In 2009, a new methodology for the continuous monitoring of E-modulus of cement-based materials since casting was proposed, under the designation EMM-ARM (E-modulus Measurement through Ambient Response Method). This methodology is a variant to classic resonant frequency methods that allows continuous stiffness monitoring from the instant of casting. After the encouraging results obtained in the first applications of EMM-ARM to cement pastes, the present paper gives continuity to previous developments, through validations with additional experimental methodologies and extension to thermal activation testing. At first, a comparison is performed between the results of EMM-ARM and those obtained through: pulse velocity methods (both ultrasonic contact probes and bender-extender elements), penetration resistance (Vicat needle) and cyclic compression on cylindrical specimens. Afterwards, the possibility of studying the activation energy of the stiffness evolution on tests conducted at 20°C and 40°C is explored.
1 February 2025 in e-Journal of Nondestructive Testing
The large-scale CT system GULLIVER was recently put into operation at the Rheinland-Pfälzische Technische Universität (RPTU) in Kaiserslautern (Germany). The project, which was launched in 2019 as a result of a competition between various German universities and research institutions, aims to use Computed Tomography (CT) to examine real-scale building components under the most realistic load conditions possible, as is customary in materials testing. The CT measurement is intended to provide new insights into the fatigue dynamics inside these concrete structures, which are up to 6 m long and 1 m wide, by detecting minimal cracks of up to 100 microns in size at the point of load application. The special design of the system and the components installed, open up completely new fields of application for high-energy CT that were previously not available. Particularly noteworthy is the system's gantry-type manipulation unit, whose use has so far been limited primarily to medical diagnostics, as well as the X-ray components used, which open up completely new fields of application for CT in terms of energy and resolution. But also, the processing of the resulting huge data of approx. 10,000 × 10,000 × 2,000 voxels generated in the system represents a particular challenge for the image processing and evaluation to be carried out following the measurement. In this publication, we present the project funded by the German Research Foundation (DFG) and its development containing the measurement results achieved during the current completion of the system as well as the status of the processing procedures developed. In addition, the future measurement campaigns planned with the system are presented and the possibilities to access the innovative testing system for own research activities are explained.
Carbon-reinforced concrete (CRC) is increasingly utilized in construction, due to its unique properties, such as corrosion resistance, high-tensile strength, and durability. Understanding its behavior under different loads is crucial to ensuring its safe and effective use in various construction applications. In this study, three-point bending tests were performed in combination with large-scale in situ computed tomography (CT). This paper presents the related three- and four-dimensional evaluation methods, with emphasis on crack width and quality control. The focus was on large CRC beams, with cross-sectional sizes of up to 80 mm by 160 mm. Such dimensions require extremely high energy during a CT scan. Therefore, a new experimental setup with energies of up to 8 MeV was used in this study. However, such high energies posed new challenges to the analysis methods. Therefore, two methods (digital volume correlation and grayscale profile analysis) for accurate crack width estimation were adapted and applied to the 3D reconstructions. In addition, a photogrammetric stereo image sequence was acquired and analyzed, using digital image correlation to cross-validate the results derived from the 3D crack width estimates. The 3D CT images also played a key role in the quality control measures, including the localization of the carbon-reinforcement and the assessment of porosity within the concrete structure.