Deshan Kalupahana

Mr. Deshan Kalupahana

School of Computer Science and Engineering, The University of New South Wales, Sydney, New South Wales, Australia
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SVSahan M. Vijithananda
Sahan M. Vijithananda
MJMohan Mohan L. Jayatilake
Mohan Mohan L. Jayatilake
BHBadra Hewavithana
Badra Hewavithana
Teresa GonçalvesTeresa Gonçalves
Teresa Gonçalves
Luis RatoLuis Rato
Luis Rato
KDKaruna D. Dissanayake
Karuna D. Dissanayake
Background: Diffusion-weighted (DW) imaging is a well-recognized magnetic resonance imaging (MRI) technique that is being routinely used in brain examinations in modern clinical radiology practices. This study focuses on extracting demographic and texture features from MRI Apparent Diffusion Coefficient (ADC) images of human brain tumors, identifying the distribution patterns of each feature and applying Machine Learning (ML) techniques to differentiate malignant from benign brain tumors. Methods: This prospective study was carried out using 1599 labeled MRI brain ADC image slices, 995 malignant, 604 benign from 195 patients who were radiologically diagnosed and histopathologically confirmed as brain tumor patients. The demographics, mean pixel values, skewness, kurtosis, features of Grey Level Co-occurrence Matrix (GLCM), mean, variance, energy, entropy, contrast, homogeneity, correlation, prominence and shade, were extracted from MRI ADC images of each patient. At the feature selection phase, the validity of the extracted features were measured using ANOVA f-test. Then, these features were used as input to several Machine Learning classification algorithms and the respective models were assessed. Results: According to the results of ANOVA f-test feature selection process, two attributes: skewness (3.34) and GLCM homogeneity (3.45) scored the lowest ANOVA f-test scores. Therefore, both features were excluded in continuation of the experiment. From the different tested ML algorithms, the Random Forest classifier was chosen to build the final ML model, since it presented the highest accuracy. The final model was able to predict malignant and benign neoplasms with an 90.41% accuracy after the hyper parameter tuning process. Conclusions: This study concludes that the above mentioned features (except skewness and GLCM homogeneity) are informative to identify and differentiate malignant from benign brain tumors. Moreover, they enable the development of a high-performance ML model that has the ability to assist in the decision-making steps of brain tumor diagnosis process, prior to attempting invasive diagnostic procedures, such as brain biopsies.

22 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SVSahan M. Vijithananda
Sahan M. Vijithananda
MJMohan L. Jayatilake
Mohan L. Jayatilake
TGTeresa C. Gonçalves
Teresa C. Gonçalves
LRLuis M. Rato
Luis M. Rato
BWBimali S. Weerakoon
Bimali S. Weerakoon
PHP. B. Hewavithana
P. B. Hewavithana
Apparent diffusion coefficient (ADC) of magnetic resonance imaging (MRI) is an indispensable imaging technique in clinical neuroimaging that quantitatively assesses the diffusivity of water molecules within tissues using diffusion-weighted imaging (DWI). This study focuses on developing a robust machine learning (ML) model to predict the aggressiveness of gliomas according to World Health Organization (WHO) grading by analyzing patients’ demographics, higher-order moments, and grey level co-occurrence matrix (GLCM) texture features of ADC. A population of 722 labeled MRI-ADC brain image slices from 88 human subjects was selected, where gliomas are labeled as glioblastoma multiforme (WHO-IV), high-grade glioma (WHO-III), and low-grade glioma (WHO I-II). Images were acquired using 3T-MR systems and a region of interest (ROI) was delineated manually over tumor areas. Skewness, kurtosis, and statistical texture features of GLCM (mean, variance, energy, entropy, contrast, homogeneity, correlation, prominence, and shade) were calculated using ADC values within ROI. The ANOVA f-test was utilized to select the best features to train an ML model. The data set was split into training (70%) and testing (30%) sets. The train set was fed into several ML algorithms and selected most promising ML algorithm using K-fold cross-validation. The hyper-parameters of the selected algorithm were optimized using random grid search technique. Finally, the performance of the developed model was assessed by calculating accuracy, precision, recall, and F1 values reported for the test set. According to the ANOVA f-test, three attributes; patient gender (1.48), GLCM energy (9.48), and correlation (13.86) that performed minimum scores were excluded from the dataset. Among the tested algorithms, the random forest classifier(0.8772 ± 0.0237) performed the highest mean-cross-validation score and selected to build the ML model which was able to predict tumor categories with an accuracy of 88.14% over the test set. The study concludes that the developed ML model using the above features except for patient gender, GLCM energy, and correlation, has high prediction accuracy in glioma grading. Therefore, the outcomes of this study enable to development of advanced tumor classification applications that assist in the decision-making process in a real-time clinical environment.

6 November 2024 in IEEE Access
Verified
Journal Article
Open access
Deshan KalupahanaDeshan Kalupahana
Deshan Kalupahana
Nipun Shantha KahatapitiyaNipun Shantha Kahatapitiya
Nipun Shantha Kahatapitiya
DKDilakshan Kamalathasan
Dilakshan Kamalathasan
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
BSBhagya Nathali Silva
Bhagya Nathali Silva
Udaya WijenayakeUdaya Wijenayake
Udaya Wijenayake
Optical Coherence Tomography (OCT) emerged as a technology for the detection of retinal disease. Owing to its excellent performance and ability to provide in-vivo high-resolution images, the popularity increased dramatically across various application domains. Consequently, OCT has been widely used in other branches of medical applications, i.e., oncology and otolaryngology, industry, and agriculture. Despite its widespread use, OCT image analysis is an inherently subjective, laborious, and time-intensive task that requires expertise. Deep learning (DL) stands as the current state-of-the-art method for image analysis. Hence, several research groups have directed their efforts toward incorporating DL algorithms with OCT imaging to reduce the time as well as the subjectivity. This article comprehensively reviews the principal technological advancements in DL methods applied across various OCT applications. Additionally, it explores the latest trends in developing DL methods for OCT, highlights their limitations, and discusses future opportunities in a comprehensive manner.

21 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Deshan KalupahanaDeshan Kalupahana
Deshan Kalupahana
Nipun Shantha KahatapitiyaNipun Shantha Kahatapitiya
Nipun Shantha Kahatapitiya
BSBhagya Nathali Silva
Bhagya Nathali Silva
JKJeehyun Kim
Jeehyun Kim
Mansik JeonMansik Jeon
Mansik Jeon
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
Circular leaf spot (CLS) disease poses a significant threat to persimmon cultivation, leading to substantial harvest reductions. Existing visual and destructive inspection methods suffer from subjectivity, limited accuracy, and considerable time consumption. This study presents an automated pre-identification method of the disease through a deep learning (DL) based pipeline integrated with optical coherence tomography (OCT), thereby addressing the highlighted issues with the existing methods. The investigation yielded promising outcomes by employing transfer learning with pre-trained DL models, specifically DenseNet-121 and VGG-16. The DenseNet-121 model excels in differentiating among three stages of CLS disease (healthy (H), apparently healthy (or healthy-infected (HI)), and infected (I)). The model achieved precision values of 0.7823 for class-H, 0.9005 for class-HI, and 0.7027 for class-I, supported by recall values of 0.8953 for class-HI and 0.8387 for class-I. Moreover, the performance of CLS detection was enhanced by a supplemental quality inspection model utilizing VGG-16, which attained an accuracy of 98.99% in discriminating between low-detail and high-detail images. Moreover, this study employed a combination of LAMP and A-scan for the dataset labeling process, significantly enhancing the accuracy of the models. Overall, this study underscores the potential of DL techniques integrated with OCT to enhance disease identification processes in agricultural settings, particularly in persimmon cultivation, by offering efficient and objective pre-identification of CLS and enabling early intervention and management strategies.

16 July 2019
Verified
Book Chapter
Closed access
SVSahan M. Vijithananda
Sahan M. Vijithananda
MJMohan L. Jayatilake
Mohan L. Jayatilake
BWBimali S. Weerakoon
Bimali S. Weerakoon
PWP. G. S. Wathsala
P. G. S. Wathsala
STS. Thevapriya
S. Thevapriya
TWThusitha K. Wijerathne
Thusitha K. Wijerathne

2 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
HMHana Sophie Mohamed
Hana Sophie Mohamed
SKSuresh Kalum Kathriarachchi
Suresh Kalum Kathriarachchi
Nipun Shantha KahatapitiyaNipun Shantha Kahatapitiya
Nipun Shantha Kahatapitiya
BSBhagya Nathali Silva
Bhagya Nathali Silva
Deshan KalupahanaDeshan Kalupahana
Deshan Kalupahana
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
Clinical fetal monitoring devices can only be operated by medical professionals and are overly costly, prone to detrimental false positives, and emit radiation. Thus, highly accurate, easily accessible, simplified, and cost-effective fetal monitoring devices have gained an enormous interest in obstetrics. In this study, a cost-effective and user-friendly wearable home fetal movement and distress detection device is developed and assessed for early-stage design progression by facilitating continuous, comfortable, and non-invasive monitoring of the fetus during the final trimester. The functionality of the developed prototype is mainly based on a microcontroller, a single accelerometer, and a specialized fetal phonocardiography (fPCG) acquisition board with a low-cost microphone. The developed system is capable of identifying fetal movement and monitors fetal heart rhythm owing to its considerable sensitivity. Further, the device includes a Global System for Mobile Communication (GSM)-based alert system for instant distress notifications to the mother, proxy, and emergency services. By incorporating digital signal processing, the system achieves zero false negatives in detecting fetal movements, which was validated against an open-source database. The acquired results clearly substantiated the efficacy of the fPCG acquisition board and alarm system, ensuring the prompt identification of fetal distress.