Background: Motion capture and analyzing systems are essential for understanding locomotion. However, the existing devices are too cumbersome and can be used indoors only. A newly-developed wearable motion capture and measurement system with multiple sensors and ultrasound imaging was introduced in this study. Methods: In ten healthy participants, the changes in muscle area and activity of gastrocnemius, plantarflexion and dorsiflexion of right leg during walking were evaluated by the developed system and the Vicon system. The existence of significant changes in a gait cycle, comparison of the ankle kinetic data captured by the developed system and the Vicon system, and test-retest reliability (evaluated by the intraclass correlation coefficient, ICC) in each channel’s data captured by the developed system were examined. Results: Moderate to good test-retest reliability of various channels of the developed system (0.512 ≤ ICC ≤ 0.988, p < 0.05), significantly high correlation between the developed system and Vicon system in ankle joint angles (0.638R ≤ 0.707, p < 0.05), and significant changes in muscle activity of gastrocnemius during a gait cycle (p < 0.05) were found. Conclusion: A newly developed wearable motion capture and measurement system with ultrasound imaging that can accurately capture the motion of one leg was evaluated in this study, which paves the way towards real-time comprehensive evaluation of muscles and joint motions during different activities in both indoor and outdoor environments.
Abnormal muscle tone and muscle weakness are related to gait asymmetry in stroke survivors. However, the internal muscle morphological changes that occur during walking remain unclear. To address this issue, this study investigated the muscle activity of the tibialis anterior (TA) and medial gastrocnemius (MG) of both the paretic and non-paretic sides during walking in nine stroke survivors, by simultaneously capturing electromyography (EMG), mechanomyography (MMG), and ultrasound images, and using a validated novel wearable ultrasound imaging and sensing system. Statistical analysis was performed to examine the test–retest reliability of the collected data, and both the main and interaction effects of each “side” (paretic vs. non-paretic) and “gait” factors, in stroke survivors. This study observed significantly good test–retest reliability in the collected data (0.794 ≤ ICC ≤ 0.985), and significant differences existed in both the side and gait factors of the average TA muscle thickness from ultrasound images, and in the gait factors of TA and MG muscle’s MMG and EMG signals (p < 0.05). The muscle morphological characteristics also appeared to be different between the paretic and non-paretic sides on ultrasound images. This study uncovered significantly different internal muscle contraction patterns between paretic and non-paretic sides during walking for TA (7.2% ± 1.6%) and MG (5.3% ± 4.9%) muscles in stroke survivors.
Transient elastography (TE), recommended by the WHO, is an established method for characterizing liver fibrosis via liver stiffness measurement (LSM). However, technical barriers remain towards point-of-care application, as conventional TE requires wired connections, possesses a bulky size, and lacks adequate imaging guidance for precise liver localization. In this work, we report the design, phantom validation, and clinical evaluation of a palm-sized TE system that enables simultaneous B-mode imaging and LSM. The performance of this system was validated experimentally using tissue-equivalent reference phantoms (1.45–75 kPa). Comparative studies against other liver elastography techniques, including conventional TE and two-dimensional shear wave elastography (2D-SWE), were performed to evaluate its reliability and validity in adults with various chronic liver diseases. Intra- and inter-operator reliability of LSM were established by an elastography expert and a novice. A good agreement was observed between the Young’s modulus reported by the phantom manufacturer and this system (bias: 1.1–8.6%). Among 121 patients, liver stiffness measured by this system and conventional TE were highly correlated (r = 0.975) and strongly agreed with each other (mean difference: −0.77 kPa). Inter-correlation of this system with conventional TE and 2D-SWE was observed. Excellent-to-good operator reliability was demonstrated in 60 patients (ICCs: 0.824–0.913). We demonstrated the feasibility of employing a fully integrated phased array probe for reliable and valid LSM, guided by real-time B-mode imaging of liver anatomy. This system represents the first technical advancement toward point-of-care liver fibrosis assessment. Its small footprint, along with B-mode guidance capability, improves examination efficiency and scales up screening for liver fibrosis.
Purpose. Considering that intraocular pressure (IOP) is an important confounding factor in corneal biomechanical evaluation, the notion of matching IOP should be introduced to eliminate any potential bias. This study aimed to assess the capability of a novel parameter set (NPS) derived from IOP-matched scenario to diagnose keratoconus. Methods. Seventy samples (training set; 35 keratoconus and 35 normal corneas; pairwise matching for IOP) were used to determine NPS by forward logistic regression. A large validation dataset comprising 62 matching samples (31 keratoconus and 31 normal corneas) and 203 unmatching samples (112 keratoconus and 91 normal corneas) was used to evaluate its clinical significance. To further assess its diagnosis capability, NPS was compared with the other two prior biomechanical indexes. Results. NPS was comprised of three biomechanical parameters, namely, DA Ratio Max 1mm (DRM1), the first applanation time (AT1), and an energy loading parameter (Eload). NPS was successfully applied to the validation dataset, with a higher accuracy of 96.8 and 95.6 in the IOP-matched and -unmatched scenarios, respectively. More surprisingly, accuracy of NPS was 95.5 in the combined validation, an improvement compared to the two prior biomechanical indexes. Conclusions. This is the first study taking IOP bias into consideration to determine a biomechanical parameter set. Our study shows that NPS indeed offers comparable performance in keratoconus diagnosis. Translational Relevance. Determining a parameter set after eliminating the influence from IOP is useful in revealing the essential differences between keratoconus and normal corneas and possibly facilitating further progress in keratoconus diagnosis.