intermediate performance (accuracy = 89.3%; F1-macro = 0.888), whereas SVM and k-NN exhibited lower values. Gymnasts demonstrated more stable and goal-directed gaze patterns than students, reflecting greater efficiency in visuomotor control. Conclusions: Integrating eye-tracking with artificial intelligence provides a robust framework for the quantitative assessment of visuocognitive performance. Ensemble algorithms demonstrated high discriminative power, while neural networks require further optimization. This approach shows promising applications in sports science, cognitive diagnostics, and the development of adaptive human–machine interfaces.

29 May 2026 in Children
Verified
Journal Article
Open access
PDF file
RJRut González Jiménez
Rut González Jiménez
José Ramón TrilloJosé Ramón Trillo
José Ramón Trillo
Ricardo Bernardez-VilaboaRicardo Bernardez-Vilaboa
Ricardo Bernardez-Vilaboa
Juan E. Cedrún-SánchezJuan E. Cedrún-Sánchez
Juan E. Cedrún-Sánchez
CCCarla Otero Currás
Carla Otero Currás
Francisco Javier Povedano-MonteroFrancisco Javier Povedano-Montero
Francisco Javier Povedano-Montero
Background/Objectives: Efficient visual processing is relevant for reading, writing, and sustained attention in schoolchildren. However, the relative discriminative value of different visual domains for identifying teacher-reported academic difficulties remains unclear. This study evaluated five visual system alteration domains for identifying teacher-reported academic difficulties using machine learning models. Methods: An observational analytical study was conducted in 581 primary schoolchildren. After complete-case analysis, 506 participants were included in the machine-learning analyses. Academic functioning was rated by teachers using a 1–5 ordinal scale and dichotomized as a pragmatic school-based indicator of teacher-reported academic difficulties. Five predictor groups were analyzed: DIVE-based oculomotor function, clinical oculomotor assessment, accommodative system, vergence system, and axial length. Five classifiers were evaluated using stratified 5-fold cross-validation combined with model-complexity penalization through hyperparameter optimization. Results: The accommodative system showed the highest cross-validated performance (XGBoost: accuracy 0.952 ± 0.021; macro-F1 0.919 ± 0.028), followed by clinically assessed and instrumentally assessed oculomotor predictors. Oculomotor alterations also showed strong performance, whereas vergence alterations showed high specificity but very low sensitivity, and abnormal axial length showed limited discriminative performance. Conclusions: Functional visual domains, particularly accommodation and oculomotor control, showed stronger cross-validated classification performance than vergence or axial-length variables. These findings are exploratory and require external validation cohorts, standardized academic outcomes, and future combined-domain modeling before clinical or educational implementation.