Dan Cosmin Serbanoiu

Dr. Dan Cosmin Serbanoiu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
AVAurel-Claudiu Vartolomei
Aurel-Claudiu Vartolomei
Dan Cosmin SerbanoiuDan Cosmin Serbanoiu
Dan Cosmin Serbanoiu
DGDana Valentina Ghiga
Dana Valentina Ghiga
MMMarioara Moldovan
Marioara Moldovan
Stanca CucStanca Cuc
Stanca Cuc
MPMariana Pacurar
Mariana Pacurar
Friction is an intensely studied feature in orthodontics, as the sliding mechanics approach remains one of the most utilized techniques in current practice, and the question of whether self-ligating brackets produce less friction than conventional brackets still stands. The objective of this study was to compare a self-ligating system with different closing mechanisms and a conventional system with different ligating mechanisms regarding their frictional properties. Laboratory measurements were performed using an advanced materials testing machine generating tensile strength and load at maximum Load values, which were statistically analyzed and compared. These two parameters have been associated with the frictional resistance generated at the archwire–bracket slot interface. Statistically significant results were obtained when comparing the active self-ligating brackets with the passive self-ligating (tensile strength mean 1.953, SD 0.4231; load at maximum moad mean 6.000, SD 1.3000) and conventional brackets (tensile strength mean 1.953, SD 0.4231; load at maximum load mean 6.000, SD 1.3000), as well as when comparing the passive self-ligating brackets with the conventional brackets (tensile strength mean 1.708, SD 0.8628; load at maximum load mean 5.254, SD 2.645). The active self-ligating brackets tended to produce more friction when compared to the passive self-ligating brackets but were similar to conventional brackets with stainless steel ligatures.

20 May 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
Dan Cosmin SerbanoiuDan Cosmin Serbanoiu
Dan Cosmin Serbanoiu
AVAurel-Claudiu Vartolomei
Aurel-Claudiu Vartolomei
DGDana Valentina Ghiga
Dana Valentina Ghiga
SPSilvia Izabella Pop
Silvia Izabella Pop
IPirinel panainte
irinel panainte
MPMariana Pacurar
Mariana Pacurar
Interproximal enamel reduction, also known as stripping, is a common orthodontic procedure that reduces the mesiodistal diameter of teeth, allowing for a balance of available space in dental arches. The aim of this study was to assess the enamel surface microhardness resulting from the application of currently available methods for interproximal reduction. Forty-two extracted human permanent teeth were divided into six different groups, each subjected to a therapeutic stripping procedure using various methods (i.e., diamond burs, abrasive strips of 90 μm, 60 μm, 40 μm, and 15 μm, and abrasive discs). Stripping was performed by a single individual in accordance with the manufacturers’ recommendations for the various systems used. One of the proximal faces of the tooth underwent IPR, while the other side remained untreated for control. The hardness of the enamel surface was measured using a Vickers hardness tester. The control group achieved the hardest enamel surface (354.4 ± 41.02 HV1), while the lowest was observed for enamel surfaces treated with 90 µm abrasive strips (213.7 ± 118.6). The only statistically significant difference was identified in comparisons between the values measured for the control group and those obtained after stripping with diamond burs (p = 0.0159). Enamel microhardness varied depending on the stripping instrument used, but no statistically significant differences were found (p > 0.05). Optimal microhardness values, close to those of healthy enamel, were achieved after mechanical treatment with 15 µm abrasive strips and abrasive discs. Dental stripping is a safe therapeutic procedure that has a relatively minor influence on the microhardness of surface enamel.

23 July 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
Dan Cosmin SerbanoiuDan Cosmin Serbanoiu
Dan Cosmin Serbanoiu
AVAurel-Claudiu Vartolomei
Aurel-Claudiu Vartolomei
DGDana Valentina Ghiga
Dana Valentina Ghiga
MMMarioara Moldovan
Marioara Moldovan
CODRUTA SAROSICODRUTA SAROSI
CODRUTA SAROSI
MPMariana Pacurar
Mariana Pacurar
Interproximal enamel reduction (IER) is a minimally invasive therapeutic procedure commonly used in orthodontics to address both functional and aesthetic issues. Its mechanical effects on enamel surfaces induce the formation of grooves, furrows, scratches, depressions, and valleys. The aim of this study was to assess the enamel surface roughness resulting after the application of currently available methods for interproximal reduction. Ninety freshly extracted human teeth were divided into six groups and subjected to the stripping procedure, using a different method for each group (diamond burs, abrasive strips of 90 μm, 60 μm, 40 μm, 15 μm, and abrasive discs). A single individual performed stripping according to the manufacturer’s recommendations, involving interproximal reduction on one tooth’s proximal face and leaving the other side untreated. Qualitative and quantitative assessment of the enamel surfaces was carried out using Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM), obtaining 2D and volumetric 3D images of the enamel surface microstructure and nanostructure. The study found that diamond burs and abrasive strips of 60 μm and 90 μm increased enamel roughness due to intense de-structuring effects, while the 40 μm polisher had a gentler effect and 15 μm abrasive strips and polishing discs preserved enamel surface quality and removed natural wear traces.

21 October 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AVAurel-Claudiu Vartolomei
Aurel-Claudiu Vartolomei
DGDana Valentina Ghiga
Dana Valentina Ghiga
Dan Cosmin SerbanoiuDan Cosmin Serbanoiu
Dan Cosmin Serbanoiu
MMMarioara Moldovan
Marioara Moldovan
Stanca CucStanca Cuc
Stanca Cuc
MPMaria Cristina Figueiredo Pollmann
Maria Cristina Figueiredo Pollmann
Adhesion remains a key element in dentistry, whether approached in prosthetics, odontology, or orthodontics. It is a continuously researched aspect, as improved materials and adhesive methods keep emerging in the market. No orthodontic treatment can be effective without the proper adhesion strength of the bonded elements on the teeth. The objective of this research, in the broad context of self-ligating versus conventional brackets, was to compare active and passive self-ligating systems with a conventional one by conducting an in vitro study on human-extracted premolars. Shear bond strength tests were executed by means of an advanced materials-testing machine that generated maximum load and tensile strength values. The data obtained underwent statistical analysis with a statistical threshold of p < 0.05. The results regarding the statistical significance were acquired when comparing the passive self-ligating system with the active self-ligating and conventional systems (load-at-maximum-load mean 204.9, SD 91.09, and p < 0.05). In this study, the passive self-ligating bracket system appears to present increased shear bond strength.

23 March 2022 in Medicina
Verified
Journal Article
Open access
PDF file
IPirinel panainte
irinel panainte
DNDorin-Horațiu Nenovici
Dorin-Horațiu Nenovici
MMMarius Maris
Marius Maris
Dan Cosmin SerbanoiuDan Cosmin Serbanoiu
Dan Cosmin Serbanoiu
CVClaudiu Vartolomei
Claudiu Vartolomei
MPMariana Pacurar
Mariana Pacurar
Background and Objectives: Corticotomy-facilitated orthodontics is an approach that can be useful in treating complex orthodontic cases and that could enhance the rate of tooth movement. The aim of this study was to evaluate the changes that occurred in the buccal cortical bone and at the root level after an orthodontic treatment when corticotomy was used, in Romanian patients. Materials and Methods: After dividing the subjects into two groups (maxillary and mandibular corticotomy), based on CBCT, measurements were made of the thickness of the cortical buccal bone at the cervical, median and apical level, and of the root length at T0 (before corticotomy) and T1 (6 months after surgery). Several tests were used for statistical analysis of the data. Results: In the maxillary arch, the bone thickness measured after corticotomy in males was 0.64 mm at the cervical level, 0.53 mm at the medial level and 0.30 mm in the apical area. In females, the values were 0.46 mm (cervical), 0.37 mm (medial) and 0.36 mm (apical). In the lower arch, the values obtained for these three regions were 0.37 mm, 0.30 mm and 0.37 mm for males and 0.58 mm, 0.32 mm and 0.43 mm for female subjects. All values were statistically significant. The root length for the lower teeth at T0 was 11.98 ± 2.24 mm at T0 and 11.97 ± 2.24 mm at T1. For the upper teeth, the root length at T0 was 13.83 ± 2.28 mm and 13.81 ± 2.28 mm. Conclusions: Comparing the measurements, it was observed that the biggest changes in the cortical bone were at the cervical level. In the maxillary arch, the most significant modifications were registered at the canines and the level of the first premolars, and in the lower arch at the incisors level. The measured root resorption of the teeth was considered to be statistically insignificant.