Representative Publications

View All Publications
22 June 2023 in Cancers
Verified
Journal Article
Open access
PDF file
XHXinyue Huang
Xinyue Huang
Hamed HooshangnejadHamed Hooshangnejad
Hamed Hooshangnejad
Debarghya ChinaDebarghya China
Debarghya China
ZFZiwei Feng
Ziwei Feng
JLJunghoon Lee
Junghoon Lee
Kai DingKai Ding
Kai Ding
Pancreatic cancer with less than 10% 3-year survival rate is one of deadliest cancer types and greatly benefits from enhanced radiotherapy. Organ motion monitoring helps spare the normal tissue from high radiation and, in turn, enables the dose escalation to the target that has been shown to improve the effectiveness of RT by doubling and tripling post-RT survival rate. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. We proposed a novel shape estimation for flexible array transducer using two sequential algorithms: (i) an optical tracking-based system that uses the optical markers coordinates attached to the probe at specific positions to estimate the array shape in real-time and (ii) a fully automatic shape optimization algorithm that automatically searches for the optimal array shape that results in the highest quality reconstructed image. We conducted phantom and in vivo experiments to evaluate the estimated array shapes and the accuracy of reconstructed US images. The proposed method reconstructed US images with low full-width-at-half-maximum (FWHM) of the point scatters, correct aspect ratio of the cyst, and high-matching score with the ground truth. Our results demonstrated that the proposed methods reconstruct high-quality ultrasound images with significantly less defocusing and distortion compared with those without any correction. Specifically, the automatic optimization method reduced the array shape estimation error to less than half-wavelength of transmitted wave, resulting in a high-quality reconstructed image.

4 December 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Debarghya ChinaDebarghya China
Debarghya China
ZFZiwei Feng
Ziwei Feng
Hamed HooshangnejadHamed Hooshangnejad
Hamed Hooshangnejad
DSDaniel Sforza
Daniel Sforza
PVPrasad Vagdargi
Prasad Vagdargi
Kai DingKai Ding
Kai Ding
Flexible array transducers can adapt to patient-specific geometries during real-time ultrasound (US) image-guided therapy monitoring. This makes the system radiation-free and less user-dependency. Accurately estimating the geometry of flexible transducers is crucial for the delay-and-sum (DAS) beamforming algorithm to reconstruct B-mode US images. The primary innovation of this research is to build a system named FLexible transducer with EXternal tracking (FLEX) to estimate the position of each element of the flexible transducer and reconstruct US images. Customized optical markers and a tracker were used to track the probe geometry. The coordinate position and azimuth angle of each element were estimated from the polygon fitting algorithm. Subsequently, traditional DAS was employed to estimate the delay from the tracked element position and reconstruct the US image from radio-frequency (RF) channel data. The proposed method was evaluated on both phantoms and cadaveric specimens to show its feasibility in clinical applications. The deviations of the tracked probe geometry by the proposed system compared to the ground truth system were measured to be 0.50±0.29 mm for the CIRS phantom, 0.54±0.35 mm for the deformable phantom, and 0.36±0.24 mm on the cadaveric specimen. We compared the target structure in the reconstructed US image generated using the untracked and tracked probe geometry. The Dice score of the reconstructed target structure of the CIRS phantom with untracked and tracked probe geometry was 62.3±9.2% and 95.1±3.3% respectively. The proposed method achieved high accuracy (<0.5 mm error) in tracking the element position for various random curvatures applicable for clinical deployment. The evaluation results show that the radiation-free proposed method can effectively reconstruct US images and assist in monitoring image-guided therapy with minimal user dependency.

1 April 2019
Verified
Conference Paper
Open access
Debarghya ChinaDebarghya China
Debarghya China
FTFrancis Tom
Francis Tom
SNSumanth Nandamuri
Sumanth Nandamuri
AKAupendu Kar
Aupendu Kar
MSMukundhan Srinivasan
Mukundhan Srinivasan
DSDebdoot Sheet
Debdoot Sheet

20 March 2024 in Cancers
Verified
Journal Article
Open access
PDF file
Michele MoreauMichele Moreau
Michele Moreau
LKLensa S. Keno
Lensa S. Keno
Debarghya ChinaDebarghya China
Debarghya China
SMSerena Mao
Serena Mao
SAShahinur Acter
Shahinur Acter
WNWilfred Ngwa
Wilfred Ngwa
Globally, cervical cancer is the fourth leading cancer among women and is dominant in resource-poor settings in its occurrence and mortality. This study focuses on developing liquid immunogenic fiducial eluter (LIFE) Biomaterial with components that include biodegradable polymers, nanoparticles, and an immunoadjuvant. LIFE Biomaterial is designed to provide image guidance during radiotherapy similar to clinically used liquid fiducials while enhancing therapeutic efficacy for advanced cervical cancer. C57BL6 mice were used to grow subcutaneous tumors on bilateral flanks. The tumor on one flank was then treated using LIFE Biomaterial prepared with the immunoadjuvant anti-CD40, with/without radiotherapy at 6 Gy. Computed tomography (CT) and magnetic resonance (MR) imaging visibility were also evaluated in human cadavers. A pharmacodynamics study was also conducted to assess the safety of LIFE Biomaterial in healthy C57BL6 female mice. Results showed that LIFE Biomaterial could provide both CT and MR imaging contrast over time. Inhibition in tumor growth and prolonged significant survival (* p < 0.05) were consistently observed for groups treated with the combination of radiotherapy and LIFE Biomaterial, highlighting the potential for this strategy. Minimal toxicity was observed for healthy mice treated with LIFE Biomaterial with/without anti-CD40 in comparison to non-treated cohorts. The results demonstrate promise for the further development and clinical translation of this approach to enhance the survival and quality of life of patients with advanced cervical cancer.

11 April 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Hamed HooshangnejadHamed Hooshangnejad
Hamed Hooshangnejad
Debarghya ChinaDebarghya China
Debarghya China
YHYixuan Huang
Yixuan Huang
WZWojciech Zbijewski
Wojciech Zbijewski
AUAli Uneri
Ali Uneri
Kai DingKai Ding
Kai Ding
Image-guided interventional oncology procedures can greatly enhance the outcome of cancer treatment. As an enhancing procedure, oncology smart material delivery can increase cancer therapy’s quality, effectiveness, and safety. However, the effectiveness of enhancing procedures highly depends on the accuracy of smart material placement procedures. Inaccurate placement of smart materials can lead to adverse side effects and health hazards. Image guidance can considerably improve the safety and robustness of smart material delivery. In this study, we developed a novel generative deep-learning platform that highly prioritizes clinical practicality and provides the most informative intra-operative feedback for image-guided smart material delivery. XIOSIS generates a patient-specific 3D volumetric computed tomography (CT) from three intraoperative radiographs (X-ray images) acquired by a mobile C-arm during the operation. As the first of its kind, XIOSIS (i) synthesizes the CT from small field-of-view radiographs;(ii) reconstructs the intra-operative spacer distribution; (iii) is robust; and (iv) is equipped with a novel soft-contrast cost function. To demonstrate the effectiveness of XIOSIS in providing intra-operative image guidance, we applied XIOSIS to the duodenal hydrogel spacer placement procedure. We evaluated XIOSIS performance in an image-guided virtual spacer placement and actual spacer placement in two cadaver specimens. XIOSIS showed a clinically acceptable performance, reconstructed the 3D intra-operative hydrogel spacer distribution with an average structural similarity of 0.88 and Dice coefficient of 0.63 and with less than 1 cm difference in spacer location relative to the spinal cord.

21 October 2017
Verified
Book Chapter
Open access
PDF file
Debarghya ChinaDebarghya China
Debarghya China
PMPabitra Mitra
Pabitra Mitra
DSDebdoot Sheet
Debdoot Sheet
Coronary artery disease accounts for a large number of deaths across the world and clinicians generally prefer using x-ray computed tomography or magnetic resonance imaging for localizing vascular pathologies. Interventional imaging modalities like intravascular ultrasound (IVUS) are used to adjunct diagnosis of atherosclerotic plaques in vessels, and help assess morphological state of the vessel and plaque, which play a significant role for treatment planning. Since speckle intensity in IVUS images are inherently stochastic in nature and challenge clinicians with accurate visibility of the vessel wall boundaries, it requires automation. In this paper we present a method for segmenting the lumen and external elastic laminae of the artery wall in IVUS images using random walks over a multiscale pyramid of Gaussian decomposed frames. The seeds for the random walker are initialized by supervised learning of ultrasonic backscattering and attenuation statistical mechanics from labelled training samples. We have experimentally evaluated the performance using 77 IVUS images acquired at 40 MHz that are available in the IVUS segmentation challenge dataset ( http://www.cvc.uab.es/IVUSchallenge2011/dataset.html .) to obtain a Jaccard score of \(0.89 \pm 0.14\) for lumen and \(0.85 \pm 0.12\) for external elastic laminae segmentation over a 10-fold cross-validation study.