Vedran Jakupović

Prof. Dr. Vedran Jakupović

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
VJVedran Jakupović
Vedran Jakupović
IAIvica Anić
Ivica Anić
MAMuhamed Ajanović
Muhamed Ajanović
SKSamra Korać
Samra Korać
AKAlma Konjhodžić
Alma Konjhodžić
AVAmra Vuković
Amra Vuković
Objective: The present study aims to investigate the influence of presence and shape of cervical lesions on biomechanical behavior of mandibular first premolar, subjected to two types of occlusal loading using three-dimensional (3D) finite element method (FEM). Materials and Methods: 3D models of the mandibular premolar are created from a micro computed tomography X-ray image: model of sound mandibular premolar, model with the wedge-shaped cervical lesion (V lesion), and model with saucer-shaped cervical lesion (U lesion). By FEM, straining of the tooth tissues under functional and nonfunctional occlusal loading of 200 (N) is analyzed. For the analysis, the following software was used: CTAn program 1.10 and ANSYS Workbench (version 14.0). The results are presented in von Mises stress. Results: Values of calculated stress in all tooth structures are higher under nonfunctional occlusal loading, while the functional loading is resulted in homogeneous stress distribution. Nonfunctional load in the cervical area of sound tooth model as well as in the sub-superficial layer of the enamel resulted with a significant stress (over 50 [MPa]). The highest stress concentration on models with lesions is noticed on the apex of the V-shaped lesion, while stress in saucer U lesion is significantly lower and distributed over wider area. Conclusion: The type of the occlusal teeth loading has the biggest influence on cervical stress intensity. Geometric shape of the existing lesion is very important in the distribution of internal stress. Compared to the U-shaped lesions, V-shaped lesions show significantly higher stress concentrations under load. Exposure to stress would lead to its progression.

10 May 2023 in Polymers
Verified
Journal Article
Open access
PDF file
VJVedran Jakupović
Vedran Jakupović
NPNedim Pervan
Nedim Pervan
EMElmedin Mešić
Elmedin Mešić
AGAlma Gavranović-Glamoč
Alma Gavranović-Glamoč
ABAnita Bajsman
Anita Bajsman
AKAlma Kantardžić-Kovačević
Alma Kantardžić-Kovačević
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm2) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm2) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.

1 January 2014 in Acta Informatica Medica
Verified
Journal Article
Open access
VJVedran Jakupović
Vedran Jakupović
ECEdin Cerjakovic
Edin Cerjakovic
ATAlan Topcic
Alan Topcic
MAMuhamed Ajanovic
Muhamed Ajanovic
AKAlma KonjhodzicPrcic
Alma KonjhodzicPrcic
AVAmra Vukovic
Amra Vukovic
An abfraction lesion is a type of a non-carious cervical lesion (NCCL) that represents a sharp defect on the cervical part of tooth, caused by occlusal biomechanical forces. The largest prevalence of the NCCL is found on the mandibular first premolar. The goal of the study is, by means of a numerical method - the finite element method (FEM), in an appropriate computer program, conduct a stress analysis of the mandibular premolar under various static loads, with a special reference to the biomechanics of cervical tooth region. A three-dimensional model of the mandibular premolar is gained from a µCT x-ray image. By using the FEM, straining of the enamel, dentin, peridontal ligament and alveolar bone under axial and paraxial forces of 200 [N] is analyzed. The following software were used in the analysis: CT images processing-CTAn program and FEM analysis-AnsysWorkbench 14.0. According to results obtained through the FEM method, the calculated stress is higher with eccentric forces within all tested tooth tissue. The occlusal load leads to a significant stress in the cervical tooth area, especially in the sub-superficial layer of the enamel (over 50 MPa). The measured stress in the peridontal ligament is approximately three times higher under paraxial load with regard to the axial load, while stress calculated in the alveolar bone under paraxial load is almost ten times higher with regard to the axial load. The highest stress values were calculated in the cervical part of the alveoli, where bone resorption is most commonly seen. Action of occlusal forces, especially paraxial ones, leads to significant stress in the cervical part of tooth. The stress values in the cervical sub-superficial enamel layer are almost 5 times higher in relation to the superficial enamel, which additionally confirms complexity of biomechanical processes in the creation of abfraction lesions.

14 November 2024 in Polymers
Verified
Journal Article
Open access
PDF file
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
NPNedim Pervan
Nedim Pervan
VJVedran Jakupović
Vedran Jakupović
SKSedin Kobašlija
Sedin Kobašlija
(1) Background: This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm2, LED 650 mW/cm2, LED 1100 mW/cm2), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene’s test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3) Results: Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm2/8 mm/20 s and 650 mW/cm2/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4) Conclusions: Suboptimal light intensity (<800 mW/cm2) can produce inadequate polymerization at the lower side of the composite layer when used from a distance. Prolonged irradiation can improve the polymerization to a certain extent. Clinicians are advised to monitor the intensity of the LCUs in order to optimize the photopolymerization process. Caution is required when polymerizing with high-intensity curing light in direct contact with the RBC with longer exposure times than recommended.

29 October 2025 in Polymers
Verified
Journal Article
Open access
PDF file
VJVedran Jakupović
Vedran Jakupović
NPNedim Pervan
Nedim Pervan
Damir DuratbegovićDamir Duratbegović
Damir Duratbegović
VJVedran Jakupovic
Vedran Jakupovic
Enis MuratovićEnis Muratović
Enis Muratović
SKSedin Kobašlija
Sedin Kobašlija
Background: The study investigates newly developed composite materials with advanced filler technology and modified resin matrices, designed to enhance esthetic quality, clinical efficiency, and mechanical properties. This study evaluated the effect of two light-curing protocols—a conventional low-voltage (LV) protocol (10 s at 1200 mW/cm2) and a high-voltage (HV) protocol (3 s at 3000 mW/cm2)—on the microhardness (MH), bottom/top MH ratio, and the correlation between filler content (wt%, vol%) and MH of bulk-fill resin-based composites (RBCs). Four RBCs were tested: Tetric PlusFill (TPF), Tetric Plus Flow(TPFW), Tetric PowerFill (PFL), and Tetric PowerFlow (PFW). Materials and Methods: Samples were fabricated in the laboratory using specially designed cylindrical molds (diameter = 8 mm, height = 4 mm). Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. Conclusions: The MH of bulk-fill RBCs was found to be influenced by both material composition and the applied light-curing protocol. An increase in filler content resulted in higher MH values under both protocols, with the filler volume fraction exhibiting a stronger correlation than the weight fraction. While both flowable and sculptable Tetric Plus composites exhibited higher MH values under the HV protocol, Tetric Power composites demonstrated greater initial hardness under LV protocol. The flowable composite PFW showed the most pronounced reduction in MH under HV curing. The bottom/top MH ratio exceeded 80% in all tested materials, confirming adequate polymerization throughout the composite layers.

1 January 2017 in Medical Archives
Verified
Journal Article
Open access
VJVedran Jakupović
Vedran Jakupović
AKAlma Konjhodzic
Alma Konjhodzic
LBLajla Brankovic
Lajla Brankovic
SKSamra Korac
Samra Korac
ITIrmina Tahmiscija
Irmina Tahmiscija
AGAlma Glamoc
Alma Glamoc
The aim of this study was to compare time of preparation and canal aberrations in a simulated root canals after using three different rotary systems: Endostar E5, Endostar E3 and T One File Gold. A total of 90 endodontic training blocks were used in this study and divided into three groups consisting of 30 each (n = 30). Blocks processing was performed by thirty dentists without any prior experience in rotary instrumentation techniques. In the first group blocks were prepared using Endostar E5, in second one with Endostar E3 and in third one with T One File Gold system. The preparation time was measured. The postoperative image of each block was taken by stereomicroscope and canal aberrations (ledge and instrument fracture) was recorded. Statistical analysis was done by SPSS software. Instrumentation with T One File Gold system is significantly faster compared to instrumentation with Endostar E5 and Endostar E3 systems (p <0.05). There are no statistically significant differences in the type and number of procedural errors between Endostar E5, Endostar E3 and T One File Gold systems when the operators have no previous experience in rotary instrumentation techniques. Under the conditions of this study, the incidence of examined canal aberrations were similar for all tested systems. The preparation time was significantly shorter with single file system.