The design of the Moderate-Resolution Imaging Spectroradiometer (MODIS) instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (~ 1 km) with comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSBs) with wavelengths from 0.41 to 2.2 μm collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the SD stability monitor (SDSM) provides a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudoinvariant desert sites are used to characterize the response versus scan-angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges, and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror-side-dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared with Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during postlaunch operations. As the instruments age and continue to endure the space environment, the detectors and the optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.
17 September 2013 in IEEE Transactions on Geoscience and Remote Sensing
The high-contrast edge of the Moon has been used for the on-orbit measurement of the modulation transfer function (MTF) of remote sensing instruments with a lunar observation capability. With the lunar edge as a target, the classical edge method is applied to the National Aeronautics and Space Administration's MODerate resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua satellites. One of the major difficulties encountered during the calculation is that the spatial resolution of MODIS is too coarse to capture the fine structure of the edge spread function (ESF), which is required to calculate the MTF. To produce the MODIS ESF in high resolution, lunar images of a selected edge acquired by multiple instrument scans need to be superposed by aligning the edge positions accurately. In this paper, an algorithm is developed to perform the alignment, based on the lunar position data generated by the MODIS geolocation algorithm and recorded scan by scan. The positions of the lunar edges at the focal plane are calculated scan by scan, allowing the construction of a high-quality ESF for MTF derivation. The algorithm is applied to all MODIS bands with 250-m, 500-m, and 1-km spatial resolutions in both along-scan and along-track directions. The along-track MTF results are particularly valuable because the onboard SpectroRadiometric Calibration Assembly can only monitor the along-scan MTF. The trending results show that the along-track MTF of MODIS has been stable throughout the MODIS lifetime and is well above the design specification for all bands. The limitation of the algorithm is analyzed. The algorithm developed in this paper can be applied to other instruments with similar design features.
<!-- *** Custom HTML *** --> The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.
<!-- *** Custom HTML *** --> Since its launch in December 1999, Terra Moderate Resolution Imaging Spectroradiometer (MODIS) has successfully operated for more than 20 years, with its observations generating a broad range of science data products that have greatly enabled the remote sensing community and users worldwide in their studies of many key geophysical parameters of the Earth’s systems. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, which are calibrated by a set of onboard calibrators (OBCs). Also contributing to the sensor’s mission-long on-orbit calibration and characterization are near-monthly scheduled lunar observations and multiple time series of the sensor’s responses over select ground targets at a variety of scan angles. To a large extent, the quality of MODIS data products relies strongly on the dedicated efforts to operate and calibrate the instrument, to derive and update calibration parameters, and to develop and implement new calibration strategies and algorithms in response to on-orbit changes of the sensor’s characteristics and its OBC functions. We provide an overview of the Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve the instrument and OBC functions and their operation strategies. It also illustrates the sensor’s on-orbit performance with results derived from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms as well as calibration lookup table updates. To date, the Terra MODIS instrument and its OBCs continue to operate and function normally. Except for those identified prelaunch, most spectral bands and detectors continue to meet their specified calibration requirements. Also discussed in our paper are lessons learned from Terra MODIS operation and calibration, as well as future efforts to further extend and maintain the quality of its long-term data records.
Since its launch in May, 2002, Aqua MODIS has successfully operated for more than 20 years and has continuously generated a wide range of data products that have enabled and supported the remote sensing community and users worldwide for their studies of the Earth’s system by monitoring changes in its key environmental parameters. Although Aqua MODIS, designed with a lifetime requirement of 6 years, is currently operated in its extended mission phase, it continues to make high quality global observations of the Earth’s surface via its 36 spectral bands that cover wavelengths from visible to long-wave infrared. To date, all instrument on-board calibrators (OBC) remain capable of performing their design functions, providing various calibration data sets to help monitor on-orbit changes in sensor responses and performance characteristics. In addition to the OBC, regularly scheduled lunar observations and select Earth-view targets are used extensively to support sensor on-orbit calibration, especially for the calibration of the visible channels (or bands). We provide an overview of Aqua MODIS on-orbit calibration activities and methodologies for both reflective solar bands and thermal emissive bands, illustrate its on-orbit performance over the past 20 years using examples derived from OBC measurements, lunar observations, and Earth-view response trends, and describe various calibration improvements made over its entire mission. We focus on key issues identified since launch, such as solar diffuser degradation, electronic crosstalk, and on-orbit changes in sensor response versus scan-angle, along with approaches and strategies developed to mitigate their impact on sensor calibration quality. Also discussed in this paper are some of the key calibration enhancements incorporated recently in the Collection 6.1 and the upcoming Collection 7 Level-1B algorithms.
Satellite imagery and data are playing an increasingly important role in scientific studies of the Earth and its climate. The scientific community has been demanding ever-increasing capabilities and accuracy from the data provided by these satellites. One key instrument on board a series of satellite platforms is the Visible Infrared Imaging Radiometer Suite (VIIRS), which provides high-quality data of the Earth from low Earth orbit covering the visible to long-wave infrared parts of the spectrum. The fourth build in the series, set to be launched on the Joint Polar-orbiting Satellite System 3 (JPSS-3) platform, has recently completed its main ground calibration program and is set to be integrated into the satellite bus in the near future. This calibration program covered a comprehensive series of performance metrics designed to demonstrate the quality of the science data and ensure the instrument can maintain its calibration successfully once on-orbit. The subject of this work covers the radiometric calibration metrics including dynamic range, signal-to-noise ratio/noise equivalent differential temperature (SNR/NEdT), polarization sensitivity, scattered light response, relative spectral response, response versus scan angle, and uniformity, as well as uncertainties; all key metrics met or exceeded their design requirements with some minor exceptions. Comparisons to previous builds will also be provided.