Carlos Rincón

Mr. Carlos Rincón

Pontificia Universidad Católica del Perú
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
Carlos RincónCarlos Rincón
Carlos Rincón
JMJorge Hernan Alencastre Miranda
Jorge Hernan Alencastre Miranda
RRRichard Rivera
Richard Rivera
Attenuation of mechanical vibrations is an ongoing field of research in engineering aiming at reducing damage and improving performance in the presence of dynamical forces. Different alternatives have been proposed over time; the active vibration absorber can be highlighted as an alternative which can absorb the vibration from system in real time. In this study, an active vibration absorber was modelled as an electromechanical device. It was applied to a cantilever beam, mathematically modelled as a continuous beam. A set of differential equations representing the dynamical behaviour of the cantilever beam and active vibration absorber was obtained and it was simulated in Matlab Simulink®. Results indicated that the active vibration absorber is able to significantly reduce the vibration amplitudes of a system, especially in resonance conditions. The analytical model and procedure developed here can easily spread to any more complex system.

9 November 2020 in Agriculture
Verified
Journal Article
Open access
PDF file
Carlos RincónCarlos Rincón
Carlos Rincón
Marco Tejada CardeñaMarco Tejada Cardeña
Marco Tejada Cardeña
Juan José Jiménez de Cisneros FonfríaJuan José Jiménez de Cisneros Fonfría
Juan José Jiménez de Cisneros Fonfría
This article presents the design and analysis of an automatic shell broken machine of seeds of Metohuayo (“Caryodendron orinocense Karst”) with a production capacity of 50 kg/h, considering manufacturing and maintenance of local facilities. Metohuayo is the fruit of a tree that grows in various jungle areas of Perú, and the Metohuayo oil is very requested because of its nutritional properties. Starting with these specifications, the design was developed according to the systematic approach established by the VDI-2221 standard, with seven basic steps to analyze the optimum design. Once the definitive project was reached and the commercial components were selected, finite element simulations were performed to analyze the strength of the shell broken system and to evaluate the strength and the dynamic response of the structural support of the machine components. Additionally, complementary experimental studies were performed, such as the analysis of the required force to break the shell or the measurement of their dimensions.

8 July 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
JCJESUS ALAN CALDERON CHAVARRI
JESUS ALAN CALDERON CHAVARRI
Carlos RincónCarlos Rincón
Carlos Rincón
AAAna María Gómez Amador
Ana María Gómez Amador
BCBray Jesús Martin Agreda Cardenas
Bray Jesús Martin Agreda Cardenas
SASebastián Calero Anaya
Sebastián Calero Anaya
Juan José Jiménez de Cisneros FonfríaJuan José Jiménez de Cisneros Fonfría
Juan José Jiménez de Cisneros Fonfría
Mechanical ventilation systems require a device for measuring the air flow provided to a patient in order to monitor and ensure the correct quantity of air proportionated to the patient, this device is the air flow sensor. At the beginning of the COVID-19 pandemic, flow sensors were not available in Peru because of the international supply shortage. In this context, a novel air flow sensor based on an orifice plate and an intelligent transducer was developed to form an integrated device. The proposed design was focused on simple manufacturing requirements for mass production in a developing country. CAD and CAE techniques were used in the design stage, and a mathematical model of the device was proposed and calibrated experimentally for the measured data transduction. The device was tested in its real working conditions and was therefore implemented in a breathing circuit connected to a low-cost mechanical ventilation system. Results indicate that the designed air flow sensor/transducer is a low-cost complete medical device for mechanical ventilators that is able to provide all the ventilation parameters by an equivalent electrical signal to directly display the following factors: air flow, pressure and volume over time. The evaluation of the designed sensor transducer was performed according to sundry transducer parameters such as geometrical parameters, material parameters and adaptive coefficients in the main transduction algorithm; in effect, the variety of the described results were achieved by the faster response time and robustness proportionated by transducers of nanostructures based on Anodic Aluminum Oxide (AAO), which enhanced the designed sensor/transducer (ST) during operation in intricate geographic places, such as the Andes mountains of Peru.

4 July 2024 in South Florida Journal of Development
Verified
Journal Article
Open access
PDF file
Carlos RincónCarlos Rincón
Carlos Rincón
JAJorge Alencastre
Jorge Alencastre
EBEnrique Barrantes
Enrique Barrantes
CCCecilia Carbajal
Cecilia Carbajal
Water shortage is one of the major issues in the world. The consequences can impact negatively on the develop of a location. Puno is an arid region located in Peru. There have been different problems related to water shortage in recent years. Some communities use a waterhole filled by precipitation as a source of water. This is usually far from their communities, then they have to transport manually buckets of water by waking. In this paper, we establish a design procedure of an atmospheric water generator (AWG) located at Puno with a capacity of 40L per day in order to deal with the water shortage. Current AWGs are designed for locations with favorable climatic conditions as high relative humidity (RH). However, they wouldn't be able to operate in dried seasons as at Puno with RH under 25%. An adsorption process is implemented as an additional module in order to compensate the low ambient temperature and RH during the worst climatic conditions from June to August. An analytic model of dehumidification by a heat exchanger was developed in order to quantify influence of parameters as climatic conditions and mass fluxes. Results showed that the design is capable to produce water during all the variable climactic conditions over the year. Numerical simulations of the analytic model indicated that the system can produce water by direct cooling in most months without the support of adsorption process.

20 January 2021 in Preprints.org
Verified
Preprint
Open access
JCJESUS ALAN CALDERON CHAVARRI
JESUS ALAN CALDERON CHAVARRI
Carlos RincónCarlos Rincón
Carlos Rincón
BABray Agreda
Bray Agreda
SCSebastián Calero
Sebastián Calero
MBManuel Bornas
Manuel Bornas
Juan José Jiménez de Cisneros FonfríaJuan José Jiménez de Cisneros Fonfría
Juan José Jiménez de Cisneros Fonfría
Mechanical ventilation systems, which are used for breathing support when a person is not able to do it by their own, requires a device for measuring the air flow to the patient in order to monitoring and a assure the magnitude establish by a medical staff. Flow sensors are the conventional devices used for the air flow measuring; however, there were not available in Peru, because of the international demand during COVID-19 pandemic. In this sense, a novel air flow sensor based on orifice plate and an intelligent transducer stage were developed as an integrated design. Advanced methodologies in simulations and experiments using specially designed equipment for this application were carried out. The obtained data was used for a mathematical characterization and dimensions validation of the integrated design. The device was tested in its real working conditions, it was implemented in a breathing circuit connected to a low-cost mechanical ventilation system based on cams. Results indicate that the designed air flow sensor/transducer is a low-cost complete medical device for mechanical ventilators able to provide satisfactorily all the ventilation parameters air flow, pressure and volume over time by measuring the air flow and calculating the others. Furthermore, this device provides directly a filtered equivalent electrical signal for a display or a computer.

17 December 2020 in Preprints.org
Verified
Preprint
Open access
JCJESUS ALAN CALDERON CHAVARRI
JESUS ALAN CALDERON CHAVARRI
Carlos RincónCarlos Rincón
Carlos Rincón
BABray Agreda
Bray Agreda
Juan José Jiménez de Cisneros FonfríaJuan José Jiménez de Cisneros Fonfría
Juan José Jiménez de Cisneros Fonfría
A mechanical ventilation system is a big support for breathing complications, in which an external solution is quite necessary to keep oxygen compensation in the patients. Its knowledge is well widespread and different equipment has been developed. However, they are very expensive and their quantity in medical centers is not sufficient, especially in Peru. Hence, it has been required to develop new methods to provide oxygen by a low cost equipment; Protofy, a research group from Spain, designed one of the first low cost mechanical ventilation systems which was medically validated by its government. In this sense, a redesign of the mechanical ventilation system was carried out according to the local requirements and available technology, a different airbag resuscitator with different properties and geometry, but maintaining its working concept based on a cam compression mechanism. Sensors and a display were added to improve the performance with a control algorithm for the rotation frequency and to show the ventilation curves over time to the medical staff. It was necessary to develop a mathematical model to relate the behavior between ventilation curves for a patient and physical variables of the design, especially in the epidemic COVID 19, that many countries are dealing with at the time research is being conducted. The mechanical ventilation system was redesigned, fabricated, and tested measuring its ventilation curves over time. Results indicate that this redesign provides a sturdy equipment able to work during a longer lifetime than the original. The replicability of the ventilation curves behavior is assured, while the mechanism dimensions are adapted for a particular airbag resuscitator. The mathematical model of the whole system can predict satisfactorily the ventilation curves over time and was used to provide the air pressure, volume, and flow as a function of the rotation angle measured by sensors.