Damir Duratbegović

Damir Duratbegović

Faculty of Dentistry with dental clinical center, University of Sarajevo, Sarajevo, Bosnia and Herzegovina, Federation of, Bosnia and Herzegovina
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2024 in Polymers
Verified
Journal Article
Open access
PDF file
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
NPNedim Pervan
Nedim Pervan
VJVedran Jakupović
Vedran Jakupović
SKSedin Kobašlija
Sedin Kobašlija
(1) Background: This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm2, LED 650 mW/cm2, LED 1100 mW/cm2), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene’s test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3) Results: Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm2/8 mm/20 s and 650 mW/cm2/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4) Conclusions: Suboptimal light intensity (<800 mW/cm2) can produce inadequate polymerization at the lower side of the composite layer when used from a distance. Prolonged irradiation can improve the polymerization to a certain extent. Clinicians are advised to monitor the intensity of the LCUs in order to optimize the photopolymerization process. Caution is required when polymerizing with high-intensity curing light in direct contact with the RBC with longer exposure times than recommended.

15 March 2023 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
EBElmedin Bajric
Elmedin Bajric
AAAmra Arslanagić
Amra Arslanagić
AZAmila Zukanović
Amila Zukanović
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
LŠLejla Šačić-Selmanović
Lejla Šačić-Selmanović
NMNina Marković
Nina Marković
Objectives: Dental caries first occurs within primary dentition in toddlers and preschool children, in a form of early childhood caries (ECC). In every day's busy and employment burdened parenting, care-takers and institutions have become important even more nowadays, not only for forming child gen-eral behavior and character, but also for maintenance of their general and oral health as well. Aims: To evaluate the presence and severity of ECC in children who attended public kindergartens in Sara-jevo, and to offer basic information for the maintenance and improvement of child oral health to their parents and kindergarten teachers. Methods: The study included 1722 preschool children aged 3-6 years who attended kindergartens within Sarajevo public kindergarten institution, together with their parents and kindergarten teachers. Dental team members gradually visited all kindergartens situated in four Sarajevo city municipalities and examined kindergarten children according to the WHO Oral Health Survey Manual. Oral health promotion material for parents and kindergarten teachers was al-so distributed simultaneously during sequential visits. Results: ECC was present in preschool kinder-garten children in Sarajevo, with its high prevalence (67.71%), dmft-value (3.97) and severity (SiC in-dex 8.79). There was also a significant lack of dental healthcare to examined children mostly related to lack of visiting dental offices by children's parents (CI=10.55%, RI=10.80%, TI=12.98%). Conclu-sion: Parental role in preserving and improving of their children oral health should be systematically and profoundly improved. Kindergarten officials and staff should recognize the importance of anticar-iogenic diet menus and oral hygiene maintenance within their institutions.

29 October 2025 in Polymers
Verified
Journal Article
Open access
PDF file
VJVedran Jakupović
Vedran Jakupović
NPNedim Pervan
Nedim Pervan
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
VJVedran Jakupovic
Vedran Jakupovic
Enis MuratovićEnis Muratović
Enis Muratović
SKSedin Kobašlija
Sedin Kobašlija
Background: The study investigates newly developed composite materials with advanced filler technology and modified resin matrices, designed to enhance esthetic quality, clinical efficiency, and mechanical properties. This study evaluated the effect of two light-curing protocols—a conventional low-voltage (LV) protocol (10 s at 1200 mW/cm2) and a high-voltage (HV) protocol (3 s at 3000 mW/cm2)—on the microhardness (MH), bottom/top MH ratio, and the correlation between filler content (wt%, vol%) and MH of bulk-fill resin-based composites (RBCs). Four RBCs were tested: Tetric PlusFill (TPF), Tetric Plus Flow(TPFW), Tetric PowerFill (PFL), and Tetric PowerFlow (PFW). Materials and Methods: Samples were fabricated in the laboratory using specially designed cylindrical molds (diameter = 8 mm, height = 4 mm). Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. Conclusions: The MH of bulk-fill RBCs was found to be influenced by both material composition and the applied light-curing protocol. An increase in filler content resulted in higher MH values under both protocols, with the filler volume fraction exhibiting a stronger correlation than the weight fraction. While both flowable and sculptable Tetric Plus composites exhibited higher MH values under the HV protocol, Tetric Power composites demonstrated greater initial hardness under LV protocol. The flowable composite PFW showed the most pronounced reduction in MH under HV curing. The bottom/top MH ratio exceeded 80% in all tested materials, confirming adequate polymerization throughout the composite layers.

1 January 2023 in Balkan Journal of Dental Medicine
Verified
Journal Article
Open access
PDF file
AZAmila Zukanović
Amila Zukanović
EBElmedin Bajrić
Elmedin Bajrić
NMNina Marković
Nina Marković
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
EKElma Katana
Elma Katana
HPHasan Pejak
Hasan Pejak
Background/Aim: Deep carious lesions on primary teeth usually have been causing infectious dental pulp changes. If indicated, traditional endodontic root canal treatment for these kinds of pulpal infections in primary teeth usually should involve the performing of pulpectomy methods, but often with questionable prognosis. The lesion sterilization and tissue repair (LSTR) approach is one of the good endodontic therapeutic alternatives for affected primary teeth with a poor prognosis, which could otherwise be condemned to premature extraction. Aim was to evaluate the medium-term clinical success in everyday practice of the LSTR method applied in affected primary teeth with irreversible pulpal tissue infections by observation of reduction/absence of their clinical symptoms. Material and methods: The study sample included child patients who had one or more of their affected primary molars with irreversible pulpal tissue changes of poor prognosis treated with the LSTR method. For each patient whose primary molar tooth was endodontically treated with the LSTR method a clinical evaluation of treated tooth was performed at intervals of 1 and 12 months afterwards. Results: Study sample was consisted of 40 child patients aged 4 to 9 years, with 45 primary molars included in total. It was obvious that the symptoms related to affected sample teeth have already been decreased almost immediately after initial action of triple antibiotic paste. Final outcome after 12-months follow-up period was success of applied LSTR method in 43 (95.6%) affected sample teeth in a way that initial clinical symptoms completely decreased and disappeared. Conclusions: LSTR method has been shown as successful pulpotomy technique for noninstrumental endodontic approach in non-vital pulp treatment of primary molar teeth in a 12-months follow-up period.

1 January 2023 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
NHNaida Hadziabdic
Naida Hadziabdic
ABAmila Balic
Amila Balic
ECEmina Cengic
Emina Cengic
EKElma Katana
Elma Katana
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
ESEdina Lazovic Salcin
Edina Lazovic Salcin
This study presents a case report of an inflammatory dentigerous cyst of tooth #35, associated with its previously endodontically treated deciduous predecessor. Cystic lesion growth caused impaction of the second premolar, displacing it closer to the lower border of the mandible. The lesion represents a typical dentigerous cyst that possibly arises in association with periapical inflammation of a deciduous molar involving the follicle of the premolars. This report highlights the inflammatory etiology of dentigerous cysts, which mainly occur in mixed dentition. A 12‐year‐old patient was referred to Oral Surgery Department regarding a sizeable radiolucent lesion in the unerupted mandibular second premolar region, detected on an Orthopantomagram (OPG) X‐ray. A non‐vital primary predecessor had been endodontically treated at least one year before an examination, with a control OPG X‐ray showing no signs of pathology at the time. The patient did not report any symptoms. Clinical examination revealed an egg‐like tumefaction of the alveolar bone in the left premolar region of the mandible. Cone‐beam computed tomography analysis showed a sizeable translucent lesion surrounding the crown of the impacted tooth. The lesion was enucleated in its entirety, along with the impacted premolar, under local anesthesia. Clinical findings combined with radiographic and microscopic examinations confirmed the diagnosis of an inflammatory dentigerous cyst. The seventeen month follow‐up revealed good bone healing. This case presented a rare complication of endodontic treatment of deciduous teeth and informed on possible complications of endodontic therapy in deciduous teeth, emphasizing the importance of early diagnosis of cysts in preventing extraction of permanent teeth.

1 January 2024 in Balkan Journal of Dental Medicine
Verified
Journal Article
Open access
PDF file
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
SKSedin Kobašlija
Sedin Kobašlija
NPNedim Pervan
Nedim Pervan
DHDamir Hodžić
Damir Hodžić
EKElma Katana
Elma Katana
SJSenka Jakupović
Senka Jakupović
Background/Aim: To evaluate the effect of curing light parameters (intensity, duration, and distance of curing tip) on the depth of cure of conventional resin-based composite. Material and methods: Cylindrical specimens made of nanohybride resin-based composite are cured with 12 different curing protocols, combined with 3 different light intensities (300, 650, and 1100 mW/cm²), 2 distances of curing tip (0 and 8 mm), and 2 exposure times (20 and 40 seconds). The specimens were measured after scraping the uncured composite material according to the ISO 4049 standard. The depth of cure was calculated by dividing the length of the remaining composite by 2. Data were analyzed using: Levene's test and Multivariate Analysis-of-variance (MANOVA). The level of significance was set at P<0.05. Results: The highest depth of cure (3.332 mm) was observed for curing protocol 1100mW/cm²/0mm/40s. The lowest depth of cure had specimens cured with curing protocol 300 mW/cm²/8mm/20s (2.034mm). MANOVA showed a significant influence of the distance of the curing tip (P=0.014; P=0.001) regardless of light intensity and duration of exposure time. Exposure time was a significant factor (P=0.009) when cured from different distances. Although higher light intensity produced a higher depth of cure, light intensity was not a significant factor. Conclusions: The depth of cure can be increased by reducing the distance of the curing tip, when it is possible. At a distance of 8 mm, the depth of cure can be increased by a longer exposure time, regardless of curing light intensity.