DG NORMASWANNA TAWASIL

Ms. DG NORMASWANNA TAWASIL

UNIVERSITI TEKNOLOGI MALAYSIA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in Buildings
Verified
Journal Article
Open access
PDF file
DG NORMASWANNA TAWASILDG NORMASWANNA TAWASIL
DG NORMASWANNA TAWASIL
EEYDZAH AMINUDINEEYDZAH AMINUDIN
EEYDZAH AMINUDIN
HLHasanah Shukor Lim
Hasanah Shukor Lim
NSNik Mohd Zaini Nik Soh
Nik Mohd Zaini Nik Soh
PAU CHUNG LENGPAU CHUNG LENG
PAU CHUNG LENG
MAMohd Hamdan Ahmad
Mohd Hamdan Ahmad
This paper evaluates, via a laboratory assessment, the physical properties (BS EN 323:1993, BS EN 324) and mechanical performance (BS EN 310:1993) of hybrid particleboards using agricultural wastes, namely coconut fibre and sawdust. The process begins with the preparation of the materials where they are sieved and retained with the 5-mm sieve and then oven-dried. The hybrid particleboard mixed with the addition of resin (urea formaldehyde) was sprayed and hot pressed. The hot press temperature was set at 180 °C, with the resin content of 8 wt.% and the design density of 650 kg/m3 used in producing the particleboard. The percentage/ratio of the composition of sawdust (SD) to coconut fibre (CF) varied ranging from 100SD:0CF to 70SD:30CF, 50SD:50CF, 30SD:70CF, and 0SD:100CF. Meanwhile, as for the thickness of the boards, it was categorised into three groups which are 16 mm, 20 mm, and 32 mm. The particleboards were conditioned to the room temperature for seven days before being tested for physical properties and mechanical performances. The results show that the most optimum composition of sawdust to coconut fibre is 0% sawdust to 100% coconut fibre (0SD:100CF) and the optimum thickness is 20 mm, where its density is 761.99 kg/m3, swelling thickness is 11.98%, and water absorption at 37.64%. With the modulus of elasticity of 1510 N/mm2, the modulus of rupture of 17.8 N/mm2, and the internal bonding of 1.08 N/mm2, they satisfied the universal standard of Particleboard Type P3 of BS EN 312:2010.

28 December 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
PAU CHUNG LENGPAU CHUNG LENG
PAU CHUNG LENG
Gabriel Hoh Teck LingGabriel Hoh Teck Ling
Gabriel Hoh Teck Ling
MAMohd Hamdan Ahmad
Mohd Hamdan Ahmad
DODilshan Remaz Ossen
Dilshan Remaz Ossen
EEYDZAH AMINUDINEEYDZAH AMINUDIN
EEYDZAH AMINUDIN
DG NORMASWANNA TAWASILDG NORMASWANNA TAWASIL
DG NORMASWANNA TAWASIL
The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.

1 May 2020 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
DG NORMASWANNA TAWASILDG NORMASWANNA TAWASIL
DG NORMASWANNA TAWASIL
EAEeydzah Aminudin
Eeydzah Aminudin
HLHasanah Abdul Shukor Lim
Hasanah Abdul Shukor Lim
Rozana ZakariaRozana Zakaria
Rozana Zakaria
HAHamdan bin Ahmad
Hamdan bin Ahmad
NSNik Mohd Zaini Nik Soh
Nik Mohd Zaini Nik Soh
Energy consumption has shown that residential building is among the main contributors of energy demand. Besides, the harsh climatic conditions have causes substantial amount of energy which contributes indirectly towards the impact on carbon emission to the nations. Hence, this research utilised the potential agricultural wastes materials that is potential for insulate the thermal building performance. The outer and inner surface temperature has been measured on selected seven (7) type of wastes material from agricultural and processing sector every 30 minutes from 0900hr to 1800hr for a day in order to determine the decrement factors (DF), average daily time-lag for heat transfer as one of the thermal insulation properties. Results on the time-lag for all selected potential waste materials as thermal insulation whereas sugarcane bagasse is the lowest 107.5 minutes, followed by both coffee grounds and coconut husk with 130 minutes and wood wool with 132.5 minutes. Meanwhile, empty fruit bunch, coconut fibre and pineapple leave with time-lag of 140 minutes, 142.5 minutes and 145 minutes respectively are the highest time-lag occurred. Generally, the lowest Tis is the better the thermal performance therefore, coconut fibre with smaller DF, larger LT but slightly higher Tis than EFB (32°C) which is 32.2 °C might be the suitable material use as thermal insulation.