Falls and fall-induced injuries are major global public health problems. Balance and gait disorders have been the second leading cause of falls. Inertial motion sensors and force sensors have been widely used to monitor both static and dynamic balance performance. Based on the detected performance, instant visual, auditory, electrotactile and vibrotactile biofeedback could be provided to augment the somatosensory input and enhance balance control. This review aims to synthesize the research examining the effect of biofeedback systems, with wearable inertial motion sensors and force sensors, on balance performance. Randomized and non-randomized clinical trials were included in this review. All studies were evaluated based on the methodological quality. Sample characteristics, device design and study characteristics were summarized. Most previous studies suggested that biofeedback devices were effective in enhancing static and dynamic balance in healthy young and older adults, and patients with balance and gait disorders. Attention should be paid to the choice of appropriate types of sensors and biofeedback for different intended purposes. Maximizing the computing capacity of the micro-processer, while minimizing the size of the electronic components, appears to be the future direction of optimizing the devices. Wearable balance-improving devices have their potential of serving as balance aids in daily life, which can be used indoors and outdoors.

27 September 2017 in Topics in Stroke Rehabilitation
Verified
Journal Article
Closed access
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
YZY.P. Zheng
Y.P. Zheng
WLWinson Lee
Winson Lee
Background: Patients with stroke walk with excessive foot inversion at the affected side, which may disturb their balance and gait. Objectives: This study aimed to investigate the effects of instant biofeedback of plantar force at the medial and lateral forefoot regions on gait and plantar foot loading in patients with stroke. Methods: A total of eight patients with hemiplegic stroke, who had flexible rearfoot varus deformity at the affected side, participated in this study. A vibrotactile biofeedback system was developed and evaluated. It analyzed forces at the medial and lateral forefeet, and instantly provided vibration clues when the plantar force at medial forefoot was less than a threshold. Each subject’s three-dimensional gait parameters and plantar-pressure distribution during walking were measured under two experimental conditions (sequence randomized): with and without the device turned on (Trial-registration number: ChiCTR-IPB-15006530 and HKCTR-1853). Results: Providing biofeedback significantly reduced the foot inversion and increased the mid-stance foot–floor contact area and medial midfoot plantar pressure of the affected limb, bringing the values of these parameters closer to those of the unaffected side. The biofeedback also significantly reduced the unaffected side’s excessive knee flexion and hip abduction. Conclusions: There were signs of improved foot loading characteristics and gait upon provision of instant vibrotactile biofeedback of plantar force. The positive results of this study further support the development of wearable biofeedback devices for improving gait of patients with stroke.

15 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
AWAnson Hong-Ping Wan
Anson Hong-Ping Wan
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
YZY.P. Zheng
Y.P. Zheng
WLWinson Lee
Winson Lee
Although biofeedback systems have been used to improve balance with success, they were confined to hospital training applications. Little attempt has been made to investigate the use of in-shoe plantar force measurement and wireless technology to turn hospital training biofeedback systems into wearable devices. This research developed a wearable biofeedback system which detects body sway by analyzing the plantar force and provides users with the corresponding haptic cues. The effects of this system were evaluated in thirty young and elderly subjects with simulated reduced foot sensation. Subjects performed a Romberg test under three conditions: (1) no socks, system turned-off; (2) wearing five layers of socks, system turned-off; (3) wearing five layers of socks, and system turned-on. Degree of body sway was investigated by computing the center of pressure (COP) movement measured by a floor-mounted force platform. Plantar tactile sensation was evaluated using a monofilament test. Wearing multiple socks significantly decreased the plantar tactile sensory input (p < 0.05), and increased the COP parameters (p < 0.017), indicating increased postural sway. After turning on the biofeedback system, the COP parameters decreased significantly (p < 0.017). The positive results of this study should inspire future development of wearable plantar force-based biofeedback systems for improving balance in people with sensory deficits.

18 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Ringo Tang-Long ZHURingo Tang-Long ZHU
Ringo Tang-Long ZHU
PLPei-Zhao Lyu
Pei-Zhao Lyu
SLShuai Li
Shuai Li
CTCheuk Ying Tong
Cheuk Ying Tong
YLYan To Ling
Yan To Ling
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
Making rapid and proper compensatory postural adjustments is vital to prevent falls and fall-related injuries. This study aimed to investigate how, especially how rapidly, the multiple lower-limb muscles and joints would respond to the unexpected standing balance perturbations. Unexpected waist-pull perturbations with small, medium and large magnitudes were delivered to twelve healthy young adults from the anterior, posterior, medial and lateral directions. Electromyographical (EMG) and mechanomyographical (MMG) responses of eight dominant-leg muscles (i.e., hip abductor/adductors, hip flexor/extensor, knee flexor/extensor, and ankle dorsiflexor/plantarflexors) together with the lower-limb joint angle, moment, and power data were recorded. The onset latencies, time to peak, peak values, and/or rate of change of these signals were analyzed. Statistical analysis revealed that: (1) agonist muscles resisting the delivered perturbation had faster activation than the antagonist muscles; (2) ankle muscles showed the largest rate of activation among eight muscles following both anteroposterior and mediolateral perturbations; (3) lower-limb joint moments that complied with the perturbation had faster increase; and (4) larger perturbation magnitude tended to evoke a faster response in muscle activities, but not necessarily in joint kinetics/kinematics. These findings provided insights regarding the underlying mechanism and lower-limb muscle activities to maintain reactive standing balance in healthy young adults.

7 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
YLYan To Ling
Yan To Ling
QSQueenie Tsung Kwan Shea
Queenie Tsung Kwan Shea
WLWang Like
Wang Like
XWXiao-Yun Wang
Xiao-Yun Wang
YZY.P. Zheng
Y.P. Zheng
Background: Motion capture and analyzing systems are essential for understanding locomotion. However, the existing devices are too cumbersome and can be used indoors only. A newly-developed wearable motion capture and measurement system with multiple sensors and ultrasound imaging was introduced in this study. Methods: In ten healthy participants, the changes in muscle area and activity of gastrocnemius, plantarflexion and dorsiflexion of right leg during walking were evaluated by the developed system and the Vicon system. The existence of significant changes in a gait cycle, comparison of the ankle kinetic data captured by the developed system and the Vicon system, and test-retest reliability (evaluated by the intraclass correlation coefficient, ICC) in each channel’s data captured by the developed system were examined. Results: Moderate to good test-retest reliability of various channels of the developed system (0.512 ≤ ICC ≤ 0.988, p < 0.05), significantly high correlation between the developed system and Vicon system in ankle joint angles (0.638R ≤ 0.707, p < 0.05), and significant changes in muscle activity of gastrocnemius during a gait cycle (p < 0.05) were found. Conclusion: A newly developed wearable motion capture and measurement system with ultrasound imaging that can accurately capture the motion of one leg was evaluated in this study, which paves the way towards real-time comprehensive evaluation of muscles and joint motions during different activities in both indoor and outdoor environments.

1 July 2016 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
AWAnson H. Wan
Anson H. Wan
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
MZMing Zhang
Ming Zhang
WLWinson Lee
Winson Lee